Lucas Griffith

Lucas Griffith

Auto-generated profile, based on publicly available information

Lucas Griffith

Ames National Laboratory U.S. Department of Energy Iowa State University Ames IA 50011 USA

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 January 2018 in Journal of Applied Physics
Verified
Journal Article
Closed access
LGL. D. Griffith
L. D. Griffith
Yaroslav MudrykYaroslav Mudryk
Yaroslav Mudryk
JSJ. Slaughter
J. Slaughter
VPV. K. Pecharsky
V. K. Pecharsky
The efficient use of reversible thermal effects in magnetocaloric, electrocaloric, and elastocaloric materials is a promising avenue that can lead to a substantially increased efficiency of refrigeration and heat pumping devices, most importantly, those used in household and commercial cooling applications near ambient temperature. A proliferation in caloric material research has resulted in a wide array of materials where only the isothermal change in entropy in response to a handful of different field strengths over a limited range of temperatures has been evaluated and reported. Given the abundance of such data, there is a clear need for a simple and reliable figure of merit enabling fast screening and down-selection to justify further detailed characterization of those material systems that hold the greatest promise. Based on the analysis of several well-known materials that exhibit vastly different magnetocaloric effects, the Temperature averaged Entropy Change is introduced as a suitable early indicator of the material's utility for magnetocaloric cooling applications, and its adoption by the caloric community is recommended.

1 May 2012 in Journal of Power Sources
Verified
Journal Article
Closed access
ASAaron A. Shinkle
Aaron A. Shinkle
ASAlice E.S. Sleightholme
Alice E.S. Sleightholme
LGLucas D. Griffith
Lucas D. Griffith
LTLevi T. Thompson
Levi T. Thompson
CMCharles Monroe
Charles Monroe

16 March 2015 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
LGLucas D. Griffith
Lucas D. Griffith
ASAlice E.S. Sleightholme
Alice E.S. Sleightholme
JMJohn F. Mansfield
John F. Mansfield
DSDonald J. Siegel
Donald J. Siegel
CMCharles Monroe
Charles Monroe

19 May 2020 in Journal of Applied Physics
Verified
Journal Article
Open access
PDF file
JSJulie Slaughter
Julie Slaughter
ACAgata Czernuszewicz
Agata Czernuszewicz
LGLucas Griffith
Lucas Griffith
VPVitalij Pecharsky
Vitalij Pecharsky
Elastocaloric cooling holds promise for energy-efficient heat pumping near room temperature with low environmental impact. Its adoption is, however, impeded by disproportionally large sizes of actuators compared with the active material volume. Taking magnetocaloric cooling as the baseline, the value of no more than 10:1 actuator volume to active material volume should lead to both size- and cost-effective solutions that may potentially be competitive with vapor-compression devices. With the goal to establish performance metrics that can lead to informed actuator selection for specific regenerator requirements, we analyze a wide range of elastocaloric materials and actuator technologies to find the best matches. We find that actuation with magnetic shape memory alloys meets all requirements; however, this technology is currently in early developmental stages and such actuators are not widely commercially available. Another promising and easily accessible option is standard rotary electric motors in combination with rotary-to-linear transduction mechanisms. A theoretical analysis of two case studies of elastocaloric systems using rotary electric motors with a Scotch yoke mechanism demonstrates the usefulness of our approach. Actuator requirements are based on two different regenerator configurations: one starting from zero strain without any mechanical energy recovery and another with 2% pre-strain and mechanical energy recovery to reduce the power and torque required from the motor. Our results indicate that the 10:1 target actuator to active material volume ratio can be met and feasibly lowered further, demonstrating that the proposed method for selecting actuators makes compact and efficient elastocaloric systems possible.

1 June 2020 in Applied Materials Today
Verified
Journal Article
Closed access
ACAgata Czernuszewicz
Agata Czernuszewicz
LGLucas Griffith
Lucas Griffith
JSJulie Slaughter
Julie Slaughter
VPVitalij Pecharsky
Vitalij Pecharsky

1 November 2019 in Energy Conversion and Management
Verified
Journal Article
Closed access
LGLucas Griffith
Lucas Griffith
ACAgata Czernuszewicz
Agata Czernuszewicz
JSJulie Slaughter
Julie Slaughter
VPVitalij Pecharsky
Vitalij Pecharsky