20 July 2020 in Physical Review Applied
We present a method of optical magnetometry with parts-per-billion resolution that is able to detect biomagnetic signals generated from the human brain and heart in Earth’s ambient environment. Our magnetically silent sensors measure the total magnetic field by detecting the free-precession frequency in a highly spin-polarized alkali-metal vapor. A first-order gradiometer is formed from two magnetometers that are separated by a 3-cm baseline. Our gradiometer operates from a laptop consuming 5 W over a USB port, enabled by state-of-the-art microfabricated alkali-vapor cells, advanced thermal insulation, custom electronics, and compact lasers within the sensor head. The gradiometer has a sensitivity of 16 outdoors, which we use to detect neuronal electrical currents and magnetic cardiography signals. Recording of neuronal magnetic fields is one of a few available methods for noninvasive functional brain imaging that usually requires extensive magnetic shielding and other infrastructure. This work demonstrates the possibility of a dense array of portable biomagnetic sensors that are deployable in a variety of natural environments.
2 March 2018 in Science Advances
We experimentally simulate a quantum-mechanical particle interacting with knotted electromagnetic fields.
6 January 2021 in Physical Review Applied
We describe a direct gradiometer using optical pumping with opposite circular polarization in two atomic ensembles within a single multipass cell. A far-detuned probe laser undergoes a near-zero paramagnetic Faraday rotation due to the intrinsic subtraction of two contributions exceeding 3.5 rad from the highly polarized ensembles. We develop analysis methods for the direct gradiometer signal and measure a gradiometer sensitivity of 10.1 . We also demonstrate that our multipass design, in addition to increasing the optical depth, provides a fundamental advantage due to the significantly reduced effect of atomic diffusion on the spin-noise time-correlation, in excellent agreement with the theoretical estimate.
12 August 2022 in Physical Review Applied
We describe a magnetic gradiometer that operates at finite fields and uses an intense pulsed laser to polarize a atomic ensemble and a compact vertical-cavity surface-emitting laser probe laser to detect paramagnetic Faraday rotation in a single multipass cell. We report differential magnetic sensitivity of , corresponding to gradiometer sensitivity of with a baseline, over a broad dynamic range, including Earth’s field magnitude and a common-mode rejection ratio higher than . We also observe a nearly quantum-noise-limited behavior of the gradiometer by comparing the experimental standard deviation of the estimated frequency difference against the Cramér-Rao lower bound in the presence of white photon shot-noise, atomic spin noise, and diffusion.
4 June 2021 in Physical Review A
Alkali-metal atomic magnetometers suffer from heading errors in geomagnetic fields as the measured magnetic field depends on the orientation of the sensor with respect to the field. In addition to the nonlinear Zeeman splitting, the difference between Zeeman resonances in the two hyperfine ground states can also generate heading errors depending on initial spin polarization. We examine heading errors in an all-optical scalar magnetometer that uses free precession of polarized atoms by varying the direction and magnitude of the magnetic field at different spin-polarization regimes. In the high-polarization limit where the lower hyperfine ground state is almost depopulated, we show that heading errors can be corrected with an analytical expression, reducing the errors by up to two orders of magnitude in earth's field. We also verify the linearity of the measured Zeeman precession frequency with the magnetic field. With lower spin polarization, we find that the splitting of the Zeeman resonances for the two hyperfine states causes beating in the precession signals and nonlinearity of the measured precession frequency with the magnetic field. We correct for the frequency shifts by using the unique probe geometry where two orthogonal probe beams measure opposite relative phases between the two hyperfine states during the spin precession.
5 February 2025 in Nature Communications
We introduce a vector atomic magnetometer that employs a fast-rotating magnetic field applied to a pulsed 87Rb scalar atomic magnetometer. This approach enables simultaneous measurements of the total magnetic field and its two polar angles relative to the rotation plane. Operating in gradiometer mode, the magnetometer achieves a total field gradient sensitivity of 35 $${{{\rm{fT}}}}/\sqrt{{{{\rm{Hz}}}}}$$ (0.7 parts per billion) and angular resolutions of 6 $${{{\rm{nrad}}}}/\sqrt{{{{\rm{Hz}}}}}$$ at a 50 μT Earth field strength. The noise spectra remain flat down to 1 Hz and 0.1 Hz, respectively. Here we show that this method overcomes several metrological challenges commonly faced by vector magnetometers and gradiometers. We propose a unique peak-altering modulation technique to mitigate systematic effects, including a newly identified dynamic heading error. Additionally, we establish the fundamental sensitivity limits of the sensor, demonstrating that its vector sensitivity approaches scalar sensitivity while preserving the inherent accuracy and calibration benefits of scalar sensors. This high-dynamic-range, ultrahigh-resolution magnetometer offers exceptional versatility for diverse applications.