Yong Fu

Yong Fu

Auto-generated profile, based on publicly available information

Yong Fu

Department of Electrical and Computer Engineering, Mississippi State University, Starkville, MS, USA

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 May 2017 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
CQChen Qi
Chen Qi
KWKeyou Wang
Keyou Wang
YFYong Fu
Yong Fu
GLGuo-Jie Li
Guo-Jie Li
BHBei Han
Bei Han
TPTianjiao Pu
Tianjiao Pu
In an AC/DC hybrid distribution grid (AC/DC HDG), different AC distribution grids are connected through a voltage source converter (VSC) based DC grid to operate the entire system in a secure and economic manner. This paper presents a decentralized optimal operation approach for running AC/DC HDG which can either work individually or collaborate with each other. Using the analytical target cascading (ATC) approach, a three-level hierarchy consisting of DC grids, VSC stations and AC grids, is formulated to decompose the operation problem of AC/DC HDG. The obtained subproblems for these grid levels, as well as the interactions between them, are modeled and solved with a nested solution process. The simulation results show the effectiveness of the proposed decentralized approach.

18 May 2018 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
MKMojtaba Khanabadi
Mojtaba Khanabadi
YFYong Fu
Yong Fu
CLCong Liu
Cong Liu
Independent system operators (ISOs) are responsible for the secure and economic operation of the power systems. Accordingly, ISOs should solve an optimal power flow to minimize the operating cost of a system while meeting the system's security constraints. However, transmission congestion could drastically limit more economical generating units from being dispatched in the power system operation. In this paper, a decentralized transmission switching is introduced in the operation of multi-area power systems to manage the congestion both on regional transmission lines and tie lines while considering credible contingencies. Our proposed methodology relies on a decentralized optimization methodology. Thus, regional control centers in areas would be able to locally manage the congestion within their regional networks as well as tie lines which connect them to their neighboring areas. In order to test the effectiveness of the proposed method, several testing systems are studied in this paper.

9 January 2023 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
CZChenxu Zhang
Chenxu Zhang
YFYong Fu
Yong Fu
The uncertainty of electricity prices poses a challenge to all market participants as their decisions highly depend on the accuracy of price forecasts. Prediction intervals become an efficient method to quantify the uncertainties that reside in electricity price forecasts. In this paper, we propose a probabilistic electricity price forecast with optimal prediction interval method that considers both reliability and sharpness requirements. Taking reliability and sharpness into account, we ensure the prediction interval has a narrow width without sacrificing reliability. In the proposed method, the quantile regression is utilized to estimate the upper and lower bounds of the prediction intervals to avoid electricity price distribution assumption. In addition, the extreme learning machine (ELM) method is embedded in the forecast method to capture the nonlinear relationship within price data, and its tuning parameters are optimized using the augmented Lagrangian relaxation method in this paper. The effectiveness of the proposed probabilistic forecast method is demonstrated using data from various electricity markets.

26 June 2017 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
MKMojtaba Khanabadi
Mojtaba Khanabadi
YFYong Fu
Yong Fu
LGLin Gong
Lin Gong
Multiarea power system operation/coordination is used to increase the reliability of the interconnected power grids and maintain the consistency of the price across the integrated power systems. However, the implementation of this coordinated operation is facing challenges due to increase in size and complexity of the modern power systems, high penetration of the volatile renewable energy, and interdependence issues among various power systems. To address these concerns, this paper presents a fully parallel decision-making approach for the day-ahead scheduling of interconnected power systems with large-scale wind power integration while respecting the information privacy between different systems/areas. In the proposed parallel approach, each system/area solves its day-ahead scheduling problem along with its local subproblems for different wind generations' scenarios, and sends its equivalent (or processed) boundary information to other systems/areas. The proposed inter-regional coordination among systems/areas and intra-regional coordination between scenarios in each system/area will continue until the tie-line power flows and the generation outputs of generating units get converged. The modified IEEE 118-bus testing system is used in this paper to show the effectiveness of the proposed approach.

3 March 2021 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
YYYujie Yin
Yujie Yin
YFYong Fu
Yong Fu
ZZZhiying Zhang
Zhiying Zhang
AZAmin Zamani
Amin Zamani
Protection of microgrids at the Point of Interconnection (POI) is a challenging task. Particularly, single-line-to-ground (SLG) faults on interconnection lines are difficult to detect using the fault current detection relays if the microgrid is ungrounded at utility side of its interconnection transformer; such microgrid contributes very low fault current, which disappears once the utility feeder breaker opens. Other common schemes for protection of microgrid interconnection line against SLG faults include Direct Transfer Trip (DTT) and over-voltage relay (59G). The main challenges associated with these methods are installation and maintenance costs of high-speed communication system, sensitivity of relay settings, and delayed fault clearing time due to selectivity requirements. To address such concerns, this paper proposes the use of a distance relay at the microgrid/LV side of the interconnection transformer to provide protection against SLG faults on the interconnection line at the utility/HV side. The designed distance relay executes an enhanced apparent impedance calculation using residual voltage compensation to correctly detect the fault, properly measure the fault location, and timely isolate the fault. In this paper, various scenarios are analyzed using ASPEN and PSCAD simulation tools to demonstrate the effectiveness of the proposed method for protecting the microgrid interconnection line under different fault scenarios.

22 July 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
DLDongdong Li
Dongdong Li
MSMengxian Sun
Mengxian Sun
YFYong Fu
Yong Fu
As large-scale offshore wind farms are integrated into the power grid, a hybrid multi-infeed HVDC (HMIDC) system including both LCC-HVDC and VSC-HVDC links is facing a critical steady-state voltage stability problem which mainly stems from a weak AC system under high-level DC power injections. To overcome this challenge, this paper proposes a general steady-state voltage stability analysis to accurately measure the critical voltage stability point of HMIDC systems. In this paper, a typical HMIDC system is firstly modeled as a general dual-infeed system composed of an LCC-HVDC, a VSC-HVDC, and a virtual equivalent voltage source behind a virtual equivalent impedance at the AC side. Then a hybrid power sensitive factor (HPSF) is established to indicate the critical voltage stability point with the consideration of dynamic power-voltage characteristics of HVDC links, as well as operational changes in AC system (e.g. dynamics of excitation voltage control in generator and network topology change). Finally, a general voltage stability index, called hybrid generalized short circuit ratio (HGSCR), is further derived to effectively explain the critical voltage stability point of HMIDC systems. Moreover, multiple comparative studies with existing voltage stability indices are conducted in this paper to verify the effectiveness of the proposed general steady-state voltage stability analysis by using both PSCAD/EMTDC™ power flow and time-domain simulations.