1 January 2013 in Disease Markers
Background. Cardiac surgery-associated acute kidney injury (CSA-AKI) depicts a major complication after cardiac surgery using cardiopulmonary bypass (CPB).Objective. CSA-AKI has clearly been linked to increased perioperative morbidity and mortality. Dysregulations of vasomotor tone are assumed to be causal for CSA-AKI. While catechol-O-methyltransferase (COMT) is involved in metabolizing catecholamines, a single-nucleotide polymorphism (SNP) in the COMT gene leads to different enzyme activities according to genotype. Pilot studies found associations between those COMT genotypes and CSA-AKI.Methods. We prospectively included 1741 patients undergoing elective cardiac surgery using cardiopulmonary bypass (CPB). Patients were genotyped for COMT-Val158Met-(G/A) polymorphism (rs4680).Results. Demographic characteristics and procedural data revealed no significant differences between genotypes. No association between COMT genotypes and the RIFLE criteria could be detected. A multiple linear regression analysis for postoperative creatinine increase revealed highly significant associations for aortic cross-clamp time (), CPB time (), norepinephrine (), and age (). No associations were found for COMT genotypes or baseline creatinine. With anand a sample size of 1741, the observed power of the regression analysis was >99%.Conclusions. Based on our results, we can rule out an association between the COMT-Val158Met-(G/A) polymorphism and the appearance of CSA-AKI.
3 March 2017 in Australasian Physics & Engineering Sciences in Medicine
17 December 2017 in BioMed Research International
According to the European Resuscitation Council guidelines, the use of mechanical chest compression devices is a reasonable alternative in situations where manual chest compression is impractical or compromises provider safety. The aim of this study is to compare the performance of a recently developed chest compression device (Corpuls CPR) with an established system (LUCAS II) in a pig model. Methods. Pigs ( = 5/group) in provoked ventricular fibrillation were left untreated for 5 minutes, after which 15 min of cardiopulmonary resuscitation was performed with chest compressions. After 15 min, defibrillation was performed every 2 min if necessary, and up to 3 doses of adrenaline were given. If there was no return of spontaneous circulation after 25 min, the experiment was terminated. Coronary perfusion pressure, carotid blood flow, end-expiratory CO2, regional oxygen saturation by near infrared spectroscopy, blood gas, and local organ perfusion with fluorescent labelled microspheres were measured at baseline and during resuscitation. Results. Animals treated with Corpuls CPR had significantly higher mean arterial pressures during resuscitation, along with a detectable trend of greater carotid blood flow and organ perfusion. Conclusion. Chest compressions with the Corpuls CPR device generated significantly higher mean arterial pressures than compressions performed with the LUCAS II device.
10 October 2013 in Australasian Physics & Engineering Sciences in Medicine
30 May 2013 in International Journal of Biomaterials
Background. Protocols using chemical reagents for scaffold decellularization can cause changes in the properties of the matrix, depending on the type of tissue and the chemical reagent. Technologies using physical techniques may be possible alternatives for the production grafts with potential superior matrix characteristics. Material and Methods. We tested four different technologies for scaffold decellularization. Group 1: high hydrostatic pressure (HHP), 1 GPa; Group 2: pressure shift freezing (PSF); Group 3: pulsed electric fields (PEF); Group 4: control group: detergent (SDS). The degree of decellularization was assessed by histological analysis and the measurement of residual DNA. Results. Tissue treated with PSF showed a decellularization with a penetration depth (PD) of 1.5mm and residual DNA content of . HHD treatment caused a PD of 0.2mm with a residual DNA content of . PD in PEF was 0.5mm, and the residual DNA content was . In the SDS group, PD was found to be 5mm, and the DNA content was determined at . Conclusion. PSF showed promising results as a possible technique for scaffold decellularization. The penetration depth of PSF has to be optimized, and the mechanical as well as the biological characteristics of decellularized grafts have to be evaluated.
24 February 2017 in Medical Engineering & Physics
Investigations of compressive frequency, duty cycle, or waveform during CPR are typically rooted in animal research or computer simulations. Our goal was to generate a mechanical model incorporating alternate stiffness settings and an integrated blood flow system, enabling defined, reproducible comparisons of CPR efficacy. Based on thoracic stiffness data measured in human cadavers, such a model was constructed using valve-controlled pneumatic pistons and an artificial heart. This model offers two realistic levels of chest elasticity, with a blood flow apparatus that reflects compressive depth and waveform changes. We conducted CPR at opposing levels of physiologic stiffness, using a LUCAS device, a motor-driven plunger, and a group of volunteers. In high-stiffness mode, blood flow generated by volunteers was significantly less after just 2min of CPR, whereas flow generated by LUCAS device was superior by comparison. Optimal blood flow was obtained via motor-driven plunger, with trapezoidal waveform.