Yu Lei

Yu Lei

Auto-generated profile, based on publicly available information

Yu Lei

Department of Radiation Oncology, University of Nebraska Medical Center, 986861 Nebraska Medical Center, Omaha, 68198-7400, UNITED STATES

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

1 January 2020 in BioMed Research International
Verified
Journal Article
Open access
PDF file
JHJian Hu
Jian Hu
GHGuang Han
Guang Han
YLYu Lei
Yu Lei
XXXiming Xu
Ximing Xu
WGWei Ge
Wei Ge
XLXiangpan Li
Xiangpan Li
Introduction. This study is aimed at evaluating the dosimetric differences among target segmented planning (TSP), conventional 9‐field intensity modulated radiation therapy (9FIMRT) planning, and volumetric modulated arc therapy (VMAT) planning for postmastectomy radiotherapy of left‐sided breast cancer patients. Material and Methods. Fifteen left‐sided breast cancer patients who underwent radical mastectomy were enrolled. In TSP, the planning target volume (PTV) was divided into four regions (supra/infraclavicular, chest wall, external mammary region, and internal mammary region), and each individual PTV region was treated with respective fixed fields. Results. The VMAT plans showed superior to PTV dose conformity index (CI), homogeneity index (HI), protection of the ipsilateral lung, monitor units (MUs), and maximum dose (Dmax) to the contralateral breast compared with TSP and 9FIMRT plans. The TSP provided better protection for Dmean of the heart and left ventricle (p < 0.05). A dose for left anterior descending artery from the three techniques had no significant difference. Compared with the 9FIMRT plans, the V5Gy (%) and V10Gy (%) for the ipsilateral lung were significantly reduced with TSP and VMAT (p < 0.05). The V5Gy (%) and V10Gy (%) for the ipsilateral lung turned out to be similar between VMAT and TSP techniques. Conclusions. Our study indicates that VMAT should be a better choice of radiotherapy for left‐sided breast cancer patients after radical mastectomy. If VMAT is unavailable, 9FIMRT can achieve better CI and HI values and be more MU‐efficient compared with TSP; however, TSP can effectively reduce the low dose volume of the ipsilateral lungs and heart.

17 June 2016 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
DZDandan Zheng
Dandan Zheng
XZXiaofeng Zhu
Xiaofeng Zhu
QZQinghui Zhang
Qinghui Zhang
XLXiaoying Liang
Xiaoying Liang
WZWeining Zhen
Weining Zhen
CZChi Zhang
Chi Zhang
A challenge preventing routine clinical implementation of Monte Carlo (MC)-based lung SBRT is the difficulty of reinterpreting historical outcome data calculated with inaccurate dose algorithms, because the target dose was found to decrease to varying degrees when recalculated with MC. The large variability was previously found to be affected by factors such as tumour size, location, and lung density, usually through sub-group comparisons. We hereby conducted a pilot study to systematically and quantitatively analyze these patient factors and explore accurate target dose conversion models, so that large-scale historical outcome data can be correlated with more accurate MC dose without recalculation. Twenty-one patients that underwent SBRT for early-stage lung cancer were replanned with 6MV 360° dynamic conformal arcs using pencil-beam (PB) and recalculated with MC. The percent D95 difference (PB-MC) was calculated for the PTV and GTV. Using single linear regression, this difference was correlated with the following quantitative patient indices: maximum tumour diameter (MaxD); PTV and GTV volumes; minimum distance from tumour to soft tissue (dmin); and mean density and standard deviation of the PTV, GTV, PTV margin, lung, and 2 mm, 15 mm, 50 mm shells outside the PTV. Multiple linear regression and artificial neural network (ANN) were employed to model multiple factors and improve dose conversion accuracy. Single linear regression with PTV D95 deficiency identified the strongest correlation on mean-density (location) indices, weaker on lung density, and the weakest on size indices, with the following R2 values in decreasing orders: shell2mm (0.71), PTV (0.68), PTV margin (0.65), shell15mm (0.62), shell50mm (0.49), lung (0.40), dmin (0.22), GTV (0.19), MaxD (0.17), PTV volume (0.15), and GTV volume (0.08). A multiple linear regression model yielded the significance factor of 3.0E-7 using two independent features: mean density of shell2mm (P = 1.6E-7) and PTV volume (P = 0.006). A 4-feature ANN model slightly improved the modeling accuracy. Quantifiable density features were proposed, replacing simple central/peripheral location designation, which showed strong correlations with PB-to-MC target dose conversion magnitude, followed by lung density and target size. Density in the immediate outer and inner areas of the PTV showed the strongest correlations. A multiple linear regression model with one such feature and PTV volume established a high significance factor, improving dose conversion accuracy.

15 June 2019 in Journal of X-Ray Science and Technology
Verified
Journal Article
Closed access
PDF file
JPJinghui Pan
Jinghui Pan
DYDong-Dong Yu
Dong-Dong Yu
QSQibin Song
Qibin Song
CRChang-Li Ruan
Chang-Li Ruan
JFJingguo Fu
Jingguo Fu
GHGuang Han
Guang Han
OBJECTIVE: The skin marking method (SMM) and bow-form-ruler marking method (BFRM) are two commonly used patient marking methods in mainland China. This study aims to evaluate SMM and BFRM by comparing the inter-fraction setup errors from using these two methods together with vacuum cushion immobilization in patients underwent radiotherapy for different treatment sites. MATERIALS AND METHODS: Eighteen patients diagnosed with pelvic, abdominal and thoracic malignant tumors (with 6 patients per treatment site) were enrolled in this prospective study. All patients were immobilized with vacuum cushion. Each patient was marked by both SMM and BFRM before computed tomography (CT) simulation. Target location was verified by cone beam CT images with displacements assessed prior to each sampled treatment session. The localization errors in three translational and three rotational directions were recorded and analyzed. RESULTS: Images from 108 fractions in 18 patients produced 324 translational and 324 rotational comparisons for SMM and BFRM. The setup errors of all treatment sites showed no difference in two marking methods in any directions ( p > 0.05). In subgroups of treatment site analysis, SMM significantly lessened the lateral and yaw setup errors compared to BFRM in the pelvic sites (0.39±1.85 mm vs –1.28±1.13 mm, p < 0.01 and –0.19±0.59° vs –0.61±0.59°, p < 0.05). However, in the abdominal subgroup, BFRM was superior to SMM for reduced vertical errors (0.17±2.73 mm vs 2.28±3.16 mm, p < 0.05). For the underweight or obese patients (with Body Mass Index, BMI < 18.5 or BMI≥24), SMM resulted in less yaw errors compared to BFRM (–0.05±0.38° vs –0.43±0.48°, p < 0.05). No significant difference between SMM and BFRM in setup errors of normal weighted patients (18.5≤BMI < 24) was observed for all three studied treatment sites. CONCLUSIONS: This study shows no significant difference in patient setup errors for various treatment sites between SMM and BFRM in general. SMM may be suitable for the pelvic tumor and patients with BMI < 18.5 or BMI≥24, while BFRM is recommended for the abdominal tumor sites.

17 May 2021 in arXiv
Verified
Preprint
Open access
PDF file
YLYingbo Li
Yingbo Li
YDYucong Duan
Yucong Duan
ASAnamaria-Beatrice Spulber
Anamaria-Beatrice Spulber
HCHaoyang Che
Haoyang Che
Zakaria MaamarZakaria Maamar
Zakaria Maamar
YLYu Lei
Yu Lei
Artificial Intelligence has been a growth catalyst to our society and is cosidered across all idustries as a fundamental technology. However, its development has been limited to the signal processing domain that relies on the generated and collected data from other sensors. In recent research, concepts of Digital Artificial Intelligence and Physicial Artifical Intelligence have emerged and this can be considered a big step in the theoretical development of Artifical Intelligence. In this paper we explore the concept of Physicial Artifical Intelligence and propose two subdomains: Integrated Physicial Artifical Intelligence and Distributed Physicial Artifical Intelligence. The paper will also examine the trend and governance of Physicial Artifical Intelligence.

5 November 2024 in Cancers
Verified
Journal Article
Open access
PDF file
SWSHUO WANG
SHUO WANG
DBDarryl Belemlilga
Darryl Belemlilga
YLYu Lei
Yu Lei
AGApar Kishor Ganti
Apar Kishor Ganti
CLChi C. Lin
Chi C. Lin
SZSumin Zhou
Sumin Zhou
(1) Background: Advanced-stage lung cancer poses significant management challenges. The goal of this study was to identify crucial clinical and PET radiomics features that enable prognostic stratification for predicting outcomes. (2) Methods: PET radiomics features of the primary lung lesions were extracted from 99 patients with stage IVB NSCLC, and the robustness of these PET radiomics features was evaluated against uncertainties stemming from extraction parameters and contour variation. We trained three survival risk models (clinical, radiomics, and a composite) through a penalized Cox model framework. We also created a Balanced Random Forest classification predictive model, using the selected features, to predict 1-year survival. (3) Results: We identified 367 common PET radiomics features that exhibited robustness to perturbations introduced by contour variation and extraction parameters. Our findings indicated that both the radiomics and the composite model outperformed the clinical model in stratifying the risk for survival with statistical significance. In predicting 1-year survival, the radiomics model and the composite model also achieved better predicting accuracies compared to the clinical model. (4) Conclusions: Robust PET radiomics analysis successfully facilitated the stratification of patient risk for survival outcomes and predicted 1-year survival in stage IVB NSCLC.