Ming Liu

Ming Liu

Auto-generated profile, based on publicly available information

Ming Liu

Department of Modern Physics, University of Science and Technology of China, Hefei 230026, China

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2017 in Review of Scientific Instruments
Verified
Journal Article
Closed access
MLMunan Lin
Munan Lin
MLMing Liu
Ming Liu
GZGuanghui Zhu
Guanghui Zhu
PSPeiyun Shi
Peiyun Shi
JZJian Zheng
Jian Zheng
XSXuan Sun
Xuan Sun
We describe a field reversed configuration (FRC) experiment featuring in-vessel θ-pinch coils and open-field-line plasmas confined in a tandem mirror. Two FRCs, formed near the west and the east mirror throats of a central cell, are ejected toward the mid-plane for colliding and merging. Each FRC consists of four groups of pulsed power supplies and four groups of coils, having diameters 35, 35, 40, and 45 cm. The rise time of the main reversal field is 7.15 μs, and the maximum voltage is 40 kV with total currents of 416 kA, corresponding to a magnetic field of 1690 G. The total capacitive stored energy is 115.2 kJ. A fast pulse gas injection system was designed and tested to inject neutral gas into the FRC formation region with controlled directions. The successful installation of the θ-pinch coils inside the vacuum vessel offers greater freedom for diagnostics and control instruments as well as preserving magnetic tandem mirror configuration. The magnetic field reversal is confirmed by internal magnetic field measurements. The plasma temperature, density, and lifetime are, respectively, ∼100 eV, ∼3.0 × 1018 m−3, and ∼300 μs for the current operating conditions.

1 August 2018 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
MLMing Liu
Ming Liu
HYHongshen Yi
Hongshen Yi
GZGuanghui Zhu
Guanghui Zhu
ZYZhida Yang
Zhida Yang
MLMunan Lin
Munan Lin
XSXuan Sun
Xuan Sun
In this paper, we report the results of ion cyclotron resonance frequency (ICRF) heating in the central cell of a fully axisymmetric tandem mirror. With a total power of 100 kW radiated by double half-turn and half-turn antennas, the plasma diamagnetism increases by 15-fold, with a corresponding peak β ⊥ ∼2%, density ∼ 1.5 × 10 18 m − 3 , and total temperature ∼60 eV. The effects of the magnetic configuration on resonance heating and wave emission are studied by varying the magnetic fields at the midplane and at the location of the antennas, respectively; the results confirm that the magnetic beach configuration is key to successful ICRF heating. The axial phase speed measurements suggest that the excited wave is a slow wave in the plasma core and a fast wave at the edge.

1 April 2018 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
HYHongshen Yi
Hongshen Yi
MLMing Liu
Ming Liu
PSPeiyun Shi
Peiyun Shi
ZYZhida Yang
Zhida Yang
GZGuanghui Zhu
Guanghui Zhu
XSXuan Sun
Xuan Sun
A new medium-sized washer gun is developed for a plasma start-up in a fully axisymmetric mirror. The gun is positioned at the east end of the Keda Mirror with AXisymmetricity facility and operated in the pulsed mode with an arc discharging time of 1.2 ms and a typical arc current of 8.5 kA with 1.5 kV discharge voltage. To optimize the operation, a systematic scan of the neutral pressure, the arc voltage, the bias voltage on a mesh grid 6 cm in front of the gun and an end electrode located on the west end of mirror, and the mirror ratio was performed. The streaming plasma was measured with triple probes in the three mirror cells and a diamagnetic loop in the central cell. Floating potential measurements suggest that the plasma could be divided into streaming and mirror-confined plasmas. The floating potential for the streaming plasma is negative, with an electric field pointing inwards. The mirror-confined plasma has a typical lifetime of 0.5 ms.

1 May 2017 in Review of Scientific Instruments
Verified
Journal Article
Closed access
MLMing Liu
Ming Liu
HYHongshen Yi
Hongshen Yi
MLMunan Lin
Munan Lin
YWYanpeng Wang
Yanpeng Wang
PSPeiyun Shi
Peiyun Shi
XSXuan Sun
Xuan Sun
In this paper, we describe the engineering work involved in constructing two ion cyclotron resonance heating (ICRH) systems for use in the Keda Mirror with AXisymmetry tandem mirror experiment. Because they offer an effective and robust heating method, ICRH systems have been widely used in a variety of plasma experiments. The goal of our system is to heat the hydrogen plasma contained in the central cell using the fundamental ion cyclotron frequency. Both systems can deliver a radiofrequency power of ∼120 kW with adjustable operating frequencies that are tuned to be slightly lower than their local ion cyclotron frequencies. Two types of antennas are installed in the central cell in an attempt to launch both slow and fast waves. The heating mechanism is reliant on the magnetic beach effect for slow waves.

1 August 2017 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
MLMunan Lin
Munan Lin
MLMing Liu
Ming Liu
GZGuanghui Zhu
Guanghui Zhu
YWYanpeng Wang
Yanpeng Wang
PSPeiyun Shi
Peiyun Shi
XSXuan Sun
Xuan Sun
A high voltage pulse generator based on a silicon-controlled rectifier has been designed and implemented for a field reversed configuration experiment. A critical damping circuit is used in the generator to produce the desired pulse waveform. Depending on the load, the rise time of the output trigger signal can be less than 1 μs, and the peak amplitudes of trigger voltage and current are up to 8 kV and 85 A in a single output. The output voltage can be easily adjusted by changing the voltage on a capacitor of the generator. In addition, the generator integrates an electrically floating heater circuit so it is capable of triggering either pseudosparks (TDI-type hydrogen thyratron) or ignitrons. Details of the circuits and their implementation are described in the paper. The trigger generator has successfully controlled the discharging sequence of the pulsed power supply for a field reversed configuration experiment.

1 March 2025 in Physics of Plasmas
Verified
Journal Article
Open access
CHChaoqi Hu
Chaoqi Hu
WQWeijian Qin
Weijian Qin
YCYutao Chen
Yutao Chen
ZYZhida Yang
Zhida Yang
BRBaoming Ren
Baoming Ren
XSXuan Sun
Xuan Sun
The field-reversed configuration (FRC), a compact toroidal plasmoid, has a range of potential applications, particularly in nuclear fusion, space propulsion, and plasma research. Various formation methods have been developed to create the magnetic topology required for stable plasma confinement. Here, we propose and investigate a novel formation method using a plasma gun as the plasma source and a DC background magnetic field as the bias field. This approach reduces the device's dependence on high-voltage pulse power supplies for FRC formation and enhances magnetic flux retention. In our experiments, we observed the splitting of elongated FRCs. Specifically, FRCs with an elongation greater than 1.7 and low trapped magnetic flux—a central-to-external magnetic field ratio below 0.6—tended to split during translation. This study demonstrates a new technical scheme for FRC formation, and the experimental results may contribute to the FRC optimization and stability control during translation and compression.