Mohammad M. Hashempour

Mohammad M. Hashempour

Auto-generated profile, based on publicly available information

Mohammad M. Hashempour

Department of Electrical Engineering, National Sun Yat-Sen University, Kaohsiung, Taiwan

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 October 2015 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
MHMohammad M. Hashempour
Mohammad M. Hashempour
Mehdi SavaghebiMehdi Savaghebi
Mehdi Savaghebi
Juan C. VasquezJuan C. Vasquez
Juan C. Vasquez
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
This paper proposes a control architecture of distributed generators (DGs) inverters and shunt active power filters (APFs) in microgrids to compensate voltage harmonics in a coordinated way. For this, a hierarchical control structure is proposed that includes two control levels. The primary (local) control consists of power controllers, selective virtual impedance loops, and proportional resonant voltage/current controllers. The secondary (central) control manages the compensation level of voltage harmonic distortion of sensitive load bus (SLB). Compensation of SLB harmonics by control of DGs may cause excessive voltage harmonics at the terminal of one or more of DGs interface inverters and/or overloading of the inverters. After occurrence of each case, APF participates in harmonic compensation and consequently the compensation efforts of DGs decrease to avoid excessive harmonics or overloading of interface inverters. Effectiveness of the proposed control scheme is demonstrated through simulation studies.

20 June 2018 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
MHMohammad M. Hashempour
Mohammad M. Hashempour
MYMeng-Ying Yang
Meng-Ying Yang
TLTzung-Lin Lee
Tzung-Lin Lee
An adaptive control of DPWM implementable in clamped-three-level inverters with two strings of PV panels in cascaded connection is proposed in this paper. The proposed modulation is developed based on the so-called circuit-level decoupling concept. It is able to provide balance line voltage even under unbalanced dc links. The unequal dc voltages appeared due to asymmetric MPPTs are controlled by proper injection of zero-sequence voltage to the common mode voltage while the total dc voltage is regulated based on the voltage commands generated by the MPPT of each string. Thus, both PV strings are able to be operated based on their MPPTs while there is almost no low-order harmonic distortion at the inverter output current. Compared with the previous methods, the high capability of the proposed method is evaluated by simulation study and experimental tests.

18 April 2018 in IEEE Systems Journal
Verified
Journal Article
Closed access
MHMohammad M. Hashempour
Mohammad M. Hashempour
TLTzung-Lin Lee
Tzung-Lin Lee
Mehdi SavaghebiMehdi Savaghebi
Mehdi Savaghebi
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
In this paper, the power quality (PQ) improvement of multi-area microgrids (MAMGs) is addressed. To this aim, mitigation of voltage harmonics and unbalance is considered by using distributed generators (DGs) and active power filters (APFs) in a proper way. As a novel approach, the main goal of the proposed method is to pick out redundant APFs and/or significantly reduce of DGs and APFs compensation workload by making collaboration between areas toward integrated PQ improvement of the MAMG. To achieve the desired PQ indices of different areas, supervisory control is planned for proper utilization of available compensators in time. By supervisory control, harmonic propagation between areas and the system unbalance are dealt with and systemic PQ improvement of the MAMG is provided. To this aim, scheduling framework is used to track the PQ situation of each area. Evaluation of the proposed control is carried out by a comprehensive simulation study in MATLAB/Simulink.

1 September 2016
Verified
Conference Paper
Open access
MHMohammad M. Hashempour
Mohammad M. Hashempour
Mehdi SavaghebiMehdi Savaghebi
Mehdi Savaghebi
Juan C. VasquezJuan C. Vasquez
Juan C. Vasquez
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
In this paper, the power quality of microgrids is addressed. To achieve the desired level of power quality, a strategy based on the coordinated control between DGs and APFs is proposed. In this regard, hierarchical control is applied where primary control consists of power droop controller of DGs, selective virtual impedance and voltage/current regulators. Based on the secondary control, at first voltage harmonic compensation and voltage unbalance compensation of point of common coupling (PCC), that might includes sensitive loads, is carried out by DGs. Voltage compensation of PCC by DGs may cause severe voltage distortion at DGs terminals. Thus, the coordinated control is used to mitigate the voltage distortion to the defined maximum allowable value at DGs terminals. Evaluation of the proposed hierarchical control is carried out by a simulation study.

1 June 2017
Verified
Conference Paper
Closed access
MHMohammad M. Hashempour
Mohammad M. Hashempour
TLTzung-Lin Lee
Tzung-Lin Lee
Power factor displacement and voltage fluctuation might produce due to high reactive power consumption of loads or long distribution lines. These power quality problems need more consideration in islanded microgrids (MGs) due to operating in low voltage grid with the absence of main grid. In this line, a novel control strategy for static synchronous compensator (STATCOM) is proposed in this paper to integrally correct power factor and mitigate voltage fluctuation in permissible ranges. In the previous approaches, auxiliary devices are used to compensate a certain point while, depending on load condition and distribution lines lengths, power quality of the other points except of the considered point might need compensation rather. In a different approach, the proposed strategy considers all the DGs buses for power factor correction and all the points of common coupling (PCCs) for voltage regulation. To this aim, communication network is applied. The proposed method is evaluated by MATLAB/Simulink.

1 October 2014
Verified
Conference Paper
Closed access
Mehdi SavaghebiMehdi Savaghebi
Mehdi Savaghebi
MHMohammad M. Hashempour
Mohammad M. Hashempour
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
This paper addresses the coordinated control of distributed generators (DGs) inverters and active power filters (APFs) to compensate voltage harmonics in microgrids. For this, a hierarchical control system is proposed to mitigate voltage harmonic distortion. The hierarchical control structure includes two control levels: primary control and secondary control. Primary control consists of power controllers, selective virtual impedance loops and proportional-resonant (PR) voltage/current controllers. Secondary control manages the compensation of voltage harmonic distortion of sensitive load bus (SLB). Compensation of SLB harmonics by control of DGs may cause excessive voltage harmonics at the terminal of one or more of DGs interface inverters and/oroverloading of the inverters. After occurrence of each of these cases, active power filter (APF) participates in harmonic compensation and consequently the compensation efforts of DGs decrease to avoidexcessive harmonics or loading of DGs' inverters. Effectiveness of the proposed control scheme is demonstratedthrough simulation studies.