4 March 2012 in Acta Oto-Laryngologica
Conclusion: A robot built specifically for stereotactic cochlear implantation provides equal or better accuracy levels together with a better integration into a clinical environment, when compared with existing approaches based on industrial robots. Objectives: To evaluate the technical accuracy of a robotic system developed specifically for lateral skull base surgery in an experimental set-up reflecting the intended clinical application. The invasiveness of cochlear electrode implantation procedures may be reduced by replacing the traditional mastoidectomy with a small tunnel slightly larger in diameter than the electrode itself. Methods: The end-to-end accuracy of the robot system and associated image-guided procedure was evaluated on 15 temporal bones of whole head cadaver specimens. The main components of the procedure were as follows: reference screw placement, cone beam CT scan, computer-aided planning, pair-point matching of the surgical plan, robotic drilling of the direct access tunnel, and postoperative cone beam CT scan for accuracy assessment. Results: The mean accuracy at the target point (round window) was 0.56 ± 0.41 mm with an angular misalignment of 0.88 ± 0.40°. The procedural time for the registration process through the completion of the drilling procedure was 25 ± 11 min. The robot was fully operational in a clinical environment.
1 October 2012 in Oral Oncology
1 January 2010 in Otology & Neurotology
With the placement of a floating mass transducer (FMT) at the round window, a new approach of coupling an implantable hearing system to the cochlea has been introduced. The aim of the present experimental study is to examine the influence of different ways of FMT placement at the round window on the vibration energy transfer to the cochlea. Experiments were performed on 8 ears of human whole head specimens. A mastoidectomy and facial recess approach were performed to access the middle ear structures. Seven different conditions were compared, that is, a perpendicular or 90-degree rotated position of the FMT in the round window niche, overlaid or underlaid with connective tissue or with tight fixation and disrupted ossicular chain. The FMT was stimulated electrically and the movements at the FMT, the stapes head, and the promontory were measured using laser Doppler vibrometry. Vibration transmission to the cochlear fluids was best with the FMT placed perpendicular to the round window membrane and underlaid with connective tissue. The energy transfer to the inner ear was up to 45 dB higher compared with tight fixation condition, where the poorest energy transfer was found. Underlaying the FMT with connective tissue improved energy transfer even for a suboptimal orientation of the FMT. The way of coupling of the FMT to the round window has a substantial influence on the vibration transmission. Energy transfer to the inner ear is highest with the FMT placed in the round window and underlaid with tissue.
14 July 2011 in American Journal of Neuroradiology
BACKGROUND AND PURPOSE: The temporal bone is ideal for low-dose CT because of its intrinsic high contrast. The aim of this study was to retrospectively evaluate image quality and radiation doses of a new low-dose versus a standard high-dose pediatric temporal bone CT protocol and to review dosimetric data from the literature. MATERIALS AND METHODS: Image quality and radiation doses were compared for 38 low-dose (80 kV/90–110 mAs) and 16 high-dose (140 kV/170 mAs) temporal bone CT scans of infants to 5-year-old children. The CT visualization quality of 23 middle and inner ear structures was subjectively graded by 3 neuroradiologists and 3 otologists by using a 5-point scale with scores 1–2 indicating insufficient and scores 3–5 indicating sufficient image quality. Effective doses of local and literature-derived protocols were calculated from dosimetric data by using NRPB-SR250 software. RESULTS: Insufficient image-quality scores were more frequent in low-dose scans versus high-dose scans, but the difference was only statistically significant for otologists (6.0% versus 3.4%, P = .004) and not for neuroradiologists (1.2% versus 0.7%, P = .84). Image quality was critical for small structures (such as the stapes or lamella at the internal auditory canal fundus). Effective doses were 0.25–0.3 mSv for low-dose scans, 1.4–1.8 mSv for high-dose scans, and 0.9–2.6 mSv for literature-derived protocols. CONCLUSIONS: The image quality of the new low-dose protocol remains diagnostic for assessing middle and inner ear anatomy despite a 3- to 8-fold dose reduction over previous and literature-derived protocols. However, image quality of small structures is critical and may be perceived as insufficient.
1 May 2010 in Hearing Research
22 October 2012 in Radiation Oncology
Background: To determine the outcome and patterns of failure in oral cavity cancer (OCC) patients after postoperative intensity modulated radiotherapy (IMRT) with concomitant systemic therapy. Methods: All patients with locally advanced (AJCC stage III/IV) or high-risk OCC (AJCC stage II) who underwent postoperative IMRT at our institution between December 2006 and July 2010 were retrospectively analyzed. The primary endpoint was locoregional recurrence-free survival (LRRFS). Secondary endpoints included distant metastasis-free survival (DMFS), overall survival (OS), acute and late toxicities. Results: Overall 53 patients were analyzed. Twenty-three patients (43%) underwent concomitant chemotherapy with cisplatin, two patients with carboplatin (4%) and four patients were treated with the monoclonal antibody cetuximab (8%). At a median follow-up of 2.3 (range, 1.1–4.6) years the 3-year LRRFS, DMFS and OS estimates were 79%, 90%, and 73% respectively. Twelve patients experienced a locoregional recurrence. Eight patients, 5 of which had both a flap reconstruction and extracapsular extension (ECE), showed an unusual multifocal pattern of recurrence. Ten locoregional recurrences occurred marginally or outside of the high-risk target volumes. Acute toxicity grades of 2 (27%) and 3 (66%) and late toxicity grades of 2 (34%) and 3 (11%) were observed. Conclusion: LRRFS after postoperative IMRT is satisfying and toxicity is acceptable. The majority of locoregional recurrences occurred marginally or outside of the high-risk target volumes. Improvement of high-risk target volume definition especially in patients with flap reconstruction and ECE might transfer into better locoregional control.