8 January 2025 in Indoor Air
This study developed and evaluated an optimal ventilation strategy for variable air volume (VAV) systems, targeting carbon dioxide (CO 2 ) and particulate matter less than 2.5 μ m in diameter (PM 2.5 ) concentrations. The strategy integrates system‐level demand‐controlled ventilation (DCV) based on real‐time occupancy data and zone‐level predictive control using indoor air quality (IAQ) prediction models. By predicting indoor CO 2 and PM 2.5 levels for the subsequent time step and dynamically adjusting control priorities, optimal airflow is determined. A co‐simulation model integrating EnergyPlus, CONTAM, and Python was employed for model training and testing. The proposed strategy was compared with on–off control, CO 2 predictive control, and PM 2.5 predictive control, demonstrating superior prediction accuracy and stable IAQ maintenance. The optimal ventilation strategy achieved the highest performance, maintaining CO 2 and PM 2.5 levels below their respective upper limits of 100% and 97.33% of the time. Although this strategy resulted in slightly higher energy consumption compared to the other control algorithms due to its multivariable control approach, it effectively maintained IAQ standards. This method simplifies development and maintenance by circumventing the need for complex optimization, providing a flexible and cost‐effective solution for IAQ management. Future research will focus on developing integrated VAV system control strategies that ensure comfort year‐round, addressing both energy efficiency and thermal comfort.
1 January 2026 in Indoor Air
Improvements in the indoor environment at schools are required due to the long periods of time spent in school facilities by children, who are particularly vulnerable to poor indoor air quality (IAQ). This study thus developed an AI‐based model predictive control algorithm (MPCA) for an outdoor air‐based energy recovery ventilation (ERV) system and evaluated its performance. The MPCA was based on artificial neural networks that predicted the particulate matter (PM) concentration, carbon dioxide (CO 2 ) levels, and temperature to achieve real‐time IAQ control. This algorithm was employed in an elementary school facility, and its performance was empirically compared with a rule‐based algorithm and occupant discretionary control (ODC). All three methods were able to improve the IAQ, with the proposed MPCA outperforming the rule‐based algorithm by maintaining a 21% lower PM 2.5 concentration and 7% lower CO 2 concentration. In addition, ODC required 2.4–2.5 times higher energy consumption than the other control methods, whereas the MPCA achieved a 5.7% reduction in energy consumption compared with the rule‐based algorithm. Therefore, the MPCA developed in this study is capable of predictive IAQ control for ERV systems and requires less energy than conventional methods, demonstrating its potential to effectively improve the IAQ of school facilities.