Subin Kim

Subin Kim

Auto-generated profile, based on publicly available information

Subin Kim

Department of Otolaryngology-Head and Neck Surgery, Eunpyeong St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2018 in International Journal of Medical Sciences
Verified
Journal Article
Open access
HRHyewon Ryu
Hyewon Ryu
WLWonbong Lim
Wonbong Lim
DJDanbi Jo
Danbi Jo
SKSubin Kim
Subin Kim
JPJong-Tae Park
Jong-Tae Park
HKHyung-Seok Kim
Hyung-Seok Kim
Background: Evans blue dye (EBD) is the most common indicator to analyze the extent of blood-brain barrier (BBB) breakdown in several neurological disease models. However, the high-dose of EBD (51.9 mg/kg) is usually required for visualization of blue color by the human eye that brings potential safety issues.

28 February 2023 in Clinical and Experimental Otorhinolaryngology
Verified
Journal Article
Open access
PDF file
JKJi-Sun Kim
Ji-Sun Kim
SKSukil Kim
Sukil Kim
TMTae-Hoon Moon
Tae-Hoon Moon
SPSoomin Park
Soomin Park
SKSeung Hwa Kim
Seung Hwa Kim
JPJun-Ook Park
Jun-Ook Park
Objectives. Voice abuse in noisy environments can result in voice disorders. However, insufficient studies have sought to differentiate vocal cord lesions through laryngoscopic examinations among workers in noisy environments. This study investigated the relationship between a history of noise exposure in the workplace and benign vocal fold lesions (BVFLs).Methods. We used Korea National Health and Nutrition Examination Survey data from 2010 to 2012. The chi-square test was used to compare characteristics between two groups according to the presence or absence of BVFLs. To investigate the association between BVFLs and noise exposure in the workplace, we calculated adjusted odds ratios and 95% confidence intervals (CIs) using multiple logistic regression analysis.Results. In total, 10,170 participants with available laryngoscopy results were enrolled. Smoking history, hypertension, diabetes, and exposure to noise for more than 3 months at the workplace were significantly more common in participants with BVFLs. After adjusting for age, sex, smoking, drinking, obesity, hypertension, diabetes, income, education, and occupation as confounders, we confirmed that BVFLs were 1.52 times more likely (95% CI, 1.157–1.990) to occur in individuals with occupational noise exposure.Conclusion. Working in a noisy environment could induce BVFLs in workers through voice abuse. Social recognition that a noisy environment is a risk factor for BVFLs needs to be improved, and preventive measures should be implemented.

10 November 2022 in Journal of Korean Neurosurgical Society
Verified
Journal Article
Open access
PDF file
SKSubin Kim
Subin Kim
YLYun-Hee Lee
Yun-Hee Lee
SPSumin Park
Sumin Park
JJJunhui Jeong
Junhui Jeong
KCKi-Hong Chang
Ki-Hong Chang
Objective : This study aims to investigate the incidence of vestibular schwannoma (VS) and demographic characteristics in Korea using population-based National Health Insurance Service data.Methods : This study analyzed Korean National Health Insurance Service data from 2005 to 2020, based on the International Classification of Diseases, 10th version, Clinical Modification codes D333 and D431. Only those patients who had undergone magnetic resonance imaging and audiologic tests were considered definitive cases. Demographic variables included age, sex, treatment modality, hypertension, diabetics, dyslipidemia, smoking history, alcohol history, and income status.Results : The total number of VS patients was 5751. The average incidence rate was 0.71 per 100000 from 2005 to 2020, and the annual incidence rate increased from 0.33 in 2005 to 1.32 in 2019 but decreased to 0.80 in 2020. Incidence was highest in those aged 60–69 years (1.791) and lowest in those younger than 20 years (0.041). Incidence was higher in females, and the number of patients who received radiosurgery (46.64%) was largest compared to the wait and scan group (37.96%), microsurgery group (12.85%), or the group who received both (2.56%). Diabetes, dyslipidemia, and alcohol consumption increased the risk of VS, while cigarette smoking reduced the risk of VS.Conclusion : The incidence of VS exhibited an increasing trend from 2005 to 2019. Radiosurgery (46.64%) was the most common treatment modality. Diabetes, dyslipidemia, and alcohol consumption increased the risk of VS, while cigarette smoking reduced the risk of VS.

9 August 2023 in European Archives of Oto-Rhino-Laryngology
Verified
Journal Article
Closed access
PDF file
SKSubin Kim
Subin Kim
DMDa Hye Moon
Da Hye Moon
BJBeom-Cho Jun
Beom-Cho Jun
KPKyung-Ho Park
Kyung-Ho Park
KCKi-Hong Chang
Ki-Hong Chang

10 October 2021 in Journal of Audiology and Otology
Verified
Journal Article
Open access
PDF file
SKSubin Kim
Subin Kim
SYSunghwa You
Sunghwa You
MSMyoung Eun Sohn
Myoung Eun Sohn
WHWoojae Han
Woojae Han
JSJae-Hyun Seo
Jae-Hyun Seo
YOYonghee Oh
Yonghee Oh
Background and Objectives: The purpose of the present study was to validate the performance and diagnostic efficacy of the Korean digits-in-noise (K-DIN) test in comparison to the Korean speech perception-in-noise (K-SPIN) test, which is the representative speech-in-noise test in clinical practice.Subjects and Methods: Twenty-seven subjects (15 normal-hearing and 12 hearing-impaired listeners) participated. The recorded Korean 0-9 digits were used to form quasirandom digit triplets; 50 target digit triplets were presented at the most comfortable level of each subject while presenting speech-shaped background noise at various levels of signal-to-noise ratios (-12.5, -10, -5, or +5 dB). Subjects were then instructed to listen to both target and noise masker unilaterally and bilaterally through a headphone. K-SPIN test was also conducted using the same procedure as the K-DIN. After calculating their percent correct responses, K-DIN and K-SPIN results were compared using a Pearson-correlation test.Results: Results showed a statistically significant correlation between K-DIN and K-SPIN in all hearing conditions (left: r=0.814, p<0.001; right: r=0.788, p<0.001; bilateral: r=0.727, p<0.001). Moreover, the K-DIN test achieved better testing efficacy, shorter average listening time (5 min vs. 30 min), and easier performance of task according to participants’ qualitative reports than the K-SPIN test.Conclusions: In this study, the Korean version of digit triplet test was validated in both normal-hearing and hearing-impaired listeners. The findings suggest that the K-DIN test can be used as a simple and time-efficient hearing-in-noise test in audiology clinics in Korea.

10 April 2023 in Journal of Audiology and Otology
Verified
Journal Article
Open access
PDF file
SKSubin Kim
Subin Kim
CKChanbeom Kwak
Chanbeom Kwak
WHWoojae Han
Woojae Han
JSJae-Hyun Seo
Jae-Hyun Seo
YOYonghee Oh
Yonghee Oh
Background and Objectives: The digits-in-noise (DIN) test was developed as a simple and time-efficient hearing-in-noise test worldwide. The Korean version of the DIN (K-DIN) test was previously validated for both normal-hearing and hearing-impaired listeners. This study aimed to explore the factors influencing the outcomes of the K-DIN test further by analyzing the threshold (representing detection ability) and slope (representing test difficulty) parameters for the psychometric curve fit.Subjects and Methods: In total, 35 young adults with normal hearing participated in the K-DIN test under the following four experimental conditions: 1) background noise (digit-shaped vs. pink noise); 2) gender of the speaker (male vs. female); 3) ear side (right vs. left); and 4) digit presentation levels (55, 65, 75, and 85 dB). The digits were presented using the method of constant stimuli procedure. Participant responses to the stimulus trials were used to fit a psychometric function, and the threshold and slope parameters were estimated according to pre-determined criteria. The accuracy of fit performance was determined using the root-mean-square error calculation.Results: The listener’s digit detection ability (threshold) was slightly better with pink noise than with digit-shaped noise, with similar test difficulties (slopes) across the digits. Gender and the tested ear side influenced neither the detection ability nor the task difficulty. Additionally, lower presentation levels (55 and 65 dB) elicited better thresholds than the higher presentation levels (75 and 85 dB); however, the test difficulty varied slightly across the presentation levels.Conclusions: The K-DIN test can be influenced by stimulus factors. Continued research is warranted to understand the accuracy and reliability of the test better, especially for its use as a promising clinical measure.