Mark Carlson

Mark Carlson

Auto-generated profile, based on publicly available information

Mark Carlson

Micro-Tracers, Inc., San Francisco, CA 94124, USA

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 April 2026 in Poultry Science
Verified
Journal Article
Open access
SASeth Adesope
Seth Adesope
MCMark Carlson
Mark Carlson
NBNikolay Barashkov
Nikolay Barashkov
COCasey Owens
Casey Owens
TOTomi Obe
Tomi Obe
Given the increasing demand of poultry products, poultry processing continues to generate a large volume of wastewater rich in diverse foodborne pathogens that require effective treatment to support safe reuse. This study evaluated the disinfection rate of photo-electrochemical (PEC) treatment, which combines electrochemical (EC) and photochemical (PC) treatments for poultry processing wastewater. Wastewater from the scald and inside-outside bird washer (IOBW) units were treated using independent 7 L and 30 L PEC reactors operated at 70 V and 100 V EC with a fixed 1.6% curcumin for PC. Treatment was conducted for 300 minutes with aliquots collected every 30 minutes for quantification of aerobic bacteria (AC), Enterobacteriaceae (EB), coliforms (CC), and E. coli, on Petrifilm™. Furthermore, samples at 0, 150 and 300 minutes were selectively enriched and plated on Campylobacter agar and xylose lysine tergitol-4 for Campylobacter and Salmonella detection, respectively. Microbial reductions were reported as log10 CFU/mL and analyzed using linear mixed-effects model on R software (p ≤ 0.05) with a limit of detection of 1 CFU/mL. Across all wastewater types and reactor scales, PEC treatment at 70 V and 100 V achieved substantial reductions in AC, reducing initial loads of 5.4 - 6.2 log CFU/mL to 2.0 - 2.9 log CFU/mL within 300 minutes. Specifically, treatments at 100 V reduced AC to below the regulatory threshold of 500 CFU/mL (2.70 log CFU/mL) for wastewater reuse. EB, CC, and E. coli were completely inactivated, with faster disinfection generally observed at 100 V (120-180 minutes) compared to 70 V (180-210 minutes). Although differences between pathogen reductions were insignificant between 70 V and 100 V (p> 0.05), disinfection at 100 V showed a trend of quicker and greater microbial reduction across all microorganisms tested. Furthermore, Campylobacter and Salmonella were consistently eliminated within 150 minutes across all treatments. Overall, these findings demonstrate PEC as a viable, sustainable disinfection strategy which effectively reduced microorganisms including Campylobacter and Salmonella in processing wastewater, supporting safe reuse while reducing environmental impact.