Lukas Waltenberger

Lukas Waltenberger

Auto-generated profile, based on publicly available information

Lukas Waltenberger

Department of Prosthodontics and Biomaterials, Centre for Implantology, RWTH Aachen University Hospital, Aachen, Germany

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 September 2021 in Clinical Oral Implants Research
Verified
Journal Article
Open access
PDF file
LWLukas Waltenberger
Lukas Waltenberger
SWStephanie Wied
Stephanie Wied
SWStefan Wolfart
Stefan Wolfart
TTTaskin Tuna
Taskin Tuna
Objectives: This in vitro study examined the effect of different implant drilling template designs on heat generation during osteotomy and on cooling fluid distribution.Material and methods: Five different template designs were investigated in a standardized setup against a control group and a negative control group: Occlusal‐splint‐design (OSD), OSD‐covering, OSD‐lateral opening, Bar design, and Orientation template. Pilot and one consecutive drill were run at 800 rpm with external irrigation and 2‐kg load. Thermocouples recorded temperature changes at depths of 3, 6, and 9 mm in a bovine rib model. In the second experimental setup, the drill channel of one rib sample was perforated, and the irrigation volume passing through the drill channel was collected separately over time.Results: Following mean temperature rises occurred [in °C]: control, 4.9; negative control, 12; OSD, 5.6; OSD‐covering, 4.7; OSD‐lateral opening, 3.8; Bar design, 5.1; and Orientation template, 4.9. The highest temperature increases were found at a drilling depth of 6 mm (p < .006). The 2.2‐mm drill resulted in a significantly higher temperature rise than the 2.8‐mm drill (p < .001). The mean volume (ml/min) of irrigation through the drill channel was Control group‐flow, 28.5; OSD, 4.1; OSD‐covering, 2; OSD‐lateral opening; 5.8; bar design, 4; and Orientation template, 24.1.Conclusion: Within the limitations, it was shown that fully guided drilling templates reduce the amount of cooling liquid at the point of osteotomy. The template design had an influence on the effective volume of the cooling liquid. However, this did not seem to increase the intraosseous temperature significantly.

19 August 2024 in Clinical Implant Dentistry and Related Research
Verified
Journal Article
Open access
LWLukas Waltenberger
Lukas Waltenberger
SRSven Reich
Sven Reich
MZMarcel Zwahlen
Marcel Zwahlen
SWStefan Wolfart
Stefan Wolfart
Objective: The SafetyCrown workflow facilitates the immediate restoration of posterior single sites with the one‐abutment/one‐time concept. This randomized clinical trial aimed to assess the direct effect of immediate restoration on dental patient‐reported outcomes (dPROs), feasibility, implant accuracy, and time.Materials and Methods: Participants with a single posterior edentulous site for late implant placement underwent optical impressions, shade selection, and cone beam computed tomography. After virtual treatment planning, they were randomized into the test group and the control group. For the test group, individual definitive hybrid abutments were prefabricated. The next step was a fully guided surgery with printed guides. After the implant was placed using guided surgery, the abutment was inserted. A chairside CAD/CAM workflow was used to provide the patient with a provisional restoration. Implants in the control group were left submerged to heal. Oral health‐related quality of life (OHRQoL) was assessed using the OHIP‐G14, and dPRO was measured using a 10‐item visual analog scale (VAS) questionnaire. Additional measurements of implant accuracy and time were performed. Follow‐up was performed 7 to 10 days after implant placement.Results: Thirty‐nine participants with 45 restorations were included (test group: 23, control: 22). Immediate restoration was successful in 21 out of 23 implants (91.3%) in the test group. Both groups exhibited decreased OHRQoL without significant intergroup differences, while patient satisfaction was high overall. Test group participants perceived higher benefits and satisfaction with immediate loading than participants in the control group. Implant accuracy averaged 0.60 mm at the shoulder and 0.95 mm at the apex. Operative time was longer in the immediate loading group (61.9 min) than in the control group (32.1 min) (p < 0.001).Conclusions: Considering the limitations, the immediate restoration of late placed posterior implants using the described workflow proved feasible in 21 out of 23 cases. Both groups achieved high patient satisfaction with no differences in OHRQoL during the first week. Patients who received immediate loading rated the benefits very highly and were satisfied with the provisional restoration during the healing period.

4 November 2023 in Journal of Dentistry
Verified
Journal Article
Closed access
LWL Waltenberger
L Waltenberger
DRD R Reissmann
D R Reissmann
SBS Blender
S Blender
EFE Fritzer
E Fritzer
GHG Heydecke
G Heydecke
NPN Passia
N Passia

13 August 2025 in International Journal of Implant Dentistry
Verified
Journal Article
Open access
LWLukas Waltenberger
Lukas Waltenberger
SBShaza Bishti
Shaza Bishti
SWStefan Wolfart
Stefan Wolfart
Purpose: With increasing demand for aesthetic, metal-free restorations, all-ceramic materials have gained popularity in implant prosthodontics. However, questions regarding their long-term performance, material selection, and design features remain unresolved. This guideline, developed by the German Association of Oral Implantology (DGI) in collaboration with the German Society of Dentistry and Oral Medicine (DGZMK), aims to enhance treatment safety, guide clinical decision-making, and improve patient education concerning all-ceramic implant-supported restorations. Methods: A systematic literature review was conducted to evaluate the clinical performance of all-ceramic restorations in three main indications: implant-supported single crowns, short-span fixed dental prostheses, and full-arch restorations. Recommendations were developed based on the quality of evidence or expert consensus. Results: For single crowns, lithium disilicate, silicate ceramics, and all generations of zirconia demonstrated favorable 3-year survival rates (~ 96–97%). In contrast, polymer-infiltrated ceramics showed inferior performance and were not recommended. For short-span FDPs and full-arch reconstructions, only 3Y-TZP zirconia is supported by clinical evidence. Micro-veneering and monolithic designs reduce chipping risks. Patient education is emphasized due to limited evidence for newer materials and full-arch restorations. Conclusions: All-ceramic implant restorations can be successfully implemented with careful material selection, adherence to bonding protocols, and appropriate prosthetic design. However, clinical limitations persist, especially in full-arch indications. Interdisciplinary collaboration is essential to optimize outcomes and minimize complications.

6 September 2022 in International Journal of Implant Dentistry
Verified
Journal Article
Open access
PDF file
LWLukas Waltenberger
Lukas Waltenberger
SWStefan Wolfart
Stefan Wolfart
Introduction: The patient-centered SafetyCrown-workflow enables the immediate restoration of posterior missing teeth and short free-end situations following one-abutment/one-time within three visits and only one surgical approach. This prosthodontic rehabilitation aims to combine the advantages of cemented and screw-retained restorations. Report: The concept has been performed with 4 restorations in 3 patients and followed up for up to 1 year (mean: 11.2 months) without technical and/or biological complication. Visit 1: Intraoral optical impression, CBCT, and tooth shade selection. Virtual implant planning is performed, and a surgical guide is printed. After exporting the planned implant position, a tooth-colored abutment is fabricated from zirconia with a 1-mm supragingival cementation line, adhesively bonded to a titanium base. Visit 2: Fully navigated implant placement with insertion of the definitive abutment. Subsequently, optical impressions are prepared for A: immediate restoration using a PMMA crown without functional contacts; B: definitive crown fabricated from monolithic zirconia and individualized. The localization of the screw channel is marked using stain thus permitting precise screw channel access, if necessary. Visit 3: After osseointegration of the implant, the definitive crown is adhesively cemented supragingival. In a retrospective analysis of PROMs (‘How stressful was the treatment process […]?’ (0 = not stressful at all, 100 = very stressful), mean VAS score for SafetyCrown of 14 (SD 11.7) and 29.8 (SD 23.1) for standard procedure were present. Conclusion: The SafetyCrown offers a shortened, patient-oriented concept for implant-supported single-tooth reconstructions omitting second-stage surgery. Clinical performance and hypothesized prosthodontic benefits require confirmation via an RCT.

1 January 2026 in Journal of Prosthodontic Research
Verified
Journal Article
Open access
PDF file
LWLukas Waltenberger
Lukas Waltenberger
SRSven Reich
Sven Reich
TGTobias Graf
Tobias Graf
SWStefan Wolfart
Stefan Wolfart
Purpose: To assess the time efficiency of an innovative workflow (SafetyCrown) for implant-supported rehabilitation of posterior single-tooth sites against the standard workflow. The hypothesis was that there is no difference in treatment duration and accuracy, as represented by the number of clinical adjustments and additional visits required.Methods: 31 participants (16 females, 15 males) were included in this analysis from a randomized clinical trial. Participants were randomly assigned to the test group (SafetyCrown workflow, three visits) or control group (conventional digital workflow, six visits). The SafetyCrown workflow combined immediate restoration with a prefabricated definitive abutment and chairside provisional restoration. The control group followed a conventional digital approach in six visits. Treatment times per visit were recorded with a stopwatch; clinical adjustments and additional visits were documented.Results: The SafetyCrown workflow was completed in three visits in 53% of cases, with a mean of 3.5 visits compared with 6.1 visits in the control group. The total treatment time differed insignificantly by 10 minutes (test: 126.4 minutes; 95% CI: 116.4–136.5; control: 116.8 minutes; 95% CI: 104.4–129.3; P = 0.232), and individual visits lasted longer in the test group (e.g., surgical visit: 62 minutes vs. 33 minutes in control). Clinical adjustments were common in both groups when using model-free workflows.Conclusions: Limitations aside, the SafetyCrown workflow reduced the total visits while maintaining the overall treatment time despite longer individual appointments, thus increasing efficiency. Both fully digital workflows were feasible, although frequent adjustments highlight the need to investigate sources of inaccuracy to improve the precision and efficiency further.