Mohammad‐Reza Agha‐Kashkooli

Mohammad‐Reza Agha‐Kashkooli

Auto-generated profile, based on publicly available information

Mohammad‐Reza Agha‐Kashkooli

Northumbria University Newcastle,Faculty of Engineering and Environment,Newcastle upon Tyne,United Kingdom

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 March 2018 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
RSRamtin Sadeghi
Ramtin Sadeghi
SMSeyed M. Madani
Seyed M. Madani
MAM. Ataei
M. Ataei
MKM. R. Agha Kashkooli
M. R. Agha Kashkooli
SASul Ademi
Sul Ademi
This paper proposes and implements a super-twisting sliding mode direct power control (SSM-DPC) strategy for a brushless doubly fed induction generator (BDFIG). DPC has fast and robust response under transient conditions; however, it suffers from active and reactive power ripples and current distortions, which degrades the quality of the output power. In contrast, vector control has good steady-state current harmonic spectra; however, it is not robust to machine parameters variations, and thus needs a phase-locked loop for synchronous coordinate transformations. The SSM-DPC strategy controls active and reactive power directly without the need of the phase-locked loop. Moreover, its transient performance is similar to DPC and its steady-state performance is the same as vector control. The proposed controller is robust to uncertainties toward parameter variations and achieves constant converter switching frequency by using space vector modulation. Simulation and experimental results of a 2 MW and 3 kW laboratory-scale BDFIG are provided and compared with those of integral sliding mode and DPC to validate the effectiveness, correctness, and the robustness of the proposed strategy.

23 January 2019 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
MKM. R. Agha Kashkooli
M. R. Agha Kashkooli
SMSeyed M. Madani
Seyed M. Madani
TLThomas A. Lipo
Thomas A. Lipo
This paper proposes a new reference-generation-strategy for direct torque control (DTC) of doubly fed induction generator (DFIG), under symmetrical voltage-dips. Since DTC has no current-control loop, it cannot prevent overcurrent during voltage-dips. The proposed method prevents overcurrent in the rotor side converter (RSC), by damping the transient-flux and modifying the references of rotor-flux and torque, during voltage dip and recovery. The analysis of DTC for DFIG is presented by λ-i equivalent circuit which is decomposed into forced and natural circuits. Based on the natural λ-i circuit, the method adds a transient compensation term to the rotor-flux reference, which is obtained by multiplying the stator-natural-flux with a proposed decaying-ramp function. Moreover, this method reduces the forced component of rotor-flux proportional to the grid voltage. As a result, this method adjusts the transient-flux damping time and ensures overcurrent prevention in the rotor and stator windings. The torque reference is modified to maintain the torque-angle (between rotor and stator flux vectors) constant which results stable control of the DFIG during grid faults. The effectiveness of the proposed method is confirmed by experimental results of a 3-kW test set-up and simulation results of a 2-MW DFIG.

15 November 2018 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
RSRamtin Sadeghi
Ramtin Sadeghi
SMSeyed M. Madani
Seyed M. Madani
TLThomas A. Lipo
Thomas A. Lipo
MKM. R. Agha Kashkooli
M. R. Agha Kashkooli
MAMohammad Ataei
Mohammad Ataei
SASul Ademi
Sul Ademi
This paper presents the performance analysis of brushless doubly fed induction generator (BDFIG) during symmetrical voltage-dips. The equivalent-circuit consists of resistances and dependent voltage-sources in its rotor loop, thus its voltage-dip analysis becomes more challenging. To overcome such difficulty, a reduced full order model of the BDFIG into a new T-model is presented. A detailed mathematical analysis is performed subject to voltage-dip conditions. The time variation for the machines fluxes, EMFs, voltages, currents, active and reactive powers are analyzed and their analytical approach are derived. The current/voltage stress of power converter during voltage-dip is discussed. The accuracy of the proposed T-model and the theoretical voltage-dip is confirmed via experimental tests on a 3 kW BDFIG, and simulation results of a 2 MW BDFIG.

1 November 2021 in Renewable Energy
Verified
Journal Article
Closed access
MKM.R. Agha Kashkooli
M.R. Agha Kashkooli
MJMilutin G. Jovanović
Milutin G. Jovanović

7 June 2022 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
MAMohammadreza Aghakashkooli
Mohammadreza Aghakashkooli
MJMilutin Jovanovic
Milutin Jovanovic
A novel, cascaded model reference adaptive system (MRAS) observer design for speed and reactive power ( $\mathbf{Q}$ ) control of the emerging brushless doubly-fed reluctance generator (BDFRG) without a shaft position sensor, and no machine parameter knowledge, is proposed. The main advantages of the underlying estimation technique over the existing ones reported in the open literature are the intrinsic versatility, robustness, and accuracy, offering entirely decoupled torque (power) and $\mathbf{Q}$ responses. The reference model of the rotor angular velocity and position MRAS observer is purely based on the current measurements of the converter-fed (secondary) winding, and its adaptive counterpart on the measured grid voltages and currents at line frequency. The latter requires the inductance ratio for calculations, the online estimates of which being generated by the supplementary MRAS observer working in parallel. Doing so, a complete machine parameter independence and stability of the scheme have been achieved, and its viability fully experimentally validated under variable loading conditions of the small-scale BDFRG wind turbine emulated in a laboratory environment.

27 February 2018 in IET Electric Power Applications
Verified
Journal Article
Open access
PDF file
RSRamtin Sadeghi
Ramtin Sadeghi
SMSeyed M. Madani
Seyed M. Madani
MAMohammad‐Reza Agha‐Kashkooli
Mohammad‐Reza Agha‐Kashkooli
MAMohammad Ataei
Mohammad Ataei
Here, a reduced‐order model for stand‐alone cascaded doubly fed induction generator (CDFG) is presented for aircraft application, which is capable of operating in both starting and generating modes. This generator has lower maintenance cost and higher reliability, in comparison with traditional variable speed constant frequency system, based on a doubly fed induction generator (DFIG). These features make the CDFG appropriate for embedded aircraft applications. The main drawback of this generator is its inherent complexity; therefore, its analysis and control design is difficult. This complexity is due to the existence of resistances and voltage sources in the rotor loop of the full‐order model. To overcome this difficulty, this study proposes a reduced‐order model for the CDFG, which is similar to that of the DFIG in the synchronous reference frame. To demonstrate the efficiency of the proposed model, a field‐oriented controller for CDFG is designed based on this model and compared to the full‐order model. The performance and accuracy of the proposed model is validated through simulation and experimental results subject to balanced and unbalanced load change, and rotor speed variations test scenarios.