K. S. Veliev

K. S. Veliev

Auto-generated profile, based on publicly available information

K. S. Veliev

Rostov State Medical University; Rostov-on-Don Clinical Hospital «RZD-Medicine

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2022 in Pirogov Russian Journal of Surgery
Verified
Journal Article
Closed access
AKA.G. Khitaryan
A.G. Khitaryan
NMN.L. Matveev
N.L. Matveev
KVK.S. Veliev
K.S. Veliev
AGA.A. Golovina
A.A. Golovina
AMA.V. Mezhunts
A.V. Mezhunts
VLV.A. Lyapina
V.A. Lyapina
Until recently, clinical studies in the field of robotic-assisted surgery have been conducted in Russia only on the basis of the DaVinci system. The advent of a new robotic system separated the concept of «robotic surgery» from DaVinci. An increase in the number of alternative surgical robots will expand the possibilities of studying the functionality of these systems, differences in their operation, safety and efficiency for patients, and convenience for surgeons. Evaluation of own initial experience of using Senhance robotic surgical system in the work of the general surgery department. A prospective collection of data on the surgical treatment of patients with various pathologies using the Senhance robotic system was carried out, followed by its analysis in relation to the duration of the operation, the incidence of intraoperative complications and the need for conversion, as well as the volume of blood loss and early postoperative complications. Now, only perioperative, and early postoperative data are available for analysis. While accumulating our own experience with the Senhance system, we concluded that, since the transition from robotic to manual laparoscopic surgery and vice versa does not require changing of access points and is performed quickly, it is practically expedient to perform some stages of the operation manually, and others using surgical robot. For example, with the help of manual laparoscopy, it is more ergonomic to perform wide tractions and movements of organs and tissues. At the same time, robotic surgery has undeniable advantages when performing lymph node dissection, performing manual sutures, including anastomoses, which does not lead to an increase in the duration of the intervention. Presented experience of using the Senhance system has shown that it meets the declared indicators of convenience, efficiency and safety of operations in general surgery.

2 May 2023 in Ambulatornaya khirurgiya = Ambulatory Surgery (Russia)
Verified
Journal Article
Open access
PDF file
AKA. G. Khitaryan
A. G. Khitaryan
ALA. A. Ledenev
A. A. Ledenev
AOA. A. Orekhov
A. A. Orekhov
KVK. S. Veliev
K. S. Veliev
VLV. A. Lyapina
V. A. Lyapina
VBV. N. Bondarenko
V. N. Bondarenko
Chronic venous insufficiency, being the outcome and complication of most diseases of the veins of the lower extremities, is the fundamental cause of the formation of trophic ulcers. Over the past decade, in solving the problem of treating venous trophic ulcers, certain successes have been achieved, both in theoretical and practical terms. The modern concept of curation of patients with trophic ulcers of venous origin involves a reasonable combination of the following methods of treatment: local, including compression, as well as medical, surgical, minimally invasive and additional methods (physiotherapy, photodynamic therapy, etc.). The main goal of the treatment is to eliminate the ulcer, after which measures are taken to correct the underlying cause (chronic venous insufficiency) and prevent relapse. However, the tactics of the most successful treatment of patients with trophic ulcers of venous etiology is still not defined and requires further improvement. In particular, the method of photodynamic therapy, which includes the usage of special drugs - photosensitizers, also deserves to be studied and expanded for clinical use. The mechanism of photodynamic action is based on the ability of photosensitizers to accumulate in microbial and pathological cells. Under local light exposure, the photosensitizer enters an excited state and charges oxygen, which is associated with erythrocyte hemoglobin. Thus, in cells under the influence, a photochemical reaction is triggered, which ensures the formation of singlet oxygen and its free radicals. Reactive oxygen species, in turn, have a damaging effect on pathogenic flora and necrotic tissues. The main advantages of the method are relative simplicity, no risk of developing antibiotic resistance, acceleration of reparative and regenerative processes, and prevention of secondary infection. Thus, photodynamic therapy allows non-invasive, safe and effective optimization of local treatment and preoperative preparation of patients with venous trophic ulcers.

1 December 2023 in Koloproktologia
Verified
Journal Article
Open access
PDF file
AKA. G. Khitaryan
A. G. Khitaryan
AGA. A. Golovina
A. A. Golovina
KVK. S. Veliev
K. S. Veliev
AMA. V. Mezhunts
A. V. Mezhunts
AAA. Z. Alibekov
A. Z. Alibekov
KOK. S. Oplimah
K. S. Oplimah
Aim: to assess primary results of robot-assisted ventral mesh procedure using the new Senhance® robotic system for obstructive defecation syndrome.Patients and Methods: the prospective cohort study included patients who underwent robot-assisted ventral mesh rectopexy with the Senhance® system for obstructive defecation syndrome caused by rectocele and/or rectal prolapse and/or internal intussusception. The optimal trocar sites, the location of robotic arms, operation time and intraoperative blood loss were evaluated, as well as post-op morbidity rate (Clavien-Dindo scale), pain intensity (VAS scale) and recurrence rate.Results: the study included 22 patients. Operation time was 87.1 ± 24.3 minutes. The intraoperative blood loss was 19.8 ± 9.6 ml. No conversion to open or laparoscopic approach occurred, no morbidity occurred. Pain intensity on day 1 was 0.255 mm according to VAS. No anatomical recurrence was revealed. The median follow-up period was 20.4 months (7–22 months).Conclusion: robotic-assisted ventral rectopexy using the Senhance® system is effective and safe. The results are similar to laparoscopic ones. However, the use of the Senhance® system is cost effective compared to other robotic systems.

23 April 2023 in Pirogov Russian Journal of Surgery
Verified
Journal Article
Closed access
AKA.G. Khitaryan
A.G. Khitaryan
AMA.V. Mezhunts
A.V. Mezhunts
KVK.S. Veliev
K.S. Veliev
DMD.A. Melnikov
D.A. Melnikov
AAA.A. Abovyan
A.A. Abovyan
ARA.A. Rogut
A.A. Rogut
Objective. To study the results of robot-assisted bariatric surgery using the Senhance system in patients with morbid obesity. Material and methods. A prospective cohort study included 74 patients who underwent bariatric surgery (Senhance digital laparoscopy system) between January 2022 and May 2023. Of these, 12 patients underwent robot-assisted longitudinal gastrectomy, 20 patients — robot-assisted Roux-en-Y gastric bypass, 36 patients — robot-assisted gastric bypass with one anastomosis/mini-gastric bypass, 6 patients — surgical exploration. We assessed duration of surgery, docking, placement of trocars and robotic manipulators, the need for their intraoperative displacement, incidence of intraoperative complications and conversions to laparoscopic surgery, intraoperative blood loss and early postoperative complications, severity of pain syndrome on the 1st day after surgery. Results. Mean surgery time was 87 [67, 120], 116 [78, 139], 96 [79, 125] and 141 [112, 184] min, respectively. Intraoperative blood loss was less than 50 ml. There were no complications requiring surgical treatment, cardiovascular, respiratory and other complications within 1 month. Conclusion. Robot-assisted bariatric surgery using the Senhance system is feasible and safe for patients. Immediate results of robotic surgery are comparable to those after laparoscopy. However, large experience and cost-effectiveness analysis are required to assess the feasibility of robotic systems in bariatric surgery.

13 January 2025 in Ambulatornaya khirurgiya = Ambulatory Surgery (Russia)
Verified
Journal Article
Open access
PDF file
AKA. G. Khitaryan
A. G. Khitaryan
EKE. Ya. Kirtanasova
E. Ya. Kirtanasova
AOA. A. Orekhov
A. A. Orekhov
DGD. A. Gusarev
D. A. Gusarev
VKV. N. Kislyakov
V. N. Kislyakov
DSD. V. Shatov
D. V. Shatov
Introduction. Endovenous laser ablation combined with sclerotherapy are effective treatment options for varicose veins of the lower limb. However, sclerotherapy is associated with an increased risk of side effects in patients with morbid obesity, which makes it challenging.Aim. To improve efficiency of the varicose veins of the lower limb treatment in patients with morbid obesity by using the aspects of “hemodynamic sclerotherapy”.Materials and methods. Prospective comparative study included 109 patients with C3–C5 classes of chronic venous diseases and morbid obesity was performed. All patients were treated with endovenous laser ablation combined with sclerotherapy. In the main group (n = 56) sclerotherapy was performed in the Trendelenburg position, in the control group (n = 53) – in the horizontal position.Results. The diameter reduction of the great saphenous vein by 22.5% in the Trendelenburg position with 15° incline was statically significant (p < 0.001). The perforating veins reflux in the Trendelenburg position with 15° incline was not detected in 72.3% of patients (p < 0.001). The occlusion rates of the varicose tributaries not treated with sclerosant in the main group was 41% (p = 0.032). In the main group only 12.5% of patients were found to have phlebitis (p = 0.029), the Visual Analog Score (p = 0.036) and local temperature (p = 0.049) were also significantly lower. The incomplete occlusion rate of the varicose tributaries in the main group was only 5.3%; however, the difference was not statically significant.Discussion. The perforating veins reflux in the Trendelenburg position and the incomplete occlusion of the varicose tributaries were only in obese patients with body mass index more than 55 kg/m2 and C4b–C5 classes.Conclusions. Sclerotherapy in the Trendelenburg position with the legs elevated at least 15° incline improves the efficiency of the varicose vein’s occlusion in patients with morbid obesity. Sclerotherapy in obese patients with body mass index more than 55 kg/m2 has less effect.

8 June 2020 in Ambulatornaya khirurgiya = Ambulatory Surgery (Russia)
Verified
Journal Article
Open access
PDF file
AKA. G. Khitaryan
A. G. Khitaryan
AMA. S. Murlychev
A. S. Murlychev
IBI. V. Bondarenko
I. V. Bondarenko
SKS. A. Kovalev
S. A. Kovalev
KVK. S. Veliev
K. S. Veliev
AGA. A. Golovina
A. A. Golovina
Introduction. Acute mesenteric ischemia is a rare, but extremely severe life-threatening condition with a mortality rate of 40 to 60%, despite the development of modern high-tech diagnostic and treatment methods. Unfortunately, acute mesenteric ischemia does not have any pathognomonic symptoms or highly specific laboratory and instrumental symptoms and manifests as abdominal pain syndrome, which makes it harder to differentiate diagnosis and results in a delay in taking appropriate therapeutic measures.Clinical case. This clinical case report describes a case of a 70-year-old patient who was admitted to the cardiology department after undergoing percutaneous coronary intervention due to acute myocardial infarction. On the third day, the patient developed severe diffuse abdominal pain and diarrhea. After the series of diagnostic measures have been performed, an acute impairment of mesenteric circulation was suspected and a decision was made to perform spiral computed tomography, which confirmed the presence of a thrombus in the superior mesenteric artery. The patient underwent X-ray endovascular thrombospiration, transluminal balloon angioplasty and stenting of the superior mesenteric artery. Due to the persistence of abdominal pain on the following day, the patient also underwent a diagnostic laparoscopy using ICG technologies to assess the presence and severity of ischemic and necrotic intestinal changes. After six months from the date of discharge, the patient continues to be followed-up by a cardiologist.Conclusions. The timely performance of spiral computed tomography in patients with suspected acute mesenteric ischemia in the vascular regimen, angiography, endovascular interventions to restore blood supply to the intestine and ICG control of perfusion is appropriate to improve the treatment outcomes of this category of patients.