Adiabatic expansion of a warm dense Ti plasma has been observed after isochoric heating of a -thick Ti foil with an -ns-long intense relativistic electron bunch at an energy of 19.8 MeV and a current of 1.7 kA. The expansion fits well with the analytical point-source solution. After 10 J is deposited and the plasma rapidly expands out of the warm dense phase, a stable degenerate plasma with is measured for ns. This is the first temporal measurement of the generation and adiabatic expansion of a large volume of warm dense plasma isochorically heated by intense monochromatic electrons. The suite of diagnostics is presented, which includes time-resolved plasma plume expansion measurements on a single shot, visible spectroscopy measurements of the emission and absorption spectrum, measurements of the beam distribution, and plans for the future.
A 100-μm-thick Cu foil is isochorically heated by a ∼100-ns-long electron bunch with an energy of 19.8 MeV and current of 1.7 kA to Te > 1 eV. After 100 ns of heating and 20 ns of expansion, the plasma exhibits a stable, quiescent temperature and density distribution for >200 ns. Several intense Cu-I emission lines are observed after ∼20 J of electron beam energy is deposited. These lines have well known Stark widths providing a direct measurement of ne. The Los Alamos ATOMIC code [Magee et al., AIP Conf. Proc. 2004, 168–179 and Hakel et al., J. Quant. Spectrosc. Radiat. Transfer 99, 265 (2006)] was run in local-thermodynamic-equilibrium mode to estimate Te and ne. Spatially and temporally resolved measurements are presented in both the vertical and horizontal directions adjacent to the foil indicating temperatures >1 eV and densities ranging from 1–3 × 1017 cm−3 after expansion and cooling.
Excess emission has been observed from velvet cathodes with total emission times >150 ns. In this diode experiment, we produce a sub-relativistic electron beam with the ability to consistently change γ from 1.2 to 1.5 and β = 0.5–0.75. Electron emission in this particular diode geometry requires electric fields >40 kV/cm. The current increases at steady rates >0.05 A/ns after the head of the pulse, indicating an expansion of the emission surface and reduction in the effective AK gap. Small transients of excess emission (or arcs) are consistently observed for current pulses exceeding 150 ns. The excess emission results in beam loaded levels ≥10 kV on the diode voltage. The effects described here are compounded as diode voltage is increased. The principal objective of these experiments is to quantify electric field emission thresholds, current ramps, excess emission delays, effective beam loading, and impedance collapse.
An array of photon diagnostics has been deployed on a high power relativistic electron beam diode. Electrons are extracted through a 17.8 cm diode from the surface discharge of a carbon fiber velvet cathode with a nominal diode voltage of 3.8 MV. V4 and detected photon counts of nearly 106 at a radial distance of 1 m which corresponds to dose ∼40 μrad at 1 m.