Po-Chen Chen

Po-Chen Chen

Auto-generated profile, based on publicly available information

Po-Chen Chen

Texas A&M University, College Station, TX, USA

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 September 2012 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
PCPo-Chen Chen
Po-Chen Chen
RSReynaldo Salcedo
Reynaldo Salcedo
QZQingcheng Zhu
Qingcheng Zhu
FLFrancisco de Leon
Francisco de Leon
DCDariusz Czarkowski
Dariusz Czarkowski
RUResk Ebrahem Uosef
Resk Ebrahem Uosef
This paper presents a comprehensive analysis of the possible impacts of different penetration levels of distributed generation (DG) on voltage profiles in low-voltage secondary distribution networks. Detailed models of all system components are utilized in a study that performs hundreds of time-domain simulations of large networked distribution systems using the Electromagnetic Transients Program (EMTP). DGs are allocated in a probabilistic fashion to account for the uncertainties of future installations. The main contribution of this paper is the determination of the maximum amount of DG that secondary distribution networks can withstand without exhibiting undervoltage and overvoltage problems or unexpected load disconnections. This information is important for network planning engineers to facilitate the extension of the maximum penetration limit. The results show that depending on the location, type, and size of the installed DGs, small amounts of DG may cause overvoltage problems. However, large amounts of DG may not cause any voltage problems when properly selected.

12 April 2017 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
VMVuk Malbasa
Vuk Malbasa
CZCe Zheng
Ce Zheng
PCPo-Chen Chen
Po-Chen Chen
Tomo PopovicTomo Popovic
Tomo Popovic
MKMladen Kezunovic
Mladen Kezunovic
An active machine learning technique for monitoring the voltage stability in transmission systems is presented. It has been shown that machine learning algorithms may be used to supplement the traditional simulation approach, but they suffer from the difficulties of online machine learning model update and offline training data preparation. We propose an active learning solution to enhance existing machine learning applications by actively interacting with the online prediction and offline training process. The technique identifies operating points where machine learning predictions based on power system measurements contradict with actual system conditions. By creating the training set around the identified operating points, it is possible to improve the capability of machine learning tools to predict future power system states. The technique also accelerates the offline training process by reducing the amount of simulations on a detailed power system model around operating points where correct predictions are made. Experiments show a significant advantage in relation to the training time, prediction time, and number of measurements that need to be queried to achieve high prediction accuracy.

24 April 2019 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
JLJonatas Boas Leite
Jonatas Boas Leite
JMJose Roberto Sanches Mantovani
Jose Roberto Sanches Mantovani
TDTatjana Dokic
Tatjana Dokic
QYQin Yan
Qin Yan
PCPo-Chen Chen
Po-Chen Chen
MKMladen Kezunovic
Mladen Kezunovic
A new predictive risk-based framework is proposed to increase power distribution network resiliency by improving operator understanding of the status of the grid. This paper expresses the risk assessment as the correlation between likelihood and impact. The likelihood is derived from the combination of Naive Bayes learning and Jenks natural breaks classifier. The analytics included in a geographic information system platform fuse together a massive amount of data from outage recordings and weather historical databases in just one semantic parameter known as failure probability. The financial impact is determined by a time-series-based formulation that supports spatiotemporal data from fault management events and customer interruption cost. Results offer prediction of hourly risk levels and monthly accumulated risk for each feeder section of a distribution network allowing for timely tracking of the operating condition.

20 January 2015 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
PCPo-Chen Chen
Po-Chen Chen
VMVuk Malbasa
Vuk Malbasa
YDYimai Dong
Yimai Dong
MKMladen Kezunovic
Mladen Kezunovic
The presence of distributed generation (DG) in distribution networks may seriously affect accuracy of the voltage sag based fault location method. An approach toward quantifying the adverse effect of DG on the fault location calculation is described. A series of realistic scenarios is used to illustrate how DG impacts synchrophasor measurements during disturbances. Alternative Transients Program-Electromagnetic Transients Program models are used to obtain steady-state solutions in the time domain, while Sobol's approach to sensitivity analysis is used to quantify the effect of DG and imperfections of measuring instruments on fault location. Various test cases reveal that DG may adversely affect the voltage characteristic and therefore the accuracy of voltage sag based fault location.

6 June 2016 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
PCPo-Chen Chen
Po-Chen Chen
MKMladen Kezunovic
Mladen Kezunovic
Weather impacts are one of the main causes of distribution outages. To devise strategies to mitigate weather impacts, a fuzzy logic system for decision making is introduced. It allows utility operators to achieve more precise outage predictions and optimize real time operation and maintenance scheduling. A novel approach for weather-driven risk framework is applied to process the data and produce risk maps for better decision making. The use of weather data in reducing fault location time, an important performance improvement in outage management, is also presented.

1 October 2015
Verified
Conference Paper
Closed access
PCPo-Chen Chen
Po-Chen Chen
TDTatjana Dokic
Tatjana Dokic
NSNicholas Stokes
Nicholas Stokes
DGDaniel W. Goldberg
Daniel W. Goldberg
MKMladen Kezunovic
Mladen Kezunovic
Weather-related impacts are at the top of all outage causes. Yet, traditional outage management (OM) approaches do not integrate all available and relevant weather-associated data automatically. This paper presents a predictive method that correlates different weather-associated data layers to provide predictive OM process implemented using the geographic information systems (GIS) framework. Examples for both transmission and distribution OM are demonstrated using vegetation, wind, and power system data in ArcGIS.