Eric Gregoire

Eric Gregoire

Auto-generated profile, based on publicly available information

Eric Gregoire

Institut de Radioprotection et de Sûreté Nucléaire, Fontenay-aux-Roses, France

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 October 2016 in International Journal of Radiation Biology
Verified
Journal Article
Open access
UOUrsula Oestreicher
Ursula Oestreicher
DSDaniel Samaga
Daniel Samaga
EAElizabeth Ainsbury
Elizabeth Ainsbury
AAAna Catarina Antunes
Ana Catarina Antunes
ABAns Baeyens
Ans Baeyens
AWAndrzej Wojcik
Andrzej Wojcik
Purpose: Two quality controlled inter-laboratory exercises were organized within the EU project ‘Realizing the European Network of Biodosimetry (RENEB)’ to further optimize the dicentric chromosome assay (DCA) and to identify needs for training and harmonization activities within the RENEB network. Materials and methods: The general study design included blood shipment, sample processing, analysis of chromosome aberrations and radiation dose assessment. After manual scoring of dicentric chromosomes in different cell numbers dose estimations and corresponding 95% confidence intervals were submitted by the participants. Results: The shipment of blood samples to the partners in the European Community (EU) were performed successfully. Outside the EU unacceptable delays occurred. The results of the dose estimation demonstrate a very successful classification of the blood samples in medically relevant groups. In comparison to the 1st exercise the 2nd intercomparison showed an improvement in the accuracy of dose estimations especially for the high dose point. Conclusions: In case of a large-scale radiological incident, the pooling of ressources by networks can enhance the rapid classification of individuals in medically relevant treatment groups based on the DCA. The performance of the RENEB network as a whole has clearly benefited from harmonization processes and specific training activities for the network partners.

1 August 2013 in Mutation Research - Genetic Toxicology and Environmental Mutagenesis
Verified
Journal Article
Closed access
HRH. Romm
H. Romm
EAE. Ainsbury
E. Ainsbury
SBS. Barnard
S. Barnard
LBLleonard Barrios
Lleonard Barrios
JBJoan-Francesc Barquinero
Joan-Francesc Barquinero
AWA. Wojcik
A. Wojcik

23 August 2012 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
PDF file
UKU. Kulka
U. Kulka
LAL. Ainsbury
L. Ainsbury
MAMichael Atkinson
Michael Atkinson
JBJoan-Francesc Barquinero
Joan-Francesc Barquinero
LBLleonard Barrios
Lleonard Barrios
AWA. Wojcik
A. Wojcik
In Europe, a network for biological dosimetry has been created to strengthen the emergency preparedness and response capabilities in case of a large-scale nuclear accident or radiological emergency. Through the RENEB (Realising the European Network of Biodosimetry) project, 23 experienced laboratories from 16 European countries will establish a sustainable network for rapid, comprehensive and standardised biodosimetry provision that would be urgently required in an emergency situation on European ground. The foundation of the network is formed by five main pillars: (1) the ad hoc operational basis, (2) a basis of future developments, (3) an effective quality-management system, (4) arrangements to guarantee long-term sustainability and (5) awareness of the existence of RENEB. RENEB will thus provide a mechanism for quick, efficient and reliable support within the European radiation emergency management. The scientific basis of RENEB will concurrently contribute to increased safety in the field of radiation protection.

6 October 2016 in International Journal of Radiation Biology
Verified
Journal Article
Open access
UKUlrike Kulka
Ulrike Kulka
MAMichael Abend
Michael Abend
EAElizabeth Ainsbury
Elizabeth Ainsbury
Christophe BadieChristophe Badie
Christophe Badie
JBJoan-Francesc Barquinero
Joan-Francesc Barquinero
AWAndrzej Wojcik
Andrzej Wojcik
Purpose: A European network was initiated in 2012 by 23 partners from 16 European countries with the aim to significantly increase individualized dose reconstruction in case of large-scale radiological emergency scenarios. Results: The network was built on three complementary pillars: (1) an operational basis with seven biological and physical dosimetric assays in ready-to-use mode, (2) a basis for education, training and quality assurance, and (3) a basis for further network development regarding new techniques and members. Techniques for individual dose estimation based on biological samples and/or inert personalized devices as mobile phones or smart phones were optimized to support rapid categorization of many potential victims according to the received dose to the blood or personal devices. Communication and cross-border collaboration were also standardized. To assure long-term sustainability of the network, cooperation with national and international emergency preparedness organizations was initiated and links to radiation protection and research platforms have been developed. A legal framework, based on a Memorandum of Understanding, was established and signed by 27 organizations by the end of 2015. Conclusions: RENEB is a European Network of biological and physical-retrospective dosimetry, with the capacity and capability to perform large-scale rapid individualized dose estimation. Specialized to handle large numbers of samples, RENEB is able to contribute to radiological emergency preparedness and wider large-scale research projects.

20 July 2016 in International Journal of Radiation Biology
Verified
Journal Article
Open access
EAElizabeth Ainsbury
Elizabeth Ainsbury
Christophe BadieChristophe Badie
Christophe Badie
SBStephen Barnard
Stephen Barnard
GMGrainne Manning
Grainne Manning
JMJayne Moquet
Jayne Moquet
CWClemens Woda
Clemens Woda
Purpose: RENEB, ‘Realising the European Network of Biodosimetry and Physical Retrospective Dosimetry,’ is a network for research and emergency response mutual assistance in biodosimetry within the EU. Within this extremely active network, a number of new dosimetry methods have recently been proposed or developed. There is a requirement to test and/or validate these candidate techniques and inter-comparison exercises are a well-established method for such validation. Materials and methods: The authors present details of inter-comparisons of four such new methods: dicentric chromosome analysis including telomere and centromere staining; the gene expression assay carried out in whole blood; Raman spectroscopy on blood lymphocytes, and detection of radiation-induced thermoluminescent signals in glass screens taken from mobile phones. Results: In general the results show good agreement between the laboratories and methods within the expected levels of uncertainty, and thus demonstrate that there is a lot of potential for each of the candidate techniques. Conclusions: Further work is required before the new methods can be included within the suite of reliable dosimetry methods for use by RENEB partners and others in routine and emergency response scenarios.

1 May 2013 in Radiation Research
Verified
Journal Article
Closed access
GGGaetan Gruel
Gaetan Gruel
EGEric Grégoire
Eric Grégoire
SLSarah Lecas
Sarah Lecas
CMCécile Martin
Cécile Martin
SRSandrine Roch-Lefevre
Sandrine Roch-Lefevre
JBJoan-Francesc Barquinero
Joan-Francesc Barquinero
Dicentric chromosome analysis remains the most widely used method in biodosimetry. It has a lower detection limit of about 0.1 Gy, and allows one to distinguish between whole- and partial-body exposures. A drawback of the dicentric analysis is that it is a time consuming method and maybe difficult to implement in a mass casualty event. To try to increase the analysis capacity, automatic dicentric scoring (ADS) using image analysis software is being incorporated in several laboratories. Here we present the results obtained in an emergency exercise simulating 50 victims. The ability to distinguish different radiations scenarios is evaluated. To simulate whole-body exposures peripheral blood samples were irradiated at doses between 0-4.7 Gy, and to simulate partial-body exposures irradiated and nonirradiated blood were mixed in different proportions. With the data obtained from the first slide analyzed (with about 300-400 cells), 32 of 34 simulated whole-body exposures were correctly classified according to radiation exposure levels. For simulated partial-body irradiations, it was possible to detect them as partial exposures at the end of the first slide analyzed but only at the highest doses. In all cases the classification was updated every time the analysis of one additional slide was finished. The comparison between our present results and those reported in the literature for manual scoring shows that for triage purposes the ADS based on 300-400 cells is similar in efficiency to classifying the cases based on manual scoring of 50 cells. However, if one accounts for the associated uncertainties and the time needed for ADS, we suggest that ADS triage scoring should be based on about 1,000 cells. For final dose estimations the number of cells to score will depend on the initial estimated dose, and on the information contributed from physical dose-reconstruction or clinical symptoms. At doses higher than 1 Gy, we propose analysis of 1,500 and for lower doses or suspected partial-body exposures, the number of cells to score should be 3,000.