5 June 2025 in Knee Surgery, Sports Traumatology, Arthroscopy
15 October 2025 in Knee Surgery, Sports Traumatology, Arthroscopy
17 February 2026 in Revista Española de Cirugía Ortopédica y Traumatología
The primary objective is to analyze the distribution of three femoral anatomical parameters in a Spanish osteoarthritic population using CT-based measurements: (1) anatomical-mechanical axis (AA-MA), (2) posterior condylar-transepicondylar axis (PCA-TEA) and (3) lateral distal femoral angle (LDFA). The secondary objective is to assess the surgical relevance of these findings in TKA. It is a multicentric cross-sectional observational study. Preoperative CT-scans of 318 patients from a Spanish cohort were analyzed to determine AA-MA, PCA-TEA and LDFA. Then, femoral implant positioning was simulated as 5° of valgus from the AA and 3° of external rotation from the PCA. For each patient, this simulated positioning was compared to the theoretical mechanical alignment target. Finally, the native femoral JLO (LDFA) of each patient was compared to the mechanical alignment target (90°). Mean AA-MA relationship was 6.0°±0.9°, mean PCA-TEA angle was 3.1°±1.8° and mean native LDFA was 87.3°±2.9°. Positioning the femoral component systematically at 5° of valgus from the AA and 3° of external rotation from the PCA would result in 74.7% of implants being placed in varus and 46.1% in internal rotation from the TEA. Moreover, mechanically alignment would produce a more varus femoral JLO than the native LDFA in 78.1% of patients. There is considerable variability in femoral anatomy within the osteoarthritic Spanish population. The 6.7% of patients had AA-MA values outside the 5-7° range. The 41.8% of patients showed PCA-TEA angles smaller than 2° or greater that 4°. The 30.6% of LDFA were outside the 85-90° interval. Simulating a femoral component positioned using only AA and PCA references was associated with deviations from the intended mechanical alignment, most commonly resulting in varus deviation and internal rotation from the TEA.
1 April 2026 in Journal of Experimental Orthopaedics
Purpose: Intraoperative extension deficiency (IED) may arise after trial component implantation during total knee arthroplasty (TKA), a condition conceptually distinct from preoperative fixed flexion contracture (FFC). This study utilised a robotic system to quantify the incremental mechanical effect of sequential surgical actions—posterior capsule release (PCR), posterior cruciate ligament (PCL) excision and incremental distal femoral resections—to correct IED. A secondary objective was to evaluate their impact on manually assessed mediolateral laxity. Methods: Twenty‐nine robotic TKAs were performed on 15 fresh‐frozen cadaveric specimens. Nineteen knees presented with IED. All knees underwent PCR as the initial corrective manoeuvre. Subsequently, a quasi‐experimental design based on laterality was employed to evaluate two sequences: right knees underwent PCL excision followed by up to four 1‐mm distal femoral recuts; left knees followed the reverse order. Extension gains and manually assessed mediolateral laxities were recorded after each step. Results: Baseline IED averaged 6.6° ± 4.9°. Posterior capsule release corrected IED in 36.8% of the knees, yielding a mean extension gain of 1.68° ± 1.11°. The mechanical impact of distal femoral resections varied depending on PCL status: when the PCL remained intact, distal femoral recuts produced a substantial mean gain of 4.3° ± 0.6° per millimetre; however, following PCL excision, the gain per millimetre decreased to 2.8° ± 0.8°. PCL excision alone improved extension by a mean of 1.1° ± 1.3°. No significant changes in manually assessed mediolateral laxity at 0° and 90° of flexion were observed across manoeuvres. Conclusions: Robotic quantification demonstrates that the mechanical effectiveness of distal femoral resection is significantly enhanced by an intact PCL. While PCR is an impactful initial step for mild IED, distal femoral recuts provide greater extension gains. These objective data provide the foundation for a structured strategy to guide the intraoperative management of IED in both robotic and conventional TKA. Level of Evidence: N/A (cadaveric).
25 September 2025 in Scientific Reports
JMJosep Maria Muñoz-Vives
This ex-vivo study evaluated the tensile strength required for vascular occlusion using vessel loops on human femoral arterie and porcine aortic arteries. Temporary vascular occlusion is critical in many interventions, yet research on the tensile strength needed for effective occlusion with vessel loops is limited. Using an electronic-mechanical instrument, tensile strength in grams was measured across various sizes of Dormoloop vessel loops. The study compared the Potts loop and Rummel tourniquet techniques, revealing significant differences in the tensile strength required for occlusion. The Potts loop technique required a mean tensile strength of 305.75 g (± 106.07), while the Rummel tourniquet technique required 564.50 g (± 139.81), with a statistically significant difference (p = 0.027). All experiments achieved flow occlusion, demonstrating that the Potts loop technique requires less tensile strength, potentially resulting in less trauma during occlusion. These findings suggest that the choice of occlusion technique can impact the tensile force needed, with clinical implications that warrant further investigation, including studies with larger sample sizes and microscopic analyses to assess tissue trauma.
20 October 2026 in Revista Española de Cirugía Ortopédica y Traumatología