Koen P. A. Baas

Koen P. A. Baas

Auto-generated profile, based on publicly available information

Koen P. A. Baas

From the Department of Radiology and Nuclear Medicine (K.P.A.B., A.J.N.), Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, the Netherlands

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 November 2020 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
KBK.P.A. Baas
K.P.A. Baas
JPJ. Petr
J. Petr
JKJ.P.A. Kuijer
J.P.A. Kuijer
ANA.J. Nederveen
A.J. Nederveen
HMHenk Mutsaerts
Henk Mutsaerts
KVK.C.C. van de Ven
K.C.C. van de Ven
BACKGROUND AND PURPOSE: Although the added diagnostic value of arterial spin-labeling is shown in various cerebral pathologies, its use in clinical practice is limited. To encourage clinical adoption of ASL, we investigated the reproducibility of CBF measurements and the effects of variations in acquisition parameters compared to the recommended ASL implementation. MATERIALS AND METHODS: Thirty-four volunteers (mean age, 57.8 ± 17.0 years; range, 22–80 years) underwent two separate sessions (1.5T and 3T scanners from a single vendor) using a 15-channel head coil. Both sessions contained repeated 3D and 2D pseudocontinuous arterial spin-labeling scans using vendor-recommended acquisition parameters (recommendation paper–based), followed by three 3D pseudocontinuous arterial spin-labeling scans, two with postlabeling delays of 1600 and 2000 ms and one with increased spatial resolution. All scans were single postlabeling delay. Intrasession (identical acquisitions, scanned five minutes apart) and intersession (first 2D and 3D acquisitions of two sessions) reproducibility was examined as well as the effect of parameter variations on CBF. RESULTS: Intrasession CBF reproducibility was similar across image readouts and field strengths (within-subject coefficient of variation between 4.0% and 6.7%). Intersession within-subject coefficient of variation ranged from 6.6% to 14.8%. At 3T, the 3D acquisition with a higher spatial resolution resulted in less mixing of GM and WM signal, thus decreasing the bias in GM CBF between the 2D and 3D acquisitions (ΔCBF = 2.49 mL/100g/min [P < .001]). Postlabeling delay variations caused a modest bias (ΔCBF between −3.78 [P < .001] and 2.83 [P < .001] mL/100g/min). CONCLUSIONS: Arterial spin-labeling imaging is reproducible at both field strengths, and the reproducibility is not significantly correlated with age. Furthermore, 3T tolerates more acquisition parameter variations and allows more extensive optimizations so that 3D and 2D acquisitions can be compared.

28 September 2023 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
KBKoen P.A. Baas
Koen P.A. Baas
AEAlbert J. Everard
Albert J. Everard
SKSimon Körver
Simon Körver
LDLaura van Dussen
Laura van Dussen
BCBram Coolen
Bram Coolen
ANAart J. Nederveen
Aart J. Nederveen
BACKGROUND AND PURPOSE: White matter lesions are commonly found in patients with Fabry disease. Existing studies have shown elevated diffusivity in healthy-appearing brain regions that are commonly associated with white matter lesions, suggesting that DWI could help detect white matter lesions at an earlier stage This study explores whether diffusivity changes precede white matter lesion formation in a cohort of patients with Fabry disease undergoing yearly MR imaging examinations during a 5-year period. MATERIALS AND METHODS: T1-weighted anatomic, FLAIR, and DWI scans of 48 patients with Fabry disease (23 women; median age, 44 years; range, 15–69 years) were retrospectively included. White matter lesions and tissue probability maps were segmented and, together with ADC maps, were transformed into standard space. ADC values were determined within lesions before and after detection on FLAIR images and compared with normal-appearing white matter ADC. By means of linear mixed-effects modeling, changes in ADC and ΔADC (relative to normal-appearing white matter) across time were investigated. RESULTS: ADC was significantly higher within white matter lesions compared with normal-appearing white matter (P < .01), even before detection on FLAIR images. ADC and ΔADC were significantly affected by sex, showing higher values in men (60.1 [95% CI, 23.8–96.3] ×10–6mm2/s and 35.1 [95% CI, 6.0–64.2] ×10–6mm2/s), respectively. ΔADC increased faster in men compared with women (0.99 [95% CI, 0.27–1.71] ×10–6mm2/s/month). ΔADC increased with time even when only considering data from before detection (0.57 [95% CI, 0.01–1.14] ×10–6mm2/s/month). CONCLUSIONS: Our results indicate that in Fabry disease, changes in diffusion precede the formation of white matter lesions and that microstructural changes progress faster in men compared with women. These findings suggest that DWI may be of predictive value for white matter lesion formation in Fabry disease.

25 January 2022 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Closed access
PDF file
KBKoen P. A. Baas
Koen P. A. Baas
BCBram Coolen
Bram Coolen
EPEsben T. Petersen
Esben T. Petersen
BBBart J. Biemond
Bart J. Biemond
GSGustav Strijkers
Gustav Strijkers
ANAart J. Nederveen
Aart J. Nederveen

24 April 2023 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
KBKoen P. A. Baas
Koen P. A. Baas
CVChau Vu
Chau Vu
JSJian Shen
Jian Shen
BCBram Coolen
Bram Coolen
BBBart J. Biemond
Bart J. Biemond
ANAart J. Nederveen
Aart J. Nederveen
Background: Oxygen extraction fraction (OEF) and cerebral metabolic rate of oxygen (CMRO2) may serve as biomarkers in several diseases. OEF and CMRO2 can be estimated from venous blood oxygenation (Yv) levels, which in turn can be calculated from venous blood T2 values (T2b). T2b can be measured using different MRI sequences, including T2‐relaxation‐under‐spin‐tagging (TRUST) and T2‐prepared‐blood‐relaxation‐imaging‐with‐inversion‐recovery (T2‐TRIR). The latter measures both T2b and T1 (T1b) but was found previously to overestimate T2b compared to TRUST. It remained unclear, however, if this bias is constant across higher and lower oxygen saturations.Purpose: To compare TRUST and T2‐TRIR across a range of O2 saturations using hypoxic and hypercapnic gas challenges.Study Type: Prospective.Population: Twelve healthy volunteers (four female, age 36 ± 10 years).Field Strength/Sequence: A 3T; turbo‐field echo‐planar‐imaging (TFEPI), echo‐planar‐imaging (EPI), and fast‐field‐echo (FFE).Assessment: TRUST‐ and T2‐TRIR‐derived T2b, Yv, OEF, and CMRO2 were compared across different respiratory challenges. T1b from T2‐TRIR was used to estimate Hct (HctTRIR) and compared with venipuncture (HctVP).Statistical Tests: Shapiro–Wilk, one‐sample and paired‐sample t‐test, repeated measures ANOVA, Friedman test, Bland–Altman, and correlation analysis. Bonferroni multiple‐comparison correction was performed. Significance level was 0.05.Results: A significant bias was observed between TRUST‐ and T2‐TRIR‐derived T2b, Yv, and OEF values (−13 ± 11 msec, −5.3% ± 3.5% and 5.9 ± 4.1%, respectively). For Yv and OEF, this bias was constant across the range of measured values. T1b was significantly lower during severe hypoxia and hypercapnia compared to baseline (1712 ± 86 msec and 1634 ± 79 msec compared to 1757 ± 90 msec). While no significant bias was found between HctVP and HctTRIR (0.02% ± 0.06%, P = 0.20), the correlation between these Hct values was significant but weak (r = 0.19).Data Conclusion: Given the constant bias, TRUST‐ and T2‐TRIR‐derived venous T2b values can be used interchangeably to estimate Yv, OEF, and CMRO2 across a broad range of oxygen saturations. Hct from T2‐TRIR‐derived T1‐values only weakly correlated with Hct from venipuncture.Evidence Level: 2Technical Efficacy: Stage 2.