18 July 2018 in IEEE Transactions on Transportation Electrification
A power-hardware-in-the-loop (PHIL) based machine emulator system, which is essentially power converters controlled to mimic machine behavior, can be used to test the traction drive inverter and drive controller prior to the development of an electric motor prototype. In this paper, a PHIL based machine emulation system, which uses machine models based on look-up table data, generated from finite element analysis tools, is proposed. Using such machine models allows for the emulation of the machine’s magnetic (eg. saturation) and geometric (eg. cogging-torque) characteristics, greatly improving the emulation accuracy and utility. The proposed machine emulator system uses an inductive filter to interface the emulator and the driving inverter, and a current control for the machine emulator. This allows for a simple practical realization of the machine emulator system. A detailed analysis of the machine emulator control to accurately emulate the machine model behavior is also presented here followed by real-time simulation results validating the same. Experimental results are then obtained from the proposed emulator system and from a surface-mounted permanent magnet synchronous motor coupled to a DC dynamometer. These results are compared for various transient conditions such as machine start-up, speed reversal, and load change to validate the emulation accuracy.
5 June 2019 in IEEE Transactions on Industry Applications
Emulation of an electric machine allows the testing of a drive inverter and controller of an electric drive system, prior to the manufacture of a machine prototype. This paper presents the emulation of a variable flux machine (VFM). The VFM emulator system proposed in this paper uses a detailed look-up table based machine model for the purpose of emulation. This allows the emulator to mimic all machine magnetic and geometric behaviors such as saturation and torque ripple. In addition, the machine emulator proposed in this paper uses high-performance high-bandwidth linear amplifiers as power amplifiers. This enables a high bandwidth; leading to a high accuracy machine emulation. A detailed control description for the proposed machine emulator system and a machine model look-up table data verification against a prototype machine is initially presented. Experimental results are then presented to validate the utility of the proposed VFM emulator system to emulate various machine transient behaviors at different magnetization levels. Experimental results obtained from the emulator are subsequently compared against the experimental results obtained from a prototype VFM drive to verify the emulation accuracy.
28 November 2017 in IEEE Transactions on Transportation Electrification
Permanent-magnet synchronous generators (PMSGs) are used in several applications of traction electrification such as power supplies for auxiliary systems and vehicle on-board range-extenders. In this paper, a PMSG is emulated using power hardware in-the-loop. This emulation scheme provides a method to eliminate risks and costs associated with the testing, prototyping, and validation of controllers for power converters and other parts of the traction system. The proposed scheme can be used for testing of motor drives' different parameters, thereby enabling the testing of a variety of electrical machine drives where the machine prototype is unavailable. The voltage output of the proposed emulator system replicates the voltage generated within the real-time model. The terminal voltage from the real-time model depends on the load connected to the emulator terminals; the current drawn from the emulator output terminals is sensed and fed back to enable the emulator to replicate the PMSG characteristics in steady state and transients. The performance of the system for nonlinear loads, such as a rectifier with a capacitor filter and transient conditions, is also experimentally verified and presented along with validation against a physical PMSG coupled to a dynamometer.
9 April 2018 in IEEE Transactions on Transportation Electrification
Different electric machines are considered for electrified transportation systems. A failure in the control algorithm can result in damage to both the drive and the connected machine. In this paper, an induction motor emulator based on a power electronic converter is developed to allow detailed testing the converter and controller. A proportional-resonant current controller in the abc-frame and pulsewidth modulation is employed. The conventional model of the induction machine with constant parameters does not represent accurately the machine's performance for severe transients specifically during starting and loading conditions. Magnetic saturation effects should be considered. Hence, experimental procedures to determine the flux saturation characteristics in the main and both stator and rotor leakage flux paths are achieved. An approach that utilizes finite-element modeling to separate the leakage reactance at rated current and when the machine is deeply saturated is discussed and verified experimentally. Machine models that consider or neglect the main and leakage flux saturation are compared with experimental results. The model, which considers the magnetic saturation effect in both flux paths, results in more accurate transient responses. Likewise, the dynamic response of the induction motor emulator during startup and loading transients shows the effectiveness of using the developed emulator to resemble closely a real motor.
2 July 2020 in IEEE Transactions on Transportation Electrification
Power Hardware-in-the-loop (PHIL) simulations, in the form of machine emulation, are gaining popularity for electric drive system testing in transportation applications. Since there is a reduced chance of equipment damage with PHIL simulations, they are particularly suited for the testing of electric drive systems, for drive inverter faults. This paper investigates PHIL simulations to emulate machine behavior in the event of drive inverter faults resulting due to a gate-drive failure of one or more switches. Modifications are proposed to the closed loop current control of the machine emulator system. These modifications ensure that various lower order harmonics in the emulated machine currents, resulting due to the drive inverter faults, are accurately emulated. Drive inverter damage resulting due to machine behavior emulation in fault conditions, are avoided by proposing appropriate emulator control structure modifications. Experimental results are obtained for the emulation of machine behavior for various drive inverter gate-drive faults. These experimental results are compared with that obtained from a faulty drive inverter feeding a prototype machine. A close match between the two results is shown to prove the sufficiency and utility of the proposed controller modifications in the developed PHIL based machine emulation system.