Apiwat Boonkong

Apiwat Boonkong

Auto-generated profile, based on publicly available information

Apiwat Boonkong

Department of Computer Engineering, Faculty of Engineering, Khon Kaen University, Khon Kaen, Thailand

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 June 2024 in IEEE Access
Verified
Journal Article
Open access
NMNyi Nyi Myo
Nyi Nyi Myo
ABApiwat Boonkong
Apiwat Boonkong
KKKovit Khampitak
Kovit Khampitak
DHDaranee Hormdee
Daranee Hormdee
As Computer Vision technology has evolved rapidly these days, the implementation of object detection and instance segmentation has been presented in various areas. In computer-aided laparoscopic surgery, the segmentation of surgical instruments is one of the active research areas. This paper presents the implementation and comparative analysis of a real-time surgical instruments segmentation system by incorporating ByteTrack, a powerful object tracking system, within the YOLOv8, a state-of-the-art Deep Learning algorithm for object detection and segmentation, together with an instruments gesture analysis of the practical results. The instrument gestures have been categorized into separating, crossing, and overlapping cases according to the most common instrument gestures during the surgery. The datasets from the ROBUST-MIS 2019 challenge have been applied and annotated for training, validating, and blind testing in this study. Considering trade-offs among model complexity, speed, and accuracy, the medium version (YOLOv8m) has been chosen in this study for its comparative model complexity, design for working in real-time, and relative high accuracy. In order to validate the effectiveness of this research, real-time segmentation of surgical instruments has been performed with the streaming of laparoscopic gynecologic surgery on 5 donated soft-tissue cadaver cases. According to the experimental results, although YOLOv8 can provide very high-accuracy evaluation metrics for both F1-score and mAP (mean Average Precision), the segmentation accuracy results could have been further improved by incorporating the ByteTrack within the YOLOv8 algorithm. Owing to the 2-association scheme that has been designed for object tracking in ByteTrack, referring to the tracklet from the previous frame could recover missed segmentations that come with too low confidence values. The findings identify that the Modified model of incorporating ByteTrack with YOLOv8 could improve the F1-score from 0.89 to 0.92, which outperformed all of the previous studies on the ROBUST-MIS 2019 Challenge, and from 0.82 to 0.88 on the blinded captured dataset from live streaming videos with a real-time segmentation speed of approximately 45 FPS (Frames Per Second), which is sufficient for a real-time application as opposed to 60 FPS from only the YOLOv8 algorithm. From the instrument gestures result analysis, ByteTrack could improve the segmentation performance in all gesture categories: separating, crossing, and overlapping. However, the remaining segmentation failures mostly lie in crossing and overlapping gestures.

7 July 2023 in IEEE Access
Verified
Journal Article
Open access
ABApiwat Boonkong
Apiwat Boonkong
KKKovit Khampitak
Kovit Khampitak
DHDaranee Hormdee
Daranee Hormdee
Nowadays, with the current technological forces that have been shaping our bright future, one of these is Computer Vision. And this statement is true across various matters, including laparoscopic gynecology, where computer-aided procedures for object recognition could offer surgeons the opportunity to ease up on on-going surgeries and/or to practice their surgical skills with offline surgeries. However, most of the previous work has been retrospective and focused on methodology from a computational viewpoint with minimal datasets showing how Computer Vision can be utilized for laparoscopic surgery. The main purpose of this paper is not just to evaluate state-of-the-art object detection models for uterus detection, but also to emphasize clinical application via the collaboration between surgeons and peopleware which is important in the further development and adoption of this technology, leading to improved clinical outcomes in Laparoscopic Gynecology. Two experiment phases have been conducted. Phase#1 applied 8 different Deep Learning models for uterus detection and were tested on the dataset, obtained from 40 public YouTube videos in Laparoscopic Gynecologic Surgery. In order to prove this new technology before performing on patients, and also due to the ethics of human experimentation, extensive testing on soft-tissue cadavers has been used, hence Phase#2 which performed the best models from the first experiment phase serving a real-time streaming feed during 4 soft-tissue cadaver laparoscopic surgeries, which theoretically is the best approach as they are the closest to humans in terms of shape and structure. Four models, pre-trained on the COCO 2017 Dataset on TensorFlow Model Zoo: CenterNet; EfficientDet; SSD; and Faster R-CNN; plus YOLOv4 on Darknet Framework, along with YOLOv4, YOLOv5 and YOLOv7 on Pytorch have been scrutinized here. The inference time (in FPS: Frame Per Second), F1-score and AP (Average Precision) have been used as evaluation metrics. The results exhibited that all 3 YOLOs on PyTorch outperformed all effectiveness metrics, including with great inference speed which is suitable for real-time surgeries. Lastly, a by-product but also useful contribution of this work, is the annotated dataset on uterus detection from both public videos and live feed on cadaver surgeries.

30 April 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SNSongphon Namkhun
Songphon Namkhun
KKKovit Khampitak
Kovit Khampitak
ABApiwat Boonkong
Apiwat Boonkong
DHDaranee Hormdee
Daranee Hormdee
In gynecologic surgery, a uterine manipulator is one of the instruments used to perform the laparoscopy. Throughout the past decade, a number of robotic technology applications used for uterine manipulation during surgery have been designed with the aim of increasing the efficiency, improving the precision, and reducing the workload of medical assistants. Although the RCM (Remote Center of Motion) mechanism is one of the key features in a Minimally Invasive Surgical (MIS) robot, the preliminary result in this study, in which the RCM mechanism was applied in a uterine manipulation robot, proved that this may cause unpleasant sensations such as irritation or harm to the nearby area during such manipulation. Therefore, a design of a non-RCM 2-DoF (Degree of Freedom) Robotic Uterine Manipulation System, in cooperation with an existing, reusable and tiltable-tip uterine manipulator, for laparoscopic gynecologic surgery has been proposed and evaluated via a mathematical model along with numerical analysis, a 3D uterus model, and a 1:1 uterus manikin model in order to demonstrate the use of the essential functions. According to the experimental results, the maximum load of 500 g has been handled well by the prototype, with the movement ranges of ±150° in the roll panel and ±90° in the pitch panel (0∼90° for anteversion and 0∼−90° for retroversion, if needed, which can be achieved by rotating the instrument to the other side). Furthermore, to verify this new design prior to its use on patients, and also in consideration of the ethics of human experimentation, through extensive testing on five donated soft-tissue cadavers, the proposed robot received positive feedback from all five surgeons performing the experiments and could offer effective uterine manipulation at the angular velocity of 4 °/s (0.67 RPM) with steady delineation of the vaginal fornices to create necessary motions in the pitch and roll panels of 30∼80° and ±15°, respectively, providing efficient visualization of the uterus. These features make this robot a valuable addition to the surgical instruments available to gynecologic surgeons.

29 November 2024 in IEEE Access
Verified
Journal Article
Open access
ABApiwat Boonkong
Apiwat Boonkong
KKKovit Khampitak
Kovit Khampitak
PKPiroon Kaewfoongrungsi
Piroon Kaewfoongrungsi
SNSongphon Namkhun
Songphon Namkhun
DHDaranee Hormdee
Daranee Hormdee
Laparoscopic tubal sterilization is a widely used method for permanent contraception, where accurately identifying the uterus and fallopian tubes is crucial. However, this process becomes more difficult when these structures are obscured or partially hidden during surgery. Conventional imaging techniques often struggle to accurately identify anatomical features in such scenarios. In contrast, recent progress in deep learning, particularly with the You Only Look Once (YOLO) algorithm, has shown promising results by enabling real-time object detection in medical imaging. By incorporating KeyPoint detection with the newest YOLOv10 version, the system’s ability to detect and pinpoint anatomical landmarks is significantly improved, even when occlusions are present. This study presents a novel approach that merges YOLOv10 with KeyPoint detection to reliably identify the uterus and fallopian tubes in real-time laparoscopic footage, even when these structures are partially hidden. The method also identifies the Ampulla and Isthmus at the Uterine-Tubal junction, even in cases where visualization is obstructed. Additionally, an ellipse estimation technique is applied to further enhance detection under occluded conditions by estimating the uterus’s position and orientation when it is not fully visible. The results highlight the potential for real-time application of this system in clinical settings, marking a step forward in AI-assisted laparoscopic surgery.