1 July 2024 in Review of Scientific Instruments
Microwave reflectometry is an invaluable diagnostic tool for measuring electron density profiles in large fusion devices. Density fluctuations near the plasma cutoff layer, particularly those that are time-varying on the timescale of the reflectometry measurement, can result in distortions in phase and/or amplitude of the reflected waveform, which present challenges to the accuracy of the reconstructed profile. The ultra-short pulse reflectometry (USPR) technique eliminates the time-varying issue in that reflectometry data are collected on a nanosecond timescale, essentially freezing the fluctuations in place. An X-mode dedicated 32-channel USPR system has been developed and installed on the EAST, covering the operation frequency range from 52 to 92 GHz. This system enables high-resolution density profile measurements in the plasma pedestal and scrape-off layer, with resolutions reaching 5 mm and 1 μs, respectively. Laboratory testing of the system performance has been conducted, demonstrating the potential of the USPR technique to provide accurate and high-temporal-resolution density profiles in challenging plasma environments.
1 February 2024 in Review of Scientific Instruments
A carefully designed waveguide-based millimeter-wave notch filter, operating at 140 GHz, safeguards plasma diagnostic instruments from gyrotron leakage. Utilizing cylindrical cavity resonators with aperture coupling, the filter efficiently resonates 140 GHz wave-power into the TE11p mode, optimizing various geometrical parameters for practical fabrication and high-yield production. Thorough thermal analysis ensures its ability to handle power. The filter achieves outstanding performance with over 90 dB rejection at 140 GHz while providing low insertion loss over the passband (110–138 GHz), which is ideally suited for system-on-chip approach F-band diagnostic system applications.
1 July 2024 in Review of Scientific Instruments
An Electron Cyclotron Emission (ECE) modeling code has been developed to model ECE radiation with an arbitrary electron momentum distribution, a small oblique angle, both ordinary (O-mode) and extraordinary polarizations (X-mode), and multiple cyclotron frequency harmonics. The emission and absorption coefficients are calculated using the Poynting theorem from the cold plasma dispersion and the electron–microwave interaction from the full anti-Hermitian tensor. The modeling shows several ECE radiation signatures that can be used to diagnose the population of suprathermal electrons in a tokamak. First, in an n = 2 X-mode (X2) optically thick plasma and oblique ECE view, the modeling shows that only suprathermal electrons, which reside in a finite region of the velocity and space domains, can effectively generate cyclotron emissions to the ECE receiver. The code also finds that the O1 mode is sensitive to suprathermal electrons of both a high v⊥ and v‖, while the X2 mode is dominantly sensitive to suprathermal electrons of a high v⊥. The modeling shows that an oblique ECE system with both X/O polarization and a broad frequency coverage can be used to effectively yield information of the suprathermal electron population in a tokamak.
1 October 2024 in Journal of Instrumentation
The notch filter plays a crucial role as a protective component in microwave diagnostics, primarily by addressing issues related to catastrophic interference. Designed for millimeter-wave diagnostics on the stellarator Wendelstein 7-X (W7-X), a WR-6 waveguide-based notch filter has been successfully developed to effectively isolate leakage from auxiliary heating gyrotrons operating at 140 GHz. The filter incorporates cylindrical cavities resonating at 140 GHz for the TE11p mode, with coupling structures that are designed and optimized for high-efficiency coupling. This configuration simplifies fabrication, thereby ensuring high-yield production. Experimental fabrication and in-house characterization confirm the notch filter's exceptional performance, with over 60 dB rejection in the vicinity of 140 GHz and low insertion loss (< 2 dB) above and below the notch frequency across a broad frequency bandwidth (121–138 GHz, 142–163 GHz). The utilization of this high-frequency structure fabrication technology can be applied to millimeter-wave diagnostics on other machines. In addition to the design elements of the notch filter, this paper also provides a detailed discussion of the fabrication process and methodology.
4 March 2025 in Fusion Engineering and Design
1 October 2026 in Nature Communications
Pulse Electron Paramagnetic Resonance (EPR) spectroscopy provides powerful tools for examining species with unpaired electrons, such as organic radicals and metal ions, in a wide variety of interesting systems. However, the lack of high power pulse amplifiers above approximately 100 GHz has limited its applicability at very high frequencies and magnetic fields. Here we describe the use of a new 10 W high frequency traveling wave vacuum tube amplifier employed in a pulse EPR spectrometer operating over a wide frequency bandwidth centered at 263 GHz. Very high frequency pulse EPR is of particular utility for studying spin S > 1/2 species, given that large broadening effects of “zero-field splitting” interactions often dominate EPR spectra obtained at low frequency. Improvements obtained at 263 GHz are illustrated for a series of high spin (S=5/2) Mn(II) complexes starting with Mn(II) impurities in a diamagnetic host up though Mn(II) bound in metal sequestering proteins. The instrument has sufficient mm-wave power to obtain high signal-to-noise electron spin echoes without a resonator, which offers a number of advantages as described herein.