Jonghwan Yoon

Jonghwan Yoon

Auto-generated profile, based on publicly available information

Jonghwan Yoon

Department of Physics and Chemistry DGIST Daegu 42988 Republic of Korea

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 February 2024 in Small Methods
Verified
Journal Article
Open access
XHXinghao Hu
Xinghao Hu
KKKeonmok Kim
Keonmok Kim
AAAbbas Ali
Abbas Ali
HKHyeonseol Kim
Hyeonseol Kim
YKYumin Kang
Yumin Kang
CheolGi KimCheolGi Kim
CheolGi Kim
Field‐driven transport systems offer great promise for use as biofunctionalized carriers in microrobotics, biomedicine, and cell delivery applications. Despite the construction of artificial microtubules using several micromagnets, which provide a promising transport pathway for the synchronous delivery of microrobotic carriers to the targeted location inside microvascular networks, the selective transport of different microrobotic carriers remains an unexplored challenge. This study demonstrated the selective manipulation and transport of microrobotics along a patterned micromagnet using applied magnetic fields. Owing to varied field strengths, the magnetic beads used as the microrobotic carriers with different sizes revealed varied locomotion, including all of them moving along the same direction, selective rotation, bidirectional locomotion, and all of them moving in a reversed direction. Furthermore, cells immobilized with magnetic beads and nanoparticles also revealed varied locomotion. It is expected that such steering strategies of microrobotic carriers can be used in microvascular channels for the targeted delivery of drugs or cells in an organized manner.

5 March 2024 in Advanced Functional Materials
Verified
Journal Article
Open access
JYJonghwan Yoon
Jonghwan Yoon
YKYumin Kang
Yumin Kang
HKHyeonseol Kim
Hyeonseol Kim
AAAbbas Ali
Abbas Ali
KKKeonmok Kim
Keonmok Kim
CheolGi KimCheolGi Kim
CheolGi Kim
Conventional magnetophoresis techniques for manipulating biocarriers and cells predominantly rely on large‐scale electromagnetic systems, which is a major obstacle to the development of portable and miniaturized cell‐on‐chip platforms. Herein, a novel magnetic engineering approach by tailoring a nanoscale notch on a disk micromagnet using two‐step optical and thermal lithography is developed. Versatile manipulations are demonstrated, such as separation and trapping, of carriers and cells by mediating changes in the magnetic domain structure and discontinuous movement of magnetic energy wells around the circumferential edge of the micromagnet caused by a locally fabricated nano‐notch in a low magnetic field system. The motion of the magnetic energy well is regulated by the configuration of the nanoscale notch and the strength and frequency of the magnetic field, accompanying the jump motion of the carriers. The proposed concepts demonstrate that multiple carriers and cells can be manipulated and sorted using optimized nanoscale multi‐notch gates for a portable magnetophoretic system. This highlights the potential for developing cost‐effective point‐of‐care testing and lab‐on‐chip systems for various single‐cell‐level diagnoses and analyses.

15 December 2021 in Advanced Science
Verified
Journal Article
Open access
PDF file
JYJonghwan Yoon
Jonghwan Yoon
YKYumin Kang
Yumin Kang
HKHyeonseol Kim
Hyeonseol Kim
STSri Ramulu Torati
Sri Ramulu Torati
KKKeonmok Kim
Keonmok Kim
CheolGi KimCheolGi Kim
CheolGi Kim
Cell clustering techniques are important to produce artificial cell clusters for in vitro models of intercellular mechanisms at the single‐cell level. The analyses considering physical variables such as the shape and size of cells have been very limited. In addition, the precise manipulation of cells and control of the physical variables are still challenging. In this paper, a magnetophoretic device consisting of a trampoline micromagnet and active elements that enable the control of individual selective jumping motion and positioning of a micro‐object is proposed. Based on a numerical simulation under various conditions, automatic separation or selective clustering of micro‐objects according to their sizes is performed by parallel control and programmable manipulation. This method provides efficient control of the physical variables of cells and grouping of cells with the desired size and number, which can be a milestone for a better understanding of the intercellular dynamics between clustered cells at the single‐cell level for future cell‐on‐chip applications.

16 October 2023 in Small
Verified
Journal Article
Open access
AAAbbas Ali
Abbas Ali
HKHyeonseol Kim
Hyeonseol Kim
STSri Ramulu Torati
Sri Ramulu Torati
YKYumin Kang
Yumin Kang
VRVenu Reddy
Venu Reddy
CheolGi KimCheolGi Kim
CheolGi Kim
Functionalized microrobots, which are directionally manipulated in a controlled and precise manner for specific tasks, face challenges. However, magnetic field‐based controls constrain all microrobots to move in a coordinated manner, limiting their functions and independent behaviors. This article presents a design principle for achieving unidirectional microrobot transport using an asymmetric magnetic texture in the shape of a lateral ladder, which the authors call the “railway track.” An asymmetric magnetic energy distribution along the axis allows for the continuous movement of microrobots in a fixed direction regardless of the direction of the magnetic field rotation. The authors demonstrated precise control and simple utilization of this method. Specifically, by placing magnetic textures with different directionalities, an integrated cell/particle collector can collect microrobots distributed in a large area and move them along a complex trajectory to a predetermined location. The authors can leverage the versatile capabilities offered by this texture concept, including hierarchical isolation, switchable collection, programmable pairing, selective drug‐response test, and local fluid mixing for target objects. The results demonstrate the importance of microrobot directionality in achieving complex individual control. This novel concept represents significant advancement over conventional magnetic field‐based control technology and paves the way for further research in biofunctionalized microrobotics.

24 June 2022 in Materials Horizons
Verified
Journal Article
Closed access
PDF file
HKHyeonseol Kim
Hyeonseol Kim
YKYumin Kang
Yumin Kang
BLByeonghwa Lim
Byeonghwa Lim
KKKeonmok Kim
Keonmok Kim
JYJonghwan Yoon
Jonghwan Yoon
CheolGi KimCheolGi Kim
CheolGi Kim
We report the topographies created by 3D structures that change the intended control of magnetic colloids around a 2D micro-magnet. This device mimics natural systems such as electron orbitals, selective trapping and release of single-cell control.

23 February 1998 in SAE International Journal of Advances and Current Practices in Mobility
Verified
Conference Paper
Closed access
PDF file
SLSang Joon Lee
Sang Joon Lee
JYJong-Hwan Yoon
Jong-Hwan Yoon
KKKi-Won Kim
Ki-Won Kim
The temperature and velocity field variations of ventilation flow in the passenger compartment were measured simultaneously by using a digital image processing technique. A 1/10 scale vehicle was used for panel-vent mode heating. Micro-encapsulated TLC (Thermochromic Liquid Crystal) particles were used as a reliable tracer for temperature and velocity measurement. Particle color images captured with a 3 CCD (Charge Coupled Device) color video camera were used for calculating the velocity and temperature fields at the same time. To measure the temperature field variations, the HSI (Hue, Saturation, Intensity) true color image processing of TLC particles was applied to the TLC color images. A 2-frame particle tracking velocimetry using the concept of match probability between two consequent image frames was applied to the TLC particle displacements in order to measure the velocity field variations in the passenger compartment. The temperature and velocity fields measured simultaneously are well matched with each other and give reliable information on the ventilation flow.