Yandao Huang

Yandao Huang

Auto-generated profile, based on publicly available information

Yandao Huang

Hong Kong University of Science and Technology

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 September 2021 in IEEE Transactions on Mobile Computing
Verified
Journal Article
Closed access
FLFei Luo
Fei Luo
SKSalabat Khan
Salabat Khan
YHYandao Huang
Yandao Huang
KWKaishun Wu
Kaishun Wu
A wide diversity of sensors has been applied in human activity recognition. These sensors generate enormous amounts of data during human activity monitoring. The long-distance data traveling between sensors and servers increases the costs of bandwidth and latency. However, human activity recognition has a high demand for real-time processing. Recently, edge computing is surging to solve this problem by moving computation and data storage closer to the sensor devices, rather than relying on a central server/cloud. Edge servers are usually designed for low power, low cost, and low computation. They do not support computation-intensive deep learning algorithms or will result in high latency. Fortunately, the development of binarized neural networks enables edge intelligence which supports AI running at the network edge for real-time applications. In this paper, we implement a binarized neural network (BinaryDilatedDenseNet) to enable low-latency and low-memory human activity recognition at the network edge. We applied the BinaryDilatedDenseNet on three sensor-based human activity recognition datasets and evaluated it with four metrics. In comparison, the BinaryDilatedDenseNet outperforms the related work and other three binarized neural networks in accuracy and saves 10 memory and 4.5--8 inference time compared to the FPDilatedDenseNet(the full-precision version of the BinaryDilatedDenseNet).

12 November 2023
Verified
Conference Paper
Open access
CLChenggao Li
Chenggao Li
QHQianyi Huang
Qianyi Huang
YZYuxuan Zhou
Yuxuan Zhou
YHYandao Huang
Yandao Huang
QHQingyong Hu
Qingyong Hu
QZQian Zhang
Qian Zhang

1 June 2019
Verified
Conference Paper
Closed access
YHYandao Huang
Yandao Huang
WCWenqiang Chen
Wenqiang Chen
HCHongjie Chen
Hongjie Chen
Lu WangLu Wang
Lu Wang
KWKaishun Wu
Kaishun Wu
The inevitable aging trend of the world’s population brings a lot of challenges to the health care for the elderly. For example, it is difficult to guarantee timely rescue for a single-resided elder who falls at home. Under this circumstance, a reliable automatic fall detection machine is in great need for emergent rescue. However, the state-of-the-art fall detection systems are suffering from serious privacy concerns, having a high false alarm or being cumbersome for users. In this paper, we propose a device-free fall detection system, namely G-Fall, based on geophones. We first decompose the falling mode and characterize it with time-dependent floor vibration features. By leveraging Hidden Markov Model (HMM), our system is able to recognize the fall event precisely and achieve training-free recognition. It requires no training from the elderly but only an HMM template learned in advance through a small number of training samples. To reduce the false alarm rate, we propose a novel reconfirmation mechanism, namely Energy-of-Arrival (EoA) positioning to assist in recognizing a human’s fall. Extensive experiments have been conducted on 12 human subjects. The results demonstrate that G-Fall achieves a 95.74% recognition precision with a false alarm rate of 5.30% on average. Furthermore, with the assistance of EoA, the false alarm rate is reduced to nearly 0%.

19 December 2024 in Communications Engineering
Verified
Journal Article
Open access
PDF file
YHYandao Huang
Yandao Huang
LCLin Chen
Lin Chen
CLChenggao Li
Chenggao Li
JPJunyao Peng
Junyao Peng
QHQingyong Hu
Qingyong Hu
QZQian Zhang
Qian Zhang
Continuous monitoring of nocturnal blood pressure is crucial for hypertension management and cardiovascular risk assessment. However, current clinical methods are invasive and discomforting, posing challenges. These traditional techniques often disrupt sleep, impacting patient compliance and measurement accuracy. Here we introduce a non-contact system for continuous monitoring of nocturnal blood pressure, utilizing ballistocardiogram signals. The key component of this system is the utilization of advanced, flexible fiber optic sensors designed to capture medical-grade ballistocardiogram signals accurately. Our artificial intelligence model extracts deep learning and fiducial features with physical meanings and implements an efficient, lightweight personalization scheme on the edge device. Furthermore, the system incorporates a crucial algorithm to automatically detect the user’s sleeping posture, ensuring accurate measurement of nocturnal blood pressure. The model underwent rigorous evaluation using open-source and self-collected datasets comprising 158 subjects, demonstrating its effectiveness across various blood pressure ranges, demographic groups, and sleep states. This innovative system, suitable for real-world unconstrained sleeping scenarios, allows for enhanced hypertension screening and management and provides new insights for clinical research into cardiovascular complications.

30 August 2023 in IEEE Transactions on Mobile Computing
Verified
Journal Article
Closed access
FLFei Luo
Fei Luo
SKSalabat Khan
Salabat Khan
ALAnna Li
Anna Li
YHYandao Huang
Yandao Huang
KWKaishun Wu
Kaishun Wu
Human activity recognition (HAR) has become a research hotspot because of its wide range of application prospects. It has higher requirements for real-time and powerefficient processing. However, a large amount of data transfer between sensors and servers, and computation-intensive recognition models hinder the implementation of real-time HAR systems. Recently, edge computing has been proposed to address this challenge by moving computational and data storage resources to the sensors, rather than depending on a centralized server/cloud. In this paper, we investigated binary neural networks for edge intelligence-enabled HAR using radar point cloud. Point cloud can provide 3-dimensional spatial information, which is helpful to improve recognition accuracy. Time-series point cloud also brings challenges, such as larger data volume, 4-dimensional data processing, and more intensive computation. To tackle these challenges, we adopt the 2-dimensional histograms for point cloud multi-view processing and propose the EdgeActNet, a binary neural network for point cloud-based human activity classification on edge devices. In the evaluation, the EdgeActNet achieved the best results with average accuracies of 97.63% on the MMActivity dataset and 95.03% on the point cloud samples of the DGUHA dataset respectively; and saved 16.9× memory consumption and 11.5× inference time compared to its full-precision version. Our work also is the first to apply 2D histogram-based multi-view representation and BNNs for timeseries point cloud classification.

20 October 2021 in IEEE Transactions on Mobile Computing
Verified
Journal Article
Closed access
YHYongzhi Huang
Yongzhi Huang
KCKaixin Chen
Kaixin Chen
YHYandao Huang
Yandao Huang
Lu WangLu Wang
Lu Wang
KWKaishun Wu
Kaishun Wu
Traditional liquid identification instruments are often unavailable to the general public. This paper shows the feasibility of identifying unknown liquids with commercial lightweight devices, such as a smartphone. The wisdom arises from the fact that different liquid molecules have various viscosity coefficients, so they need to overcome dissimilitude energy barriers during relative motion. With this intuition in mind, we introduce a novel model that measures liquids’ viscosity based on active vibration. The idea sounds straightforward, yet, it is challenging to build up a robust system utilizing the built-in accelerometer in smartphones. Practical issues include under-sampling, self-interference, and volume change impact. Instead of using machine learning techniques, we tackle these issues through multiple signal processing stages to reconstruct the original signals and cancel out the interference. Our approach achieved the liquid viscosity estimates with a mean relative error of 2.3% and distinguish 30 kinds of liquid with an average accuracy of 97.33%.