Wang Lu

Wang Lu

Auto-generated profile, based on publicly available information

Wang Lu

Institute of Modern Physics

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2018 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
HZH. W. Zhao
H. W. Zhao
Liangting SUNLiangting SUN
Liangting SUN
JGJ. W. Guo
J. W. Guo
WZW. H. Zhang
W. H. Zhang
WLW. Lu
W. Lu
DXD. Z. Xie
D. Z. Xie
The development of superconducting ECR source with higher magnetic fields and higher microwave frequency is the most straight forward path to achieve higher beam intensity and higher charge state performance. SECRAL, a superconducting third generation ECR ion source, is designed for 24-28 GHz microwave frequency operation with an innovative magnet configuration of sextupole coils located outside the three solenoids. SECRAL at 24 GHz has already produced a number of record beam intensities, such as 40Ar12+ 1.4 emA, 129Xe26+ 1.1 emA, 129Xe30+ 0.36 emA, and 209Bi31+ 0.68 emA. SECRAL-II, an upgraded version of SECRAL, was built successfully in less than 3 years and has recently been commissioned at full power of a 28 GHz gyrotron and three-frequency heating (28 + 45 + 18 GHz). New record beam intensities for highly charged ion production have been achieved, such as 620 eμA 40Ar16+, 15 eμA 40Ar18+, 146 eμA 86Kr28+, 0.5 eμA 86Kr33+, 53 eμA 129Xe38+, and 17 eμA 129Xe42+. Recent beam test results at SECRAL and SECRAL II have demonstrated that the production of more intense highly charged heavy ion beams needs higher microwave power and higher frequency, as the scaling law predicted. A 45 GHz superconducting ECR ion source FECR (a first fourth generation ECR ion source) is being built at IMP. FECR will be the world’s first Nb3Sn superconducting-magnet-based ECR ion source with 6.5 T axial mirror field, 3.5 T sextupole field on the plasma chamber inner wall, and 20 kW at a 45 GHz microwave coupling system. This paper will focus on SECRAL performance studies at 24-28 GHz and technical design of 45 GHz FECR, which demonstrates a technical path for highly charged ion beam production from 24 to 28 GHz SECRAL to 45 GHz FECR.

1 February 2020 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
Liangting SUNLiangting SUN
Liangting SUN
HZH. W. Zhao
H. W. Zhao
HZH. Y. Zhao
H. Y. Zhao
WLW. Lu
W. Lu
JGJ. W. Guo
J. W. Guo
ZLZ. W. Liu
Z. W. Liu
Ion source development over the last 20 years at the IMP is reviewed. For versatile purposes, several types of ion sources have been involved in the research and development work at the IMP, i.e., the highly charged ECR (Electron Cyclotron Resonance) ion source, intense microwave ion source or the 2.45 GHz intense beam ECR ion source, and laser ion source (LIS). In the development of ECR ion sources, SECRAL (Superconducting ECR ion source with Advanced design in Lanzhou), Lanzhou ECR ion source, and Lanzhou all permanent magnet ECR ion source series have been made, which can cover the operation microwave frequency range of 10–28 GHz. The LIS with an Nd:YAG laser with a maximum output energy of 8 J in 8 ns pulse duration has been developed for very intense short pulse ion beams from solid materials such as C, Ti, Ni, Ag, and so on. Microwave ion sources have been built to produce intense pulsed or direct current beams from several mA to 100 mA for either high intensity accelerators or applications. This paper will give an overview of the high intensity ion source development at the IMP, especially on the recent progress and new results, such as the status of the fourth generation ECR ion source (first fourth generation ECR ion source), the production of recorded highly charged ion beams with SECRAL sources, key technology research studies, and so on.

16 October 2015 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
Liangting SUNLiangting SUN
Liangting SUN
JGJ. W. Guo
J. W. Guo
WLW. Lu
W. Lu
WZW. H. Zhang
W. H. Zhang
YFY. C. Feng
Y. C. Feng
HZH. W. Zhao
H. W. Zhao
At Institute of Modern Physics (IMP), Chinese Academy of Sciences (CAS), the superconducting Electron Cyclotron Resonance (ECR) ion source SECRAL (Superconducting ECR ion source with Advanced design in Lanzhou) has been put into operation for about 10 years now. It has been the main working horse to deliver intense highly charged heavy ion beams for the accelerators. Since its first plasma at 18 GHz, R&D work towards more intense highly charged ion beam production as well as the beam quality investigation has never been stopped. When SECRAL was upgraded to its typical operation frequency 24 GHz, it had already showed its promising capacity of very intense highly charged ion beam production. And it has also provided the strong experimental support for the so called scaling laws of microwave frequency effect. However, compared to the microwave power heating efficiency at 18 GHz, 24 GHz microwave heating does not show the ω2 scale at the same power level, which indicates that microwave power coupling at gyrotron frequency needs better understanding. In this paper, after a review of the operation status of SECRAL with regard to the beam availability and stability, the recent study of the extracted ion beam transverse coupling issues will be discussed, and the test results of the both TE01 and HE11 modes will be presented. A general comparison of the performance working with the two injection modes will be given, and a preliminary analysis will be introduced. The latest results of the production of very intense highly charged ion beams, such as 1.42 emA Ar12+, 0.92 emA Xe27+, and so on, will be presented.

19 October 2015 in Review of Scientific Instruments
Verified
Journal Article
Closed access
JGJ. W. Guo
J. W. Guo
LSL. Sun
L. Sun
XNX. J. Niu
X. J. Niu
XZX. Z. Zhang
X. Z. Zhang
WLW. Lu
W. Lu
HZH. W. Zhao
H. W. Zhao
Over-sized round waveguide with a diameter about Ø33.0 mm excited in the TE01 mode has been widely adopted for microwave transmission and coupling to the ECR (Electron Cyclotron Resonance) plasma with the superconducting ECR ion sources operating at 24 or 28 GHz, such as SECRAL and VENUS. In order to study the impact of different microwave modes on ECRH (Electron Cyclotron Resonance Heating) efficiency and especially the production of highly charged ions, a set of compact and efficient TE01-HE11 mode conversion and coupling system applicable to 24 GHz SECRAL whose overall length is 330 mm has been designed, fabricated and tested. Good agreements between off-line tests and calculation results have been achieved, which indicates the TE01-HE11 converter meets the application design. The detailed results of the optimized coupling system will be presented in the paper.

1 January 2020 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
JGJ. W. Guo
J. W. Guo
Liangting SUNLiangting SUN
Liangting SUN
WLW. Lu
W. Lu
WZW. H. Zhang
W. H. Zhang
YFY. C. Feng
Y. C. Feng
HZH. W. Zhao
H. W. Zhao
The efficiency of the microwave-plasma coupling is a key issue to enhance the performance of electron cyclotron resonance ion sources (ECRISs) in terms of higher ion beam intensity yield. The coupling properties are affected by the microwave coupling scheme, especially for the high frequency (f > 20 GHz) and high power (P > 5 kW) ECR ion sources. Based on the study of 24 GHz SECRAL ion source performances working at different launching systems, a new microwave coupling scheme, called the Vlasov launcher, is proposed, which can not only realize efficient power matching and feeding but also enhance the microwave power distribution on the ECR surface. The first promising results are presented in this article. Then, a prototype dedicated to the next generation ECRIS is described.

9 December 2015 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
WLW. Lu
W. Lu
CQC. Qian
C. Qian
LSL. T. Sun
L. T. Sun
XZX. Z. Zhang
X. Z. Zhang
XFX. Fang
X. Fang
DXD. Xie
D. Xie
LECR4 (Lanzhou ECR ion source No. 4) is a room temperature electron cyclotron resonance ion source, designed to produce high current, high charge state ion beams for the SSC-LINAC injector (a new injector for sector separated cyclotron) at the Institute of Modern Physics. LECR4 also serves as a PoP machine for the application of evaporative cooling technology in accelerator field. To achieve those goals, LECR4 ECR ion source has been optimized for the operation at 18 GHz. During 2014, LECR4 ion source was commissioned at 18 GHz microwave of 1.6 kW. To further study the influence of injection stage to the production of medium and high charge state ion beams, in March 2015, the injection stage with pumping system was installed, and some optimum results were produced, such as 560 eμA of O7+, 620 eμA of Ar11+, 430 eμA of Ar12+, 430 eμA of Xe20+, and so on. The comparison will be discussed in the paper.