27 December 2019 in Medical Engineering & Physics
Verified
Journal Article
Open access
MPMartin Preutenborbeck
Martin Preutenborbeck
JRJulian Reuter
Julian Reuter
EFElisabetta Ferrari
Elisabetta Ferrari
Total hip arthroplasty (THA) broaching involves impacting a broach handle with a mallet, facilitating force transmission to progress broaches into the femoral medullary canal. Limited surgical access during direct anterior THAs increases off-axis forces, potentially contributing to tissue damage. The aim was to characterise impactions during broaching. In a cadaver lab, movement of handle, femur and instrumented mallet was tracked during direct-anterior approach (DAA) and posterior approach (PA). Mallet velocity, broach displacement and input energy were calculated. Following the cadaver lab, different impaction strategies were investigated using bone simulants for a simulated DAA. The effects of reduced mallet velocity inputs and the influence of different impaction locations on the broach handle strike plate were investigated. To seat the broach in cadaveric bone, lower impaction energy (-59%) and number of strikes (-53%) were observed during PA compared to DAA. Suboptimal broach progression was reached in bone simulant at low mallet velocities (3.1 ± 0.3 m/s). Impacting the strike plate's upper part caused larger deflections (p < 0.001) of the Sawbones femur which suggested that higher off axis forces occurred. Awareness of reduced load transmission during DAA broaching using off-axis broach handles, compared to the traditional PA, could help promoting a more efficient and careful impaction strategy in surgeries.

6 October 2021 in Medical Engineering & Physics
Verified
Journal Article
Open access
NBN.E. Bishop
N.E. Bishop
PWP. Wright
P. Wright
CDC. Dudrey-Harvey
C. Dudrey-Harvey
MPM. Preutenborbeck
M. Preutenborbeck
Implants anchored by press-fit are predominantly implanted by impaction. This method allows sufficiently high forces to be generated easily by the surgeon. Suitable impaction should provide adequate implant seating without damaging the patient (tissues), the implant and implantation system, or the surgeon. However, issues have been documented for all of these factors. In this study a model to predict implant seating is developed, given an applied impaction impulse, the mass of the accelerated components and the push-in resistance force. The model was validated against experimental data for a contemporary femoral stem implanted in a polyurethane foam surrogate for bone, with the input parameters varied. The model tended to overestimate seating but represented seating patterns well. The model can be used to estimate implant seating using easily measured parameters and could be useful in the design of implantation systems, and in optimising impaction strategies.

11 April 2023 in Orthopaedic Proceedings
Verified
Journal Article
Closed access
MPM. Preutenborbeck
M. Preutenborbeck
PWP. Wright
P. Wright
GLG. Loughran
G. Loughran
NBN. Bishop
N. Bishop
PRE-CLINICAL TESTING AND FINITE ELEMENT SIMULATIONS OF ORTHOPAEDIC IMPACTION INSTRUMENTS USED IN SEATING OF IMPLANTS