9 August 2013 in Bulletin of Earthquake Engineering
On Wednesday 11th May 2011 at 6:47 pm (local time) a magnitude 5.1 Mw earthquake occurred 6 km northeast of Lorca with a depth of around 5 km. As a consequence of the shallow depth and the small epicentral distance, important damage was produced in several masonry constructions and even led to the collapse of one of them. Pieces of the facades of several buildings fell down onto the sidewalk, being one of the reasons for the killing of a total of 9 people. The objective of this paper is to describe and analyze the failure patterns observed in reinforced concrete frame buildings with masonry infill walls ranging from 3 to 8 floors in height. Structural as well as non-structural masonry walls suffered important damage that led to redistributions of forces causing in some cases the failure of columns. The importance of the interaction between the structural frames and the infill panels is analyzed by means of non-linear Finite Element Models. The resulting load levels are compared with the member capacities and the changes of the mechanical properties during the seismic event are described and discussed. In the light of the results obtained the observed failure patterns are explained. Some comments are stated concerning the adequacy of the numerical models that are usually used during the design phase for the seismic analysis.
1 November 2012 in Journal of Sound and Vibration
Underpasses are common in modern railway lines. Wildlife corridors and drainage conduits often fall into this category of partially buried structures. Their dynamic behavior has received far less attention than that of other structures such as bridges, but their large number makes their study an interesting challenge from the viewpoint of safety and cost savings. Here, we present a complete study of a culvert, including on-site measurements and numerical modeling. The studied structure belongs to the high-speed railway line linking Segovia and Valladolid in Spain. The line was opened to traffic in 2004. On-site measurements were performed for the structure by recording the dynamic response at selected points of the structure during the passage of high-speed trains at speeds ranging between 200 and 300 km/h. The measurements provide not only reference values suitable for model fitting, but also a good insight into the main features of the dynamic behavior of this structure. Finite element techniques were used to model the dynamic behavior of the structure and its key features. Special attention is paid to vertical accelerations, the values of which should be limited to avoid track instability according to Eurocode. This study furthers our understanding of the dynamic response of railway underpasses to train loads
12 November 2015 in Comptes Rendus Mécanique
Non-linear behavior of soils during a seismic event has a predominant role in current site response analysis. Soil response analysis consistently indicates that the stress–strain relationship of soils is non-linear and shows hysteresis. When focusing on forced response simulations, time integrations based on modal analysis are widely considered; however, parametric analysis, non-linear behavior and complex damping functions make difficult the online use of standard discretization strategies, e.g., those based on the use of finite element. In this paper, we propose a new harmonic analysis formulation, able to address forced response simulation of soils exhibiting their characteristic non-linear behavior. The solution can be evaluated in real-time from the offline construction of a parametric solution to the associated linearized problem within the Proper Generalized Decomposition framework.
2 April 2013 in Progress in Photovoltaics: Research and Applications
1 October 2016 in Engineering Structures
1 January 2017 in Engineering Structures