Selem Alvarenga Vilela

Selem Alvarenga Vilela

Auto-generated profile, based on publicly available information

Selem Alvarenga Vilela

Faculdade São Leopoldo Mandic

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 February 2022 in Research, Society and Development
Verified
Journal Article
Open access
PDF file
SVSelem Alvarenga Vilela
Selem Alvarenga Vilela
AFAline Batista Gonçalves Franco
Aline Batista Gonçalves Franco
GCGeraldo Alberto Pinheiro de Carvalho
Geraldo Alberto Pinheiro de Carvalho
SDSérgio Candido Dias
Sérgio Candido Dias
SJSilvio Mecca Junior
Silvio Mecca Junior
CMCaio Marques Martins
Caio Marques Martins
The aim of this study is to analyze the compressive strength of occlusal splints manufactured with three different liquid resins in a 3D printer and in three angles of orientation. The resins used here are (n=12): Resilab Clear (Wilcos do Brasil, Petrópolis, RJ, Brazil), Prizma Smart Print Bio (Makertech Labs, Tatuí, SP, Brazil), and Cosmos Splint (Yller Biomateriais, Pelotas, RS, Brazil); each resin group are divided into three subgroups according to orientation of manufacture: 0, 45 and 90 degrees. A dental manikin was scanned and the file was used to manufacture a steel hemiarch model. This model was used to design the occlusal splints and as a basis for the tests. The splints were designed with flat occlusal surface and minimum thickness of 2 mm. The compressive test was performed with constant force of 200N, velocity of 0.5 mm/min, along the entire occlusal surface until fracture. Results show no difference between the resins, regardless of orientation of manufacture. The orientation showed no intragroup effect for resins Prizma Smart Print Bio and Resilab Clear; the resin Cosmos showed larger compressive strength for the samples manufactured at 45 degrees than at 0 degree. The 90-degree samples were intermediary and showed no difference from other angles. This study shows that the three resins had similar behavior in terms of compressive strength, except for the intragroup effect of orientation of Cosmos Splint resin, where plates manufactured at 0 degree performed worse than those at 45 degrees.

9 March 2022 in Research, Society and Development
Verified
Journal Article
Open access
PDF file
FFFrancisco Fernando Massola Filho
Francisco Fernando Massola Filho
AFAmanda Gonçalves Franco
Amanda Gonçalves Franco
GCGeraldo Alberto Pinheiro de Carvalho
Geraldo Alberto Pinheiro de Carvalho
SDSérgio Candido Dias
Sérgio Candido Dias
ERElimario Venturin Ramos
Elimario Venturin Ramos
AFAline Batista Gonçalves Franco
Aline Batista Gonçalves Franco
The aim of this study is to assess how shear strength of Ultra Translucent Multi Layered Zirconia Katana (UTML) is affected by the conditioning with 10% hydrofluoric acid combined with the current surface treatment protocol: air, primer containing 10-MDP, and cement. Samples of UTML Zirconia Katana were machined to measure 5x5x10 units of measurement, attached, and divided into two groups. In the control group, samples were treated with 27 um aluminum oxide blasting at 4 bars, application of Zr primer containing 10-MDP and, finally, cement Panávia V5. In the experimental group, samples were also treated with 10% hydrofluoric acid following blasting and prior to the primer application. The test specimens were submitted to shear mechanical strength test on a universal testing machine EMIC DL2000 (EMIC, São Paulo, Brazil), surface analysis with Scanning Electron Microscope (SEM) (Sputter Coaster Emitech, K450) and surface roughness. Results showed that the bond strength of specimens conditioned with acid was 41% higher (p = 0.031). Student’s t test showed that the samples conditioned with acid were rougher than those without conditioning (p = 0.045). Microscopic analysis showed surface alterations on samples conditioned with acid. It is possible to conclude that the group conditioned with hydrofluoric acid showed better adhesive behavior.