Christina M. Webber

Christina M. Webber

Auto-generated profile, based on publicly available information

Christina M. Webber

Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, USA

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 January 2024 in npj Digital Medicine
Verified
Journal Article
Open access
PDF file
ASAubrey A. Shick
Aubrey A. Shick
CWChristina M. Webber
Christina M. Webber
NKNooshin Kiarashi
Nooshin Kiarashi
JWJessica P. Weinberg
Jessica P. Weinberg
ADAneesh Deoras
Aneesh Deoras
MDMatthew C. Diamond
Matthew C. Diamond

1 October 2017 in Prosthetics and Orthotics International
Verified
Journal Article
Closed access
CWChristina M Webber
Christina M Webber
KKKenton Kaufman
Kenton Kaufman
Dynamic elastic response prosthetic feet are designed to mimic the functional characteristics of the native foot/ankle joint. Numerous designs of dynamic elastic response feet exist which make the prescription process difficult, especially because of the lack of empirical evidence describing the objective performance characteristics of the feet. To quantify the mechanical properties of available dynamic elastic response prosthetic feet, specifically the stiffness and hysteresis. Mechanical testing of dynamic elastic response prosthetic feet. Static Proof Testing in accordance with ISO 10328 was conducted on seven dynamic elastic response prosthetic feet. Load–displacement data were used to calculate the instantaneous stiffness in both the heel and forefoot regions, as well as hysteresis associated with each foot. Heel stiffness was greater than forefoot stiffness for all feet. The heel of the glass composite prosthetic foot was stiffer than the carbon fiber feet and it exhibited less hysteresis. Two different carbon fiber feet had the stiffest forefoot regions. Mechanical testing is a reproducible method that can be used to provide objective evidence about dynamic elastic response prosthetic foot performance and aid in the prescription process. The quantitative stiffness and hysteresis data from this study can be used by prosthetists to aid the prescription process and make it more objective.

1 May 2015 in Journal of Biomechanics
Verified
Journal Article
Closed access
CWChristina M. Webber
Christina M. Webber
BDBrian L. Davis
Brian L. Davis

13 April 2020 in Annals of Global Health
Verified
Journal Article
Open access
PDF file
CWChristina M. Webber
Christina M. Webber
GMGabriel Martínez-Gálvez
Gabriel Martínez-Gálvez
MHManuela Lopera Higuita
Manuela Lopera Higuita
EBEphraim I. Ben-Abraham
Ephraim I. Ben-Abraham
BBBrent M. Berry
Brent M. Berry
JWJohn W. Willson
John W. Willson
Engineering technology plays a pivotal role in the delivery of health care in under-resourced countries by providing an infrastructure to improve patient outcomes. However, sustainability of these technologies is difficult in these settings oftentimes due to limited resources or training. The framework presented in this editorial focuses on establishing medical and laboratory equipment sustainability in developing countries and is comprised of four steps: 1) establishing reliable in-country relationships with stakeholders, 2) identifying needs for sustainable solutions locally, 3) exploring potential solutions and assessing their effort-to-impact ratios, and 4) working with strategic partners to implement solutions with clear performance metrics. By focusing on the sustainability of donated equipment instead of the equipment itself, this method presented distinguishes itself from other philanthropic endeavors in the field by seeking to establish preventive maintenance habits that can impact clinical outcomes of a community long term. Application of this methodology is reported in the Original Research Article "A Low-Cost Humidity Control System to Protect Microscopes in a Tropical Climate" by Asp et. al.

1 December 2019 in Clinical Biomechanics
Verified
Journal Article
Closed access
CWChristina M. Webber
Christina M. Webber
ASAlexander Y. Shin
Alexander Y. Shin
KKKenton Kaufman
Kenton Kaufman

12 November 2021 in Prosthetics and Orthotics International
Verified
Journal Article
Closed access
CWChristina M. Webber
Christina M. Webber
JEJason S. Egginton
Jason S. Egginton
ASAlexander Y. Shin
Alexander Y. Shin
KKKenton Kaufman
Kenton Kaufman
Background: Individuals with brachial plexus injuries (BPIs) can be prescribed assistive devices, including myoelectric elbow orthoses (MEOs), for rehabilitation or functional use after failed treatment for elbow flexion restoration. Although recent case studies indicate potential for clinical improvements after using an MEO after BPI, the patients' perspectives on such use are still unknown. Objective: To explore patient perspectives on the use of an MEO after surgical treatment for a traumatic BPI. Study design: Qualitative using both a focus group and semistructured interviews. Methods: Patients with BPI that used an MEO were recruited. Five patients participated in an in-person focus group, whereas three patients participated in individual phone interviews. Themes that emerged from the focus group were compared against those that emerged from the personal interviews. Results: Feedback was grouped into three themes: device usage, hardware performance, and device design. Within each theme, positive elements, areas for improvement, and additional considerations emerged. Patients indicated a positive attitude toward using an MEO as a rehabilitation tool. They desired a streamlined, stronger device to support them and assist during activities of daily living. Conclusions: For patients with BPI, a well-designed MEO that meets their needs could assist with rehabilitation and increase independence in daily activities. Continued patient engagement in the evaluation and development of both medical devices and treatment plans offers the best opportunity for improved outcomes that are important to the patient.