1 March 2023 in The Astrophysical Journal
The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) sounding rocket experiment launched on 2021 July 30 from the White Sands Missile Range in New Mexico. MaGIXS is a unique solar observing telescope developed to capture X-ray spectral images of coronal active regions in the 6–24 Å wavelength range. Its novel design takes advantage of recent technological advances related to fabricating and optimizing X-ray optical systems, as well as breakthroughs in inversion methodologies necessary to create spectrally pure maps from overlapping spectral images. MaGIXS is the first instrument of its kind to provide spatially resolved soft X-ray spectra across a wide field of view. The plasma diagnostics available in this spectral regime make this instrument a powerful tool for probing solar coronal heating. This paper presents details from the first MaGIXS flight, the captured observations, the data processing and inversion techniques, and the first science results.
1 August 2022 in The Astrophysical Journal
ABAlexander R. Bruccoleri
+9
Arcus is a proposed Explorer Class soft X-ray grating spectrometer. It aims to explore cosmic feedback by mapping hot gases within and between galaxies and galaxy clusters and characterizing jets and winds from supermassive black holes and to investigate the dynamics of protoplanetary disks and stellar accretion. Arcus features 12 m focal-length grazing-incidence silicon pore optics (SPO) developed for the Athena mission. Critical-angle transmission (CAT) gratings efficiently disperse high diffraction orders onto CCDs. We report new and improved X-ray performance results for Arcus-like CAT gratings, including a record resolving power for two coaligned CAT gratings. Multiple Arcus prototype grating facets were illuminated by an SPO at the PANTER facility. The facets consist of 32 × 32.5 mm2 patterned silicon membranes, bonded to metal frames. The bonding angle is adjusted according to the measured average tilt angle of the grating bars in the membrane. Two simultaneously illuminated facets show a minor broadening of the Al-K
α
doublet in the 18th and 21st orders with the best-fit record effective resolving power of (3σ), about three to four times the Arcus requirement. We measured the diffraction efficiency of quasi-fully illuminated gratings at O-K wavelengths in orders 4–7 in an Arcus-like configuration and compare results with synchrotron spot measurements. After corrections for geometrical effects and bremsstrahlung continuum, we find agreement between full and spot illumination at the two different facilities, as well as with the models used for Arcus effective area predictions. We find that these flight-like gratings meet the diffraction efficiency and greatly exceed the resolving power Arcus requires.
19 March 2018 in Journal of Astronomical Telescopes, Instruments, and Systems
Thin x-ray optics with high angular resolution (≤ 0.5 arcsec) over a wide field of view enable the study of a number of astrophysically important topics and feature prominently in Lynx, a next-generation x-ray observatory concept currently under NASA study. In an effort to address this technology need, piezoelectrically adjustable, thin mirror segments capable of figure correction after mounting and on-orbit are under development. We report on the fabrication and characterization of an adjustable cylindrical slumped glass optic. This optic has realized 100% piezoelectric cell yield and employs lithographically patterned traces and anisotropic conductive film connections to address the piezoelectric cells. In addition, the measured responses of the piezoelectric cells are found to be in good agreement with finite-element analysis models. While the optic as manufactured is outside the range of absolute figure correction, simulated corrections using the measured responses of the piezoelectric cells are found to improve 5 to 10 arcsec mirrors to 1 to 3 arcsec [half-power diameter (HPD), single reflection at 1 keV]. Moreover, a measured relative figure change which would correct the figure of a representative slumped glass piece from 6.7 to 1.2 arcsec HPD is empirically demonstrated. We employ finite-element analysis-modeled influence functions to understand the current frequency limitations of the correction algorithm employed and identify a path toward achieving subarcsecond corrections.
23 March 2019 in Journal of Astronomical Telescopes, Instruments, and Systems
Piezoelectric adjustable x-ray optics use magnetron sputtered thin film coatings on both sides of a thin curved glass substrate. To produce an optic suitable for a mission requiring high-angular resolution like “Lynx,” the integrated stresses (stress × thickness) of films on both sides of the optic must be approximately equal. Thus, understanding how sputtered film thickness distributions change for convex and concave curved substrates is necessary. To address this, thickness distributions of piezoelectric Pb0.995(Zr0.52Ti0.48)0.99Nb0.01O3 films are studied on flat, convex, and concave cylindrical substrates with a 220-mm radius of curvature. A mathematical model of the film thickness distribution is derived based on the geometric properties of the sputter tool and the substrate, and film thicknesses deposited with a commercially available sputtering tool are measured with spectroscopic ellipsometry. Experiment and modeled results for flat and convex curved substrates demonstrate good agreement, with average relative thickness distribution difference of 0.19% and −0.10% respectively, and a higher average difference of 1.4% for concave substrates. The calculated relative thickness distributions are applied to the convex and concave sides of a finite-element analysis (FEA) model of an adjustable x-ray optic prototype. The FEA model shows that, left uncorrected, the relative film thickness variation will yield an optic with an optical performance of 2.6 arc sec half power diameter (HPD) at 1 keV. However, the mirror figure can be corrected to diffraction-limited performance (0.3 arc sec HPD) using the piezoelectric adjusters, suggesting that the tolerances for applying a balanced integrated stress on both sides of a mirror are alleviated for adjustable x-ray optics as compared to traditional static x-ray mirrors. Furthermore, the piezoelectric adjusters will also allow changes in mirror figure over the telescope lifetime due to drift in the stress states of the x-ray surfaces to be corrected on orbit.
30 September 2024 in Journal of Astronomical Telescopes, Instruments, and Systems
ABAlexander R. Bruccoleri
+3
The Arcus Probe mission concept has been submitted as an Astrophysics Probe Explorer candidate. It features two co-aligned high-resolution grating spectrometers: one for the soft X-ray band and one for the far ultraviolet. Together, these instruments can provide unprecedented performance to address important key questions about the structure and dynamics of our universe across a large range of length scales. The X-ray spectrometer consists of four parallel optical channels, each featuring an X-ray telescope with a fixed array of 216 lightweight, high-efficiency, blazed transmission gratings, and two charge-coupled device readout arrays. Average spectral resolving power λ/Δλ>2500 (3500 expected) across the 12 to 50 Å band and combined effective area >350 cm2 (>470 cm2 expected) near OVII wavelengths are predicted, based on the measured X-ray performance of the spectrometer prototypes and detailed ray trace modeling. We describe the optical and structural design of the grating arrays, from the macroscopic grating petals to the nanoscale gratings bars, grating fabrication, alignment, and X-ray testing. Recent X-ray diffraction efficiency results from chemically thinned grating bars are presented and show performance above mission assumptions.