Kairan Zhu

Kairan Zhu

Auto-generated profile, based on publicly available information

Kairan Zhu

Department of Clinical Neurosciences & Hotchkiss Brain InstituteCumming School of Medicine, University of CalgaryCalgary, Alberta, Canada

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2023 in Stroke
Verified
Journal Article
Closed access
FBFouzi Bala
Fouzi Bala
MKManon Kappelhof
Manon Kappelhof
JOJohanna M. Ospel
Johanna M. Ospel
PCPetra Cimflova
Petra Cimflova
Qiu WuQiu Wu
Qiu Wu
FIfor the ESCAPE-NA1 Investigators
for the ESCAPE-NA1 Investigators
Background: Distal embolization (DE) is a common complication of endovascular treatment (EVT). We investigated the association of radiological thrombus characteristics and treatment details with DE. Methods: Patients with thin-slice (≤2.5 mm) baseline noncontrast computed tomography and computed tomography angiography from the ESCAPE-NA1 trial (Efficacy and Safety of Nerinetide for the Treatment of Acute Ischemic Stroke) were included. Thrombus annotation was performed manually on coregistered scans by experienced readers. We assessed thrombus location, distance from internal carotid artery terminus, length, perviousness, absolute attenuation, and hyperdense artery sign. In addition, we evaluated balloon guide catheter use during EVT, first-line EVT approach, the number of thrombectomy passes, and prior intravenous thrombolysis administration. DE was defined as the occurrence of emboli distal to the target artery or in new territories during EVT. The association between thrombus characteristics, treatment details, and DE was evaluated using descriptive statistics and multivariable mixed-effects logistic regression, resulting in adjusted odds ratios (aOR) with 95% CI. Interaction between IVT and radiological thrombus characteristics was assessed by adding interaction terms in separate models. Results: In total, 496 out of 1105 (44.9%) ESCAPE-NA1 patients were included. DE was detected in 251 out of 496 patients (50.6%). Patients with DE had longer thrombi (median, 28.5 [interquartile range, 20.8–42.3] mm versus 24.4 [interquartile range, 17.1–32.4] mm; P <0.01). There were no statistically significant differences in the other thrombus characteristics. Factors associated with DE were thrombus length (aOR, 1.02 [95% CI, 1.01–1.04]), balloon guide catheter use (aOR, 0.49 [95% CI, 0.29–0.85]), and number of passes (aOR, 1.24 [95% CI, 1.04–1.47]). In patients with hyperdense artery sign, IVT was associated with reduced odds of DE (aOR, 0.55 [95% CI, 0.31–0.97]), P for interaction=0.04. Conclusions: DE was associated with longer thrombi, no balloon guide catheter use, and more EVT passes. IVT was associated with a reduced risk of DE in patients with hyperdense artery sign. These findings may support treatment decisions on IVT and EVT approaches.

22 January 2018 in Energy & Fuels
Verified
Journal Article
Closed access
PSPhilip M. Singer
Philip M. Singer
ZCZeliang Chen
Zeliang Chen
LALawrence B. Alemany
Lawrence B. Alemany
GHGeorge J. Hirasaki
George J. Hirasaki
KZKairan Zhu
Kairan Zhu
TVTuan D. Vo
Tuan D. Vo

18 May 2023 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
KZK. Zhu
K. Zhu
FBF. Bala
F. Bala
JZJianhai Zhang
Jianhai Zhang
FBF. Benali
F. Benali
PCP. Cimflova
P. Cimflova
Qiu WuQiu Wu
Qiu Wu
BACKGROUND AND PURPOSE: Identifying the presence and extent of intracranial thrombi is crucial in selecting patients with acute ischemic stroke for treatment. This article aims to develop an automated approach to quantify thrombus on NCCT and CTA in patients with stroke. MATERIALS AND METHODS: A total of 499 patients with large-vessel occlusion from the Safety and Efficacy of Nerinetide in Subjects Undergoing Endovascular Thrombectomy for Stroke (ESCAPE-NA1) trial were included. All patients had thin-section NCCT and CTA images. Thrombi contoured manually were used as reference standard. A deep learning approach was developed to segment thrombi automatically. Of 499 patients, 263 and 66 patients were randomly selected to train and validate the deep learning model, respectively; the remaining 170 patients were independently used for testing. The deep learning model was quantitatively compared with the reference standard using the Dice coefficient and volumetric error. The proposed deep learning model was externally tested on 83 patients with and without large-vessel occlusion from another independent trial. RESULTS: The developed deep learning approach obtained a Dice coefficient of 70.7% (interquartile range, 58.0%–77.8%) in the internal cohort. The predicted thrombi length and volume were correlated with those of expert-contoured thrombi (r = 0.88 and 0.87, respectively; P < .001). When the derived deep learning model was applied to the external data set, the model obtained similar results in patients with large-vessel occlusion regarding the Dice coefficient (66.8%; interquartile range, 58.5%–74.6%), thrombus length (r = 0.73), and volume (r = 0.80). The model also obtained a sensitivity of 94.12% (32/34) and a specificity of 97.96% (48/49) in classifying large-vessel occlusion versus non-large-vessel occlusion. CONCLUSIONS: The proposed deep learning method can reliably detect and measure thrombi on NCCT and CTA in patients with acute ischemic stroke.

1 November 2015 in Physica E: Low-dimensional Systems and Nanostructures
Verified
Journal Article
Closed access
JSJiuxu Song
Jiuxu Song
HLHongxia Liu
Hongxia Liu
YGYingna Guo
Yingna Guo
KZKairan Zhu
Kairan Zhu

1 January 2010 in Procedia Engineering
Verified
Journal Article
Open access
JNJinping Niu
Jinping Niu
TSTao Su
Tao Su
XHXuehui He
Xuehui He
KZKairan Zhu
Kairan Zhu
HWHuiyang Wu
Huiyang Wu
Nuclear Quadrupole Resonance (NQR) is a nuclear physical phenomenon. It is a solid-state radio frequency (RF) spectroscopic technique that can be used to detect narcotics and highly explosive substances. Unfortunately, there are limitations to NQR. The NQR signal is restricted by the low signal-to-noise ratio (SNR) and the presence of strong RF interference (RFI). The RFI can be reduced dramatically by shielding the search coil indoors. In this paper, numerical accumulation method is used to improve SNR of the weak NQR signal. According to the frequency characteristic of the background signal, AR method is used to estimate the power spectrum of the experimental background data. Then, the generalized matched filter is studied to enhance explosive detection. The experimental results show good performance of the proposed algorithm

1 January 2010 in Procedia Engineering
Verified
Journal Article
Open access
KZKairan Zhu
Kairan Zhu
TSTao Su
Tao Su
XHXuehui He
Xuehui He
JNJinping Niu
Jinping Niu
Nuclear Quadrupole Resonance (NQR) is a solid-state radio frequency (RF) spectroscopic technique, allowing the detection of many high explosives and narcotics. Unlike metal detectors and ground penetrating radar (GPR), NQR detectors measure signals that are unique to the explosives, thus can provide a lower false alarm rate. The practical use of NQR is restricted by the inherently low signal-to-noise ratio (SNR) of the observed signals, a problem that is further exacerbated by the presence of strong RF interference (RFI), so a robust detection method is required. Singular value decomposition (SVD) based on Hankel matrix is proposed to detect the NQR signal in this paper. The original signal can be decomposed into the linear superposition of a series of component signals by SVD using Hankel matrix, and the process of constructing the Hankel matrix shows that a component T signal can be produced by averaging the elements on the inverse diagonal of the A i = σ i u i v i T . Then an eigendecomposition based spectrum estimator called “Multiple Signal Characterization” (MUSIC) is applied to estimate power spectrum of each component signal, so the RFI and the noise are canceled by using the priori knowledge of the NQR frequency. Finally, an average power detector is applied to detect NQR signal. The result using measured data shows that the proposed method can provide robust NQR detection performance.