27 March 2023 in Journal of Seismology
The east of Cali is composed of loose sand deposits with high water table levels. This condition and the high seismic hazard of the city make cyclic liquefaction one of the main hazards in the city, which may affect more than 600,000 citizens and important infrastructures such as the city’s main drinking water treatment plants. Therefore, it was decided to design and implement a seismic monitoring center to study the behavior of liquefiable soils under local seismogenic conditions, in which subduction earthquakes predominate. First, more than 130 earthquakes from two seismic monitoring centers with liquefiable layers in the USA were studied to determine the requirements for the adequate design of the monitoring center. Then, a robust geotechnical and seismic characterization of the study area including SPT, CPTu, and seismic and ambient noise tests were carried out. From this information, the specifications and location of the instruments and, in general, the characteristics of the monitoring center were defined. The monitoring center has been planned to be established in two stages, and the first one has already been built and commissioned. The implementation of the first stage allowed to adequately record 35 earthquakes from different seismogenic sources, most of them from subduction earthquakes, and to verify that the potentially liquefiable layer remains saturated throughout the year. Subsequent ground motion sensors will allow to deeply study and understand large shear strains and excess pore pressures generation in the soil deposit, as well as their relationships with different intensity measures. The experience shared herein can benefit the design, construction, and operation of other seismic monitoring centers across the world.
4 October 2026 in SSRN Electronic Journal
Linear-elastic analyses of high-rise buildings with deep basements can predict large seismic earth pressures that are seldom reflected in post-earthquake damage. This study examines how structural nonlinearity modifies forces transmitted through coupled soil–basement–structure systems. Twenty plane-strain finite-element analyses were performed for 25- and 55-story buildings with three- and seven-level basements embedded in Santiago Gravel and Berlin Sand and subjected to a deconvolved record from the 2010 Maule earthquake. The soil was nonlinear throughout, while the vertical reinforced-concrete elements of the superstructure and basement were represented as linear elastic or nonlinear. The response was assessed from near-wall soil-stress envelopes, retained-depth seismic thrust, regional resultants, plastic-point maps, H₁ force-to-acceleration estimates and coherence, and Stockwell representations. Under the Rapel excitation, structural nonlinearity reduced peak seismic thrust in all eight paired configurations by 6.62–20.98% for seven-level basements and 20.28–34.95% for three-level basements. Plastic-point maps for S55–N7 confirmed activation of the nonlinear structural representation and showed a greater vertical extent in Berlin Sand. The response was depth-dependent, and local peak demands increased in some wall regions despite the lower seismic thrust. For S25, the first-mode force-transfer peak decreased by 22.90–41.00%, whereas second-mode reductions were smaller. For S55, the second-mode component decreased consistently, while the first-mode response depended on the soil profile. Stockwell results for S55–N7 showed an initial second-mode contribution followed by a first-mode component attenuated by structural nonlinearity, with a clearer effect in Berlin Sand. These findings support system-level inelastic relief and show that seismic thrust and its depthwise distribution should be evaluated separately.