Armand Béché

Armand Béché

Auto-generated profile, based on publicly available information

Armand Béché

EMAT, University of Antwerp, Antwerp, Belgium

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 December 2014 in Nature Communications
Verified
Journal Article
Open access
KMKnut Müller
Knut Müller
FKFlorian F. Krause
Florian F. Krause
ABArmand Béché
Armand Béché
MSMarco Schowalter
Marco Schowalter
VGVincent Galioit
Vincent Galioit
ARAndreas Rosenauer
Andreas Rosenauer
By focusing electrons on probes with a diameter of 50 pm, aberration-corrected scanning transmission electron microscopy (STEM) is currently crossing the border to probing subatomic details. A major challenge is the measurement of atomic electric fields using differential phase contrast (DPC) microscopy, traditionally exploiting the concept of a field-induced shift of diffraction patterns. Here we present a simplified quantum theoretical interpretation of DPC. This enables us to calculate the momentum transferred to the STEM probe from diffracted intensities recorded on a pixel array instead of conventional segmented bright-field detectors. The methodical development yielding atomic electric field, charge and electron density is performed using simulations for binary GaN as an ideal model system. We then present a detailed experimental study of SrTiO3 yielding atomic electric fields, validated by comprehensive simulations. With this interpretation and upgraded instrumentation, STEM is capable of quantifying atomic electric fields and high-contrast imaging of light atoms.

1 December 2013 in Nature Physics
Verified
Journal Article
Open access
PDF file
ABArmand Béché
Armand Béché
RBRuben Van Boxem
Ruben Van Boxem
GTGustaaf Van Tendeloo
Gustaaf Van Tendeloo
JVJo Verbeeck
Jo Verbeeck
Magnetic monopoles continue to be elusive. However, an experiment now shows that the interaction of an electron beam with the tip of a nanoscopically thin magnetic needle—a close approximation to a magnetic monopole field—generates an electron vortex state, as expected for a true magnetic monopole field. The experimental search for magnetic monopole particles1,2,3 has, so far, been in vain. Nevertheless, these elusive particles of magnetic charge have fuelled a rich field of theoretical study4,5,6,7,8,9,10. Here, we created an approximation of a magnetic monopole in free space at the end of a long, nanoscopically thin magnetic needle11. We experimentally demonstrate that the interaction of this approximate magnetic monopole field with a beam of electrons produces an electron vortex state, as theoretically predicted for a true magnetic monopole3,11,12,13,14,15,16,17,18. This fundamental quantum mechanical scattering experiment is independent of the speed of the electrons and has consequences for all situations where electrons meet such monopole magnetic fields, as, for example, in solids. The set-up not only shows an attractive way to produce electron vortex states but also provides a unique insight into monopole fields and shows that electron vortices might well occur in unexplored solid-state physics situations.

17 November 2022 in Nature Catalysis
Verified
Journal Article
Closed access
PDF file
APAlexander Parastaev
Alexander Parastaev
VMValery Muravev
Valery Muravev
EOElisabet Huertas Osta
Elisabet Huertas Osta
TKTobias F. Kimpel
Tobias F. Kimpel
JSJérôme F. M. Simons
Jérôme F. M. Simons
EHEmiel J.M Hensen
Emiel J.M Hensen

21 September 2009 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
ABA. Béché
A. Béché
JRJ. L. Rouvière
J. L. Rouvière
LCL. Clément
L. Clément
JHJ. M. Hartmann
J. M. Hartmann
Improvements in transmission electron microscopy have transformed nanobeam electron diffraction into a simple and powerful technique to measure strain. A Si0.69Ge0.31 layer, grown onto a Si substrate has been used to evaluate the precision and accuracy of the technique. Diffraction patterns have been acquired along a ⟨110⟩ zone axis using a FEI-Titan microscope and have been analyzed using dedicated software. A strain precision of 6×10−4 using a probe size of 2.7 nm with a convergence angle of 0.5 mrad has been reached. The bidimensional distortion tensor in the plane perpendicular to the electron beam has been obtained.

1 July 2017 in Ultramicroscopy
Verified
Journal Article
Closed access
KMKnut Müller-Caspary
Knut Müller-Caspary
FKFlorian F. Krause
Florian F. Krause
TGTim Grieb
Tim Grieb
SLStefan Löffler
Stefan Löffler
MSMarco Schowalter
Marco Schowalter
ARAndreas Rosenauer
Andreas Rosenauer

9 December 2013 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
JRJean-Luc Rouviere
Jean-Luc Rouviere
ABArmand Béché
Armand Béché
YMYannick Martin
Yannick Martin
TDThibaud Denneulin
Thibaud Denneulin
DCDavid Cooper
David Cooper
NanoBeam Electron Diffraction is a simple and efficient technique to measure strain in nanostructures. Here, we show that improved results can be obtained by precessing the electron beam while maintaining a few nanometer probe size, i.e., by doing Nanobeam Precession Electron Diffraction (N-PED). The precession of the beam makes the diffraction spots more uniform and numerous, making N-PED more robust and precise. In N-PED, smaller probe size and better precision are achieved by having diffraction disks instead of diffraction dots. Precision in the strain measurement better than 2 × 10−4 is obtained with a probe size approaching 1 nm in diameter.