Natural ventilation associated with a mechanical fan is a feasible strategy to enhance thermal acceptability in warm weather. The ASHRAE-55 provides the increase for operative temperature proportional to the increase in air speed while maintaining thermal comfort. Conversely, the range of informed values is limited and little guidance for mechanical fans is provided. This work explores the relationship between operative temperature and air speed produced by ceiling fans, and the effectiveness to deliver thermal comfort for a wider range of values. The research method comprises transient computer fluid dynamics simulations coupled with a thermal sensation model and is divided into two stages: a calibration exercise and a parametrical investigation. Three matrices are presented for a range of operative temperatures (21.0–36.0 °C) and air speeds (0–2.5 m/s) for: Dynamic Thermal Sensation (DTS) (a computer-based seven-point index), Predicted Percentage of Dissatisfied, and potential Cooling Effect. When compared to the Predicted Mean Vote, the DTS overestimates thermal comfort for temperatures under 28.0 °C with increased air speed and overestimates discomfort for temperatures above 31.0 °C, even with increased air speed. Agreement is found between both scales for 28.0–31.0 °C, defining a range for the effective use of ceiling fans to provide thermal comfort under warm weather conditions.
Improving indoor environment quality and making urban centres in tropical regions more sustainable has become a challenge for which computational models for the prediction of thermal sensation for naturally ventilated buildings (NVBs) have major role to play. This work performed analysis on thermal sensation for non-residential NVBs located in Brazilian tropical warm-humid climate and tested the effectiveness of suggested adaptive behaviours to mitigate warm thermal sensation. The research method utilized transient computational fluid dynamics models coupled with a dynamic model for human thermophysiology to predict thermal sensation. The calculated results were validated with comparison with benchmark values from questionnaires and from field measurements. The calculated results for dynamic thermal sensation (DTS) seven-point scale showed higher agreement with the thermal sensation vote than with the predicted mean vote. The test for the suggested adaptive behaviours considered reducing clothing insulation values from 0.18 to 0.32 clo (reducing DTS from 0.1 to 0.9), increasing the air speed in 0.9 m/s (reducing DTS from 0.1 to 0.9), and applying both suggestions together (reducing DTS from 0.1 to 1.3) for five scenarios with operative temperatures spanning 34.5–24.0 °C. Results quantified the tested adaptive behaviours’ efficiency showing applicability to improve thermal sensation from slightly-warm to neutral.
O objetivo desse artigo é apresentar as características gerais de uma nova metodologia para planejamento energético urbano, detalhando os procedimentos para integração de condicionantes de morfologia urbana, que constitui a primeira etapa de aplicação metodológica. Esta abordagem é inovadora e focada na integração de estratégias e soluções em morfologia e mobilidade urbanas, edifícios, energia e meio ambiente para planejamento de áreas em desenvolvimento urbano, novas ou a serem requalificadas, na escala de distritos, bairros e unidades de vizinhança. A análise dos resultados da aplicação metodológica no caso da operação urbana Água Branca indicou que a ocupação urbana por edificações e as densidades construída e populacional necessitavam ser compatibilizadas com a área livre requerida ao adequado dimensionamento da seção viária, no que tange a aspectos de climatologia e de provimento de infraestrutura e demanda para mobilidade urbana. Esta era uma premissa para o aproveitamento da luz e da energia solar em edificações e para que o sistema de transporte urbano fosse mais funcional e energeticamente mais eficiente.