Bernhard L. Gerber

Bernhard L. Gerber

Auto-generated profile, based on publicly available information

Bernhard L. Gerber

Division of Cardiology, Cardiovascular Department, Cliniques Universitaires Saint-Luc and Institut de Recherche Experimentale et Clinique (IRECT), UCLouvain, Brussels, Belgium

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 March 2019 in European Heart Journal - Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
MAM S Amzulescu
M S Amzulescu
MCM De Craene
M De Craene
HLH Langet
H Langet
APA Pasquet
A Pasquet
DVD Vancraeynest
D Vancraeynest
BGB L Gerber
B L Gerber
Myocardial tissue tracking imaging techniques have been developed for a more accurate evaluation of myocardial deformation (i.e. strain), with the potential to overcome the limitations of ejection fraction (EF) and to contribute, incremental to EF, to the diagnosis and prognosis in cardiac diseases. While most of the deformation imaging techniques are based on the similar principles of detecting and tracking specific patterns within an image, there are intra- and inter-imaging modality inconsistencies limiting the wide clinical applicability of strain. In this review, we aimed to describe the particularities of the echocardiographic and cardiac magnetic resonance deformation techniques, in order to understand the discrepancies in strain measurement, focusing on the potential sources of variation: related to the software used to analyse the data, to the different physics of image acquisition and the different principles of 2D vs. 3D approaches. As strain measurements are not interchangeable, it is highly desirable to work with validated strain assessment tools, in order to derive information from evidence-based data. There is, however, a lack of solid validation of the current tissue tracking techniques, as only a few of the commercial deformation imaging softwares have been properly investigated. We have, therefore, addressed in this review the neglected issue of suboptimal validation of tissue tracking techniques, in order to advocate for this matter.

1 December 2004 in JACC
Verified
Journal Article
Closed access
LALuciano C. Amado
Luciano C. Amado
BGBernhard L. Gerber
Bernhard L. Gerber
SGSandeep N. Gupta
Sandeep N. Gupta
DRDan W. Rettmann
Dan W. Rettmann
GSGilberto Szarf
Gilberto Szarf
JLJoão A.C. Lima
João A.C. Lima

2 July 2002 in Circulation
Verified
Journal Article
Closed access
TEThor Edvardsen
Thor Edvardsen
BGBernhard L. Gerber
Bernhard L. Gerber
JGJérÔmE Garot
JérÔmE Garot
DBDavid A. Bluemke
David A. Bluemke
JLJoão A.C. Lima
João A.C. Lima
OSOtto A. Smiseth
Otto A. Smiseth
Background — Tissue Doppler echocardiography–derived strain rate and strain measurements (SDE) are new quantitative indices of intrinsic cardiac deformation. The aim of this study was to validate and compare these new indices of regional cardiac function to measurements of 3-dimensional myocardial strain by tagged MRI. Methods and Results — The study population included 33 healthy volunteers, 17 patients with acute myocardial infarction, and 8 patients with suspected coronary artery disease who were studied during dobutamine stress echocardiography. Peak systolic myocardial velocities were measured by tissue Doppler echocardiography, peak systolic strain rates and strains by SDE, and strains by tagged MRI. In healthy individuals, longitudinal myocardial Doppler velocities decreased progressively from base to apex, whereas myocardial strain rates and strains were uniform in all segments. In patients with acute infarction, abnormal strains clearly identified dysfunctional areas. In infarcted regions, SDE showed 1.5±4.3% longitudinal stretching compared with −15.0±3.9% shortening in remote myocardium ( P <0.001), and radial measurements showed −6.9±4.1% thinning and 14.3±5.0% thickening ( P <0.001), respectively. During dobutamine infusion, longitudinal strains by SDE increased significantly from −13.5% to −23.8% ( P <0.01) and radial strains increased from 13.1±3.1% to 29.3±11.5% ( P <0.01). Comparisons between myocardial strains by SDE and tagged MRI in healthy individuals (n=11), in infarct patients (n=17), and during stress echo (n=4) showed excellent correlations ( r =0.89 and r =0.96 for longitudinal and radial strains, respectively, P < 0.001). Conclusions — The present study demonstrates the ability of Doppler echocardiography to measure myocardial strains in a clinical setting. Myocardial strains by Doppler may represent a new powerful method for quantifying left ventricular function noninvasively in humans.

14 February 2006 in Circulation
Verified
Journal Article
Closed access
BGBernhard L. Gerber
Bernhard L. Gerber
BBBénÉdIcte Belge
BénÉdIcte Belge
GLGabin J. Legros
Gabin J. Legros
PLPascal Lim
Pascal Lim
APAlain Poncelet
Alain Poncelet
JVJean-Louis J. Vanoverschelde
Jean-Louis J. Vanoverschelde
Background— We evaluated whether contrast-enhanced multidetector computed tomography (CE-MDCT) might characterize myocardial infarct (MI) with patterns similar to those obtained by contrast-enhanced magnetic resonance (CE-MR) and studied the underlying mechanisms. Methods and Results— In vivo infarct characterization by CE-MDCT was shown to be feasible between 4 and 20 minutes after contrast injection in 7 pigs with MI. Subsequently, in 16 patients with acute MI and 21 patients with chronic MI, contrast patterns by CE-MDCT were related to CE-MR. Eighteen patients had hypoenhanced regions on early CE-MDCT images at the time of coronary imaging, and 34 patients had hyperenhanced regions on images acquired 10 minutes later. On a segmental basis, there was moderately good concordance of early hypoenhanced regions (92%, κ=0.54, P <0.001) and late hyperenhanced regions (82%, κ=0.61, P <0.001) between CE-MDCT and CE-MR. Absolute sizes of early hypoenhanced (6±16 versus 7±16 g, P =0.25) and late hyperenhanced (36±34 versus 31±40 g, P =0.14) regions were similar on CE-MDCT and CE-MR and were highly correlated ( r =0.93, P <0.001 and r =0.89, P <0.001 respectively). In 8 retrogradely perfused infarcted rabbit hearts, contrast kinetics of iomeprol were similar to gadodiamide, ie, slow wash in (8.7±6.7 versus 1.2±0.3 minutes, P <0.001) in infarct core and slow washout (20±12 versus 2.5±0.5 minutes, P <0.001) in both infarct core and rim compared with the remote region. Conclusions— Because iodated contrast agents have similar kinetics in infarcted and noninfarcted myocardium as gadolinium DPTA, CE-MDCT can characterize acute and chronic MI with contrast patterns similar to CE-MR. CE-MDCT may thus provide important information on infarct size and viability at the time of noninvasive coronary imaging.

27 August 2002 in Circulation
Verified
Journal Article
Closed access
BGBernhard L. Gerber
Bernhard L. Gerber
JGJérÔmE Garot
JérÔmE Garot
DBDavid A. Bluemke
David A. Bluemke
KWKathérIne C. Wu
KathérIne C. Wu
JLJoao A. C. Lima
Joao A. C. Lima
Background— Contrast-enhanced (CE) MRI demonstrates a pattern of hypoenhancement early after contrast injection in acute myocardial infarction (MI) and a pattern of hyperenhancement late after contrast injection. Because the significance of these CE patterns for myocardial viability remains debated, we evaluated their diagnostic accuracy to quantitatively predict late functional improvement of regional contractility. Methods and Results— Twenty patients underwent CE and tagged MRI at 4 days and again at 7 months after acute MI. Resting circumferential shortening strain (Ecc) was analyzed in 24 segments per patient, and its improvement was correlated with the presence or absence of the CE patterns. Immediately after MI, 389 segments were considered dysfunctional because of having less than mean±2 SD Ecc of the remote region (−18±4%). At follow-up, significant improvement of Ecc occurred in 170 dysfunctional segments with normal CE (from −4±7% to −12±7%, P <0.001) but not in 60 segments with early hypoenhancement (from −2±6% to −6±9% Ecc, P =NS). In 240 dysfunctional segments with delayed hyperenhancement, the improvement of Ecc (from −2±6% to −5±8%, P <0.001) decreased with increasing transmural extent of hyperenhancement. Receiver operating characteristic analysis demonstrated that absence of delayed hyperenhancement, compared with absence of early hypoenhancement, had better sensitivity (82% versus 19%, respectively; P <0.001) and accuracy (74% versus 49%, respectively; P <0.001) in predicting recovery of Ecc to any given level. Conclusions— Compared with lack of early hypoenhancement, lack of delayed hyperenhancement has better diagnostic accuracy in predicting functional improvement in dysfunctional segments. The early hypoenhanced regions, which represent only the fraction of infarcted tissue with concomitant microvascular obstruction, greatly underestimate the amount of irreversibly injured myocardium present after acute MI.

1 July 2014 in JACC
Verified
Journal Article
Closed access
GBGilles Barone-Rochette
Gilles Barone-Rochette
SPSophie Piérard
Sophie Piérard
CRChristophe De Meester de Ravenstein
Christophe De Meester de Ravenstein
SSStéphanie Seldrum
Stéphanie Seldrum
JMJulie Melchior
Julie Melchior
BGBernhard L. Gerber
Bernhard L. Gerber