Derick N. Rosario-Berrios

Derick N. Rosario-Berrios

Auto-generated profile, based on publicly available information

Derick N. Rosario-Berrios

University of Pennsylvania

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 March 2025 in Nanoscale
Verified
Journal Article
Open access
PDF file
DRDerick N. Rosario-Berríos
Derick N. Rosario-Berríos
APAmanda Y. Pang
Amanda Y. Pang
KMKatherine J. Mossburg
Katherine J. Mossburg
JKJohoon Kim
Johoon Kim
VMVíctor R. Vázquez Marrero
Víctor R. Vázquez Marrero
DCDavid P. Cormode
David P. Cormode
Inflammatory bowel disease (IBD) affects approximately 3.1 million individuals in the U.S., causing deleterious symptoms such as bloody diarrhea and leading to an increased risk of colorectal cancer. Effective imaging is crucial for diagnosing and managing IBD, as it allows for accurate assessment of disease severity, guides treatment decisions, and monitors therapeutic responses. Computed tomography (CT) with contrast agents is the gold standard for imaging the gastrointestinal tract (GIT). However, current agents are less effective in obese patients and lack specificity for inflamed regions associated with IBD. Moreover, IBD treatments often have limited efficacy and do not address the role of oxidative stress in IBD progression. This study explores dextran-coated cerium oxide nanoparticles (Dex-CeNP) as a CT contrast agent and therapeutic for IBD, leveraging cerium's superior K-edge energy profile, dextran's inflammation-specific targeting, and cerium oxide's antioxidant properties. Herein, we synthesized Dex-CeNP formulations using 5, 10, 25, and 40 kDa dextran to explore the effect of dextran coating molecular weight. In vitro assays showed formulation biocompatibility and demonstrated that 5 kDa Dex-CeNP had the highest catalytic activity, which translated into improved suppression of inflammation. As a result, this formulation was selected for in vivo use. In vivo CT imaging of mice subjected to dextran sodium sulfate (DSS) colitis showed that Dex-CeNP provided better contrast in the GIT of mice with colitis compared to iopamidol (ISO), with pronounced attenuation in the large intestine and disease- specific retention at 24 h. Additionally, Dex-CeNP significantly decreased Disease Activity Index (DAI) scores, and diminished gastrointestinal bleeding when compared with a currently approved drug, indicating that it is an effective treatment for colitis. Studies also revealed that the Dex-CeNPs were safe and well-excreted following administration. In summary, Dex-CeNP has significant promise as a dual-purpose agent for CT imaging and treatment of IBD.

5 February 2024 in Physics in Medicine & Biology
Verified
Journal Article
Open access
LLLeening P Liu
Leening P Liu
RPRizza Pua
Rizza Pua
DRDerick N Rosario-Berrios
Derick N Rosario-Berrios
OSOlivia F Sandvold
Olivia F Sandvold
APAmy E Perkins
Amy E Perkins
PNPeter B Noël
Peter B Noël
Objectives . Evaluate the reproducibility, temperature tolerance, and radiation dose requirements of spectral CT thermometry in tissue-mimicking phantoms to establish its utility for non-invasive temperature monitoring of thermal ablations. Methods . Three liver mimicking phantoms embedded with temperature sensors were individually scanned with a dual-layer spectral CT at different radiation dose levels during heating (35 °C–80 °C). Physical density maps were reconstructed from spectral results using varying reconstruction parameters. Thermal volumetric expansion was then measured at each temperature sensor every 5 °C in order to establish a correlation between physical density and temperature. Linear regressions were applied based on thermal volumetric expansion for each phantom, and coefficient of variation for fit parameters was calculated to characterize reproducibility of spectral CT thermometry. Additionally, temperature tolerance was determined to evaluate effects of acquisition and reconstruction parameters. The resulting minimum radiation dose to meet the clinical temperature accuracy requirement was determined for each slice thickness with and without additional denoising. Results . Thermal volumetric expansion was robustly replicated in all three phantoms, with a correlation coefficient variation of only 0.43%. Similarly, the coefficient of variation for the slope and intercept were 9.6% and 0.08%, respectively, indicating reproducibility of the spectral CT thermometry. Temperature tolerance ranged from 2 °C to 23 °C, decreasing with increased radiation dose, slice thickness, and iterative reconstruction level. To meet the clinical requirement for temperature tolerance, the minimum required radiation dose ranged from 20, 30, and 57 mGy for slice thickness of 2, 3, and 5 mm, respectively, but was reduced to 2 mGy with additional denoising. Conclusions . Spectral CT thermometry demonstrated reproducibility across three liver-mimicking phantoms and illustrated the clinical requirement for temperature tolerance can be met for different slice thicknesses. The reproducibility and temperature accuracy of spectral CT thermometry enable its clinical application for non-invasive temperature monitoring of thermal ablation.

9 January 2025 in Bioconjugate Chemistry
Verified
Journal Article
Closed access
DRDerick N. Rosario-Berríos
Derick N. Rosario-Berríos
APAmanda Pang
Amanda Pang
LLLeening P. Liu
Leening P. Liu
PMPortia S. N. Maidment
Portia S. N. Maidment
JKJohoon Kim
Johoon Kim
DCDavid P. Cormode
David P. Cormode

5 October 2023 in medRxiv
Verified
Preprint
Open access
PDF file
LLLeening P. Liu
Leening P. Liu
RPRizza Pua
Rizza Pua
DRDerick N. Rosario-Berrios
Derick N. Rosario-Berrios
OSOlivia F. Sandvold
Olivia F. Sandvold
APAmy E. Perkins
Amy E. Perkins
PNPeter B. Noël
Peter B. Noël
Objectives: Evaluate the reproducibility, temperature sensitivity, and radiation dose requirements of spectral CT thermometry in tissue-mimicking phantoms to establish its utility for non-invasive temperature monitoring of thermal ablations. Materials and Methods: Three liver mimicking phantoms embedded with temperature sensors were individually scanned with a dual-layer spectral CT at different radiation dose levels during heating and cooling (35 to 80 °C). Physical density maps were reconstructed from spectral results using a range of reconstruction parameters. Thermal volumetric expansion was then measured at each temperature sensor every 5°C in order to establish a correlation between physical density and temperature. Linear regressions were applied based on thermal volumetric expansion for each phantom, and coefficient of variation for fit parameters was calculated to characterize reproducibility of spectral CT thermometry. Additionally, temperature sensitivity was determined to evaluate the effect of acquisition parameters, reconstruction parameters, and image denoising. The resulting minimum radiation dose to meet the clinical temperature sensitivity requirement was determined for each slice thickness, both with and without additional denoising. Results: Thermal volumetric expansion was robustly replicated in all three phantoms, with a correlation coefficient variation of only 0.43%. Similarly, the coefficient of variation for the slope and intercept were 9.6% and 0.08%, respectively, indicating reproducibility of the spectral CT thermometry. Temperature sensitivity ranged from 2 to 23 °C, decreasing with increased radiation dose, slice thickness, and iterative reconstruction level. To meet the clinical requirement for temperature sensitivity, the minimum required radiation dose ranged from 20, 30, and 57 mGy for slice thickness of 2, 3, and 5 mm, respectively, but was reduced to 2 mGy with additional denoising. Conclusions: Spectral CT thermometry demonstrated reproducibility across three liver-mimicking phantoms and illustrated the clinical requirement for temperature sensitivity can be met for different slice thicknesses. Moreover, additional denoising enables the use of more clinically relevant radiation doses, facilitating the clinical translation of spectral CT thermometry. The reproducibility and temperature accuracy of spectral CT thermometry enable its clinical application for non-invasive temperature monitoring of thermal ablation.

12 October 2026 in Physica Medica
Verified
Journal Article
Open access
AGAgnieszka J. Gutwinska
Agnieszka J. Gutwinska
DRDerick Rosario
Derick Rosario
ARAntoine Robert
Antoine Robert
ETEloise Thomas
Eloise Thomas
APAmanda Pang
Amanda Pang
SSSalim Aymeric Si-Mohamed
Salim Aymeric Si-Mohamed