Milad Ghalamboran

Milad Ghalamboran

Auto-generated profile, based on publicly available information

Milad Ghalamboran

Fibra Inc

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 July 2023 in Advanced Materials Technologies
Verified
Journal Article
Open access
MNMohammad Nazeri
Mohammad Nazeri
MGMilad Ghalamboran
Milad Ghalamboran
GGGerd Grau
Gerd Grau
Organic electrochemical transistors (OECTs) have drawn significant interest because of their low cost, biocompatibility, and ease of fabrication, allowing them to be utilized in various applications including flexible displays, electrochemical sensing, and biosensing. Key components of OECTs are the gate, source, and drain electrodes. Herein, OECTs with laser‐induced graphene (LIG) electrodes are demonstrated. The electrode patterns for the source, drain, and gate are created by converting the polymer substrate polyimide (PI) into LIG using a scanned laser. The process is simple and inexpensive without complicated chemical synthesis routines or expensive materials such as gold. Patterns can be customized quickly and digitally. The low‐cost and porous LIG electrodes with low contact resistance and good electrical stability play an essential role in device performance. The minimum sheet resistance achieved with this laser method for the square patterned electrodes is 7.86 Ω sq−1. The LIG‐based OECTs demonstrate good electrical modulation with ON–OFF ratio of 72.80 and high ON current on the order of mA. The LIG‐based OECTs exhibit comparable or better performance in comparison with other reports of OECTs on plastic substrates using more complex fabrication methods in terms of OFF current, ON current, transconductance (gm), and contact resistance.

3 August 2023 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
ADAlireza Dabbaghian
Alireza Dabbaghian
YEYoland El-hajj
Yoland El-hajj
MGMilad Ghalamboran
Milad Ghalamboran
GGGerd Grau
Gerd Grau
HKHossein Kassiri
Hossein Kassiri
We present the design, development, and experimental characterization of an active electrode (AE) IC for wearable ambulatory EEG recording. The proposed architecture features in-AE double common-mode (CM) rejection, making the recording's CMRR independent of typically-significant AE-to-AE gain variations. Thanks to being DC coupled and needless of chopper stabilization for flicker noise suppression, the architecture yields a super-T $\Omega$ input impedance. Such a large input impedance makes the AE's CMRR practically immune to electrode-skin interface impedance variations across different recording channels, a critical feature for dry-electrode ambulatory systems. Signal quantization and serialization are also performed in-AE, which enables a distributed system in which all AEs use a single data bus for data/command communication to the backend module, thus significantly improving the system's scalability. Additionally, the presented AE hosts auxiliary modules for (i) detection of an unstable electrode-skin connection through continuous interface impedance monitoring, (ii) dynamic measurement and adjustment of input DC level, and (iii) a CM feedback loop for further CMRR enhancement. The article also presents the development of printed (extrusion) tattoo electrodes and their experimental characterization results with the proposed AE architecture. Besides bio-compatibility, low-cost, pattern flexibility, and quick fabrication process, the printed electrodes offer a very stable electrode-skin connection, conform to scalp shape, and exhibit consistent performance under various bending curvatures. Analog circuit blocks of the presented AE architecture are designed and fabricated using a standard 180 nm CMOS technology, and the $1\times \text{1.3}\,\text{mm}^{2}$ IC is integrated with off-chip low-power digital modules on a PCB to form the AE. Our measurement results show a CMRR of 82.2 dB (at 60 Hz), amplification voltage gain of 52.8 dB, a bandwidth of 0.2–400 Hz, $\pm$ 500 mV input DC offset tolerance, An input impedance $> \text{1}\,T\Omega$ , and 0.67 $\mu$ V $_{RMS}$ integrated input referred noise (0.5–100 Hz), while consuming 17.5 $\mu$ W per channel. All auxiliary modules are tested experimentally, and the entire system is validated in-vivo, for both ECG and EEG recording.

1 March 2024 in Flexible and Printed Electronics
Verified
Journal Article
Open access
MGMilad Ghalamboran
Milad Ghalamboran
MNMohammad Nazeri
Mohammad Nazeri
GGGerd Grau
Gerd Grau
When fabricating inkjet-printed electronic devices and circuits, inkjet-printed conductive materials require drying and sintering to improve electrical conductivity. Electrical conductivity should be the same irrespective of pattern design, size, location, or density of adjacent patterns. However, we demonstrate that spatial variations in the drying process for inkjet-printed patterns with proximity to others cause resistivity variations. These resistivity variations are studied here experimentally for different circuit patterns and in arrays of inkjet-printed square electrodes. This variation depends not only on the location of each electrode in an array but also on the number of electrodes. This means that for the same drying temperature and duration, the array with a larger number of electrodes exhibits a larger resistivity variation. The sooner an electrode dries, the lower resistivity it achieves. The resistivity variation between an individual electrode and the center electrode in a 7 × 7 electrode array can be a factor of seven. This variation decreases for lower numbers of electrodes to a factor of three for a 3 × 3 array. Furthermore, x-ray photoelectron spectroscopy analyses provide evidence for the residual presence of carbon-based materials within electrodes after the drying process. These results confirm that the location of electrodes within an array significantly influences the amount of residual carbon-based materials, thereby contributing to resistivity variations. Although intense pulsed light sintering can decrease this variation, its optimal parameters depend on the printed designs, and our simulation results show a non-uniform temperature profile over the electrode arrays. Temperature increases more at the center of patterns than the corners, which can be useful in this case to improve resistivity uniformity. In this study, for the first time, we show how different printed shapes and designs can result in non-uniform resistivity after drying and sintering.

20 July 2026 in Flexible and Printed Electronics
Verified
Journal Article
Open access
PDF file
MGMilad Ghalamboran
Milad Ghalamboran
CJCamille Anne Javonillo
Camille Anne Javonillo
GYGuanhan Yao
Guanhan Yao
GGGerd Grau
Gerd Grau
PMParnian Majd
Parnian Majd
Wearable temperature sensors have emerged as a critical tool in modern healthcare, offering continuous, non-invasive monitoring of physiological parameters. This review presents a comprehensive analysis of fabric- and thread-based skin temperature sensors, focusing on their design principles, materials, fabrication, and biomedical applications. Skin-contact temperature monitoring is essential for detecting fever, managing chronic diseases, aiding post-operative care, and supporting high-risk populations such as neonates and the elderly. In contrast, wearable sensors, particularly those based on textiles, offer superior flexibility, comfort, and integration into daily life. The review categorizes wearable temperature sensors by three primary mechanisms: resistive temperature detectors, thermocouples, and thermistors. Each sensor type is evaluated based on sensitivity, response time, thermal conductivity, and power consumption. Thermoelectric materials, especially conductive polymers such as 3,4-polyethylenedioxythiophene-polystyrene sulfonic acid and polyaniline, and nanomaterials like silver nanowires and carbon nanotubes, are highlighted for their mechanical flexibility, tunable conductivity, and suitability for textile integration. The review also discusses composite materials that synergize the electrical conductivity of inorganic fillers with the stretchability and softness of polymers. Advanced fabrication methods, including spray coating, inkjet and extrusion printing, knitting, weaving, embroidery, and additive manufacturing, enable the integration of temperature sensors into yarns and fabrics without compromising performance or wearability. Techniques such as microencapsulation and yarn encapsulation are discussed for enhancing sensor durability against environmental factors like moisture and washing cycles. The paper further explores real-world biomedical applications, including patient monitoring, wound healing, and thermoregulation in neonatal and geriatric care. Emerging implantable and resorbable textile sensors are also discussed. Finally, key challenges, such as material stability, power management, biocompatibility, and regulatory hurdles, are addressed, outlining the pathway for future development of reliable and wearable thermal monitoring systems. This review aims to guide researchers and developers in advancing textile-integrated temperature sensors for next-generation healthcare solutions.