Yinghua Zou

Yinghua Zou

Auto-generated profile, based on publicly available information

Yinghua Zou

Department of Interventional Radiology and Vascular Surgery, Peking University First Hospital, Xicheng District, Beijing, China

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2019 in Journal of Minimally Invasive Gynecology
Verified
Journal Article
Closed access
LLLetao Lin
Letao Lin
HMHaocheng Ma
Haocheng Ma
JWJian Wang
Jian Wang
HGHaitao Guan
Haitao Guan
MYMin Yang
Min Yang
YZYinghua Zou
Yinghua Zou

21 March 2019 in Journal of International Medical Research
Verified
Journal Article
Open access
PDF file
LLLetao Lin
Letao Lin
XLXinfei Li
Xinfei Li
HGHaitao Guan
Haitao Guan
JWJian Wang
Jian Wang
XTXiaoqiang Tong
Xiaoqiang Tong
YZYinghua Zou
Yinghua Zou
Objective: The present study aimed to evaluate renal function, complications, and changes in tumor size after transarterial embolization for patients with renal angiomyolipomas. Methods: We performed a meta-analysis of transarterial embolization in patients with renal angiomyolipomas from January 1994 to April 2018. Endpoints of interest were the estimated glomerular filtration rate, serum creatinine levels, blood urea nitrogen levels, complications, and reduction of tumors. Results: A total of 30 studies comprising 653 patients were included. A total of 32.0% of patients were treated by urgent transarterial embolization for spontaneous ruptured renal angiomyolipomas. Other patients sought to relieve symptoms or received embolism prophylactically. The estimated glomerular filtration rate showed no significant difference between before and after embolization. In 363 patients with data on complications, post-embolization syndrome occurred most frequently (54.0%). Only 16 (4.4%) patients had major complications. The diameter of sporadic angiomyolipomas was reduced by a mean of 2.09 cm (95% confidence interval [CI], 0.73–3.45 cm; I 2 = 29.3%) and they were reduced in size by 30.0% (95% CI, 16.0%–44.0%; I 2 = 27.9%). Conclusions: Transarterial embolization of renal angiomyolipomas affects renal function preservation, with a low complication rate. Transarterial embolization is useful for sporadic and tuberous sclerosis complex-related angiomyolipomas.

22 December 2021 in International Journal of Hyperthermia
Verified
Journal Article
Open access
SCShoujin Cao
Shoujin Cao
YZYinghua Zou
Yinghua Zou
TLTianshi Lyu
Tianshi Lyu
ZFZeyang Fan
Zeyang Fan
HGHaitao Guan
Haitao Guan
JWJian WANG
Jian WANG
To compare the long-term outcomes of combined transarterial chemoembolization and radiofrequency ablation (TACE-RFA) with radiofrequency ablation (RFA) monotherapy for small (≤3 cm) hepatocellular ...

1 June 2017 in Medicine
Verified
Journal Article
Open access
PDF file
HGHaitao Guan
Haitao Guan
YZYinghua Zou
Yinghua Zou
YLYongxing Lv
Yongxing Lv
Chao WangChao Wang
Chao Wang
Perivascular epithelioid cell tumors (PEComas) are extremely rare mesenchymal entities with potentially malignant properties; the liver cases are not encountered frequently. Owing to themalignant potential, these tumors are treated by surgical methods to ensure total resection. In the present report, a case of liver PEComa treated by embolization combined with radiofrequency ablation (RFA) has been described. A 40-year-old female was admitted for the detection of a liver mass during an annual physical examination. The patient did not have any liver disease background, enhanced computed tomography (CT), and magnetic resonance revealed a huge mass in the right lobe. Pathology gave the diagnosis of PEComa, for disagreement of open surgery, a combination of transarterial embolization (TAE) and RFA were applied for treatment and the outcomes were acceptable, the patient was under follow-up to observe the long-term effect. Interventional procedures such as TAE and RFA are feasible and effective for such lesions and may serve as an alternate when resection is not indicated. Prospective studies are warranted to verify the long-term outcomes.

3 January 2019 in European Archives of Oto-Rhino-Laryngology
Verified
Journal Article
Closed access
PDF file
RPRenguang Pei
Renguang Pei
MYMin Yang
Min Yang
JWJian Wang
Jian Wang
XTXiaoqiang Tong
Xiaoqiang Tong
GWGuoxiang Wang
Guoxiang Wang
YZYinghua Zou
Yinghua Zou

18 April 2022 in Indian Journal of Surgery
Verified
Journal Article
Open access
PDF file
TLTianshi Lyu
Tianshi Lyu
SCShoujin Cao
Shoujin Cao
JWJian Wang
Jian Wang
SLSong Li
Song Li
XTXiaoqiang Tong
Xiaoqiang Tong
YZYinghua Zou
Yinghua Zou
Catheter rupture or displacement is a serious and rare complication of central venous catheterization, with an incidence of approximately 1%. Once the intravascular foreign body is found, it should be removed as soon as possible. This study investigated the safety and efficacy of endovascular techniques for the removal of intravascular foreign bodies. This was a retrospective analysis of 23 patients with intravascular foreign bodies admitted to our hospital from January 2009 to June 2019 summarizing the types and locations of foreign bodies and the removal techniques. Overall Twenty-three cases of intravascular foreign bodies were successfully treated with endovascular techniques, for a technical success rate of 100%. The types of foreign bodies included 14 infusion port catheters (60.9%), 6 peripherally inserted central catheters (26.1%), 2 temporary deep vein catheters (8.7%), and 1 intravenous stent (4.3%). The most common orientation of foreign body displacement was one end of the foreign body in the inferior vena cava and the other end in the right atrium (14/23, 60.9%). In terms of technique, all patients underwent removal procedures with only one venous access point. The operative time ranged from 6 to 153 min, with an average of 28.7 min. This study preliminarily demonstrates the safety and efficacy of percutaneous interventional intravascular foreign body removal. Endovascular techniques are minimally invasive and reliable and can be used to safely and effectively remove intravascular foreign bodies.