1 April 1988 in Journal of Clinical Gastroenterology
The effect on gastric emptying of 400 mg cimetidine and two doses of ranitidine (150 and 300 mg) given orally was evaluated in 45 patients with endoscopically proved duodenal ulcer and in 28 healthy controls. Gastric emptying of a radiolabeled solid phase meal was assessed. Cimetidine was confirmed not to have any significant influence on gastric emptying in duodenal ulcer patients or in health subjects. The significant delay in gastric emptying observed with ranitidine was dose dependent, and at the same time more pronounced in patients with duodenal ulcer than in healthy subjects. Early ulcer healing was unrelated to the changes in gastric emptying elicited by the tested drugs.
19 February 2013 in Journal of Gastroenterology
Current knowledge about the effect of alcoholic beverages on postprandial functioning of the digestive system is scarce and inconsistent. This study addresses their influence upon meal movement along the gut and meal-induced gallbladder emptying.
1 January 2005 in Journal of Smooth Muscle Research
In a study aimed to test the effect of body position on the parameters derived from surface electrogastrograms, 17 healthy volunteers (2M, 15F; median age 22.5 years) attended in random order two examination sessions held on separate days. A 30-min recording of the interdigestive gastric myoelectrical activity (GMA) was followed by a 90-min postprandial recording after intake of a 394 kcal mixed solid-liquid test meal. For the first examination the subject was examined in a recumbent position, whereas for the second examination a sitting position was maintained. The dominant frequency and relative time occupied by normogastria was negligibly affected by the posture of the subject during GMA recording. However, a decrease in the dominant power (DP) of the gastric slow waves was observed during both the interdigestive and the postprandial recording period in a sitting position compared to a recumbent position. Consequently, the fed to fasted state DP ratio remained unaffected by body posture during GMA recording. The results indicate that by carefully observing procedural guidelines, good quality electrogastrograms can be obtained with a sitting subject, enabling the provision of comparable parameters to those achieved from standard examination in a recumbent position.
31 January 2011 in Isotopes in Environmental and Health Studies
It is essential to establish whether and how environmental factors affect the reliability of [13C]methacetin breath test (13C-MBT). In 12 healthy volunteers (smokers), a standard 13C-MBT with 75 mg [13C]methacetin was performed twice in random order: on a control day without smoking and on another day with smoking two cigarettes antecedently. A considerable flattening of the curve of the momentary 13C recovery within the expiratory air was observed when the 13C-MBT was performed after smoking. The maximum of the momentary 13C recovery, D max, decreased from 37.20±2.58 to 25.39±2.29% dose/h (p=0.00052). Moreover, the time to reach D max was prolonged after cigarette smoking (26.5±3.1 vs. 16.5±1.9 min, p=0.0199). The curve of the cumulative 13C recovery on the cigarette smoking day appeared to be shifted downwards, and statistically significant differences relative to the control situation were found between the 24th and 75th minute following [13C]methacetin administration. Smoking cigarettes immediately prior to the 13C-MBT diminishes the ability of the liver to handle methacetin, and hence a possibility of such an interaction should be excluded in order to interpret the results of the test correctly.
1 July 2005 in Journal of Gastroenterology and Hepatology
DSDanuta Syrkiewicz‐Trepiak
Danuta Syrkiewicz‐Trepiak
1 January 2006 in Journal of Smooth Muscle Research
BKBeata Krusiec-Swidergol
BBBarbara Blonska-Fajfrowska
Barbara Blonska-Fajfrowska
The goal of the study was to establish if the conductive area size of recording electrodes affects the quality of a multichannel electrogastrogram. In twelve volunteers (9F, 3M, median age 24 years, range 22-28) on three separate days fasted and postprandial four-channel electrogastrograms were registered in randomized order with Red Dot class Ag/AgCl electrodes of a type: `2222' (conductive area/total area: 2.00/10.24 cm2, `2271' 2.54/29.64 cm2, or `2660' 11.64/11.64 cm2 (total surface conductive!), and subsequently analyzed with a dedicated software. In the case of type 2271 and 2660 the between-electrode electrical conductivity improved at the end of the recording relative to the basal measurement, whereas type 2222 yielded a stable between-electrode electrical conductivity throughout the examination. Despite the differences in either the conductive area size or its construction, the analysis of variance on parameters describing quantitatively the multichannel electrogastrogram did not reveal a superiority of any from among the electrodes tested. Type 2271 was, however, rated the less handy among the three electrodes. Multichannel surface electrogastrography seems to be technically feasible with any type of high quality electrodes, therefore small dimensions and easy handling may favor the choice of a particular type for this examination.