3 February 2017 in Analytical Chemistry
11 May 2018 in Analytical Chemistry
13 July 2017 in Analytical Chemistry
15 January 2021 in Journal of Analytical Atomic Spectrometry
The determination of essential micronutrient elements (e.g., Fe, Mn, B, Zn and Cu) in soil is of key importance to evaluate the nutritional status of soil. Conventional single pulse LIBS methods used for determining these elements cannot satisfy the requirements of accuracy and sensitivity due to the serious matrix effect and self-absorption effect. In this work, laser-induced breakdown spectroscopy assisted by laser-induced fluorescence (LIBS-LIF) was introduced to determine the essential micronutrient elements in soil. The linearity coefficients R2 were all above 0.99 and the limits of detection for Fe, Mn, B, Zn and Cu reached 22.56, 1.23, 0.36, 1.21 and 0.48 ppm, respectively. The results demonstrate that LIBS-LIF can be an effective method for high-accuracy and high-sensitivity determination of essential micronutrient elements in soil.
23 September 2021 in Journal of Analytical Atomic Spectrometry
The toxicity of lead (Pb) in water is known to affect cellular components, enzymatic machinery and genomic instability. The detection of lead in water is of great significance. In this study, a method called resonant surface-enhanced LIBS (R-SENLIBS) was proposed to improve the LoD of lead in aqueous solutions. RLIBS was coupled with SENLIBS in this method. Lead in aqueous solutions was compounded in a concentration range of 0.01 to 0.6 mg L−1. The calibration curve of these solutions was built. The value of coefficients of determination (R2) was as high as 0.996 and an LoD of 0.0021 mg L−1 was achieved for the linear calibration range of 0.01 to 0.2 mg L−1. Compared to previously published studies involving lead detection by LIBS, the analysis capability of R-SENLIBS proposed in this study is superior to that of those approaches in these studies. Moreover, the calibration range and LoD in this study meet the drinking water sanitation standard of China (0.01 mg L−1 for Pb, GB5749-2006) and WHO guidelines on lead. Trueness evaluation was carried out by spike and recovery experiments in a real sample of tap water, resulting in recovery values in the range of 101–110%. Spectral comparison indicated that impurities in the substrate and real aqueous solution had little influence on the lead signal in R-SENLIBS. The enhancement mechanism of R-SNELIBS was discussed. The on-resonance excitation and stratified structure of the sample are the two main reasons that lead to a valid signal of Pb. In summary, the method proposed in this study can be an alternative for lead analysis in drinking-water monitoring.
8 December 2020 in Journal of Analytical Atomic Spectrometry
SiO molecular emission which could hardly be detected in LIBS was enhanced by LIBS assisted with laser-induced molecular fluorescence and investigated for silicon determination in steel.