Huiwen He

Huiwen He

Auto-generated profile, based on publicly available information

Huiwen He

State Key Laboratory of Power Grid Environmental Protection, China Electric Power Research Institute, Wuhan 430074, China

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 January 2020 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
LCLei Chen
Lei Chen
GLGuocheng Li
Guocheng Li
HHHuiwen He
Huiwen He
HCHongkun Chen
Hongkun Chen
YLYanhong Li
Yanhong Li
YTYuejin Tang
Yuejin Tang
Directing at the robustness increase of a high voltage direct current (HVDC) system with line commutated converter (LCC) and voltage source converter (VSC), this paper proposes to coordinate resistive superconducting fault current limiters (SFCLs) and hybrid-type DC circuit breakers (HDCBs) for dealing with the DC line fault. The theoretical modeling of the SFCLs is presented, and the DC fault current characteristics are analyzed. Considering that the fault interruption involves multi-stages, the coordination of the SFCL and the HDCB in the LCC/VSC station is elaborated. Using PSCAD/EMTDC, the simulation model of a 320 kV HVDC system is built. Changing the SFCL size and the HDCB operation delay is simulated, and the performance indexes such as the fault current level, breaking time and dissipated energy are compared. The proposed coordination is verified to be very effective in handling the fault. Especially for the VSC station, it enables to visibly limit the fault current rising, shorten the transient voltage duration, and facilitate a significant decrease in the dissipated energy of the HDCB. For the LCC station, the proposed coordination can serve as a competitive backup to ensure a timely fault breaking. Consequently, the DC line fault is removed more rapidly and reliably.

21 December 2018 in Materials
Verified
Journal Article
Open access
PDF file
LCLei Chen
Lei Chen
HHHuiwen He
Huiwen He
GLGuocheng Li
Guocheng Li
HCHongkun Chen
Hongkun Chen
LWLei Wang
Lei Wang
YTYuejin Tang
Yuejin Tang
In this paper, a hybrid high voltage direct current transmission system containing a line commutated converter and a voltage source converter is developed. To enhance the robustness of the hybrid transmission system against direct current short-circuit faults, resistive-type superconducting fault current limiters are applied, and the effectiveness of this approach is assessed. Related mathematical models are built, and the theoretical functions of the proposed approach are expounded. According to the transient simulations in MATLAB software, the results demonstrate that: (i) The superconducting fault current limiter at the voltage source converter station enables to very efficiently mitigate the fault transients, and owns an enhanced current-limiting ability for handling the short-line faults. (ii) The superconducting fault current limiter at the line commutated converter station is able to mildly limit the fault current and alleviate the voltage drop, and its working performance has a low sensitivity to the fault location. At the end of the study, a brief scheme design of the resistive-type superconducting fault current limiters is achieved. In conclusion, the application feasibility of the proposed approach is well confirmed.

21 June 2021 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
LCLei Chen
Lei Chen
RHRuizhe Hu
Ruizhe Hu
XDXinyi Deng
Xinyi Deng
HCHongkun Chen
Hongkun Chen
YLYanhong Li
Yanhong Li
HHHuiwen He
Huiwen He
This paper investigates modified ux-coupling-type superconducting fault current limiters (SFCLs) for enhancing the transient stability of a multi-machine power system (MMPS). The clustering architecture of the MMPS with the modified SFCLs is presented, and the transient energy function (TEF) of the MMPS is established. Through clarifying the potential influence of the modified SFCLs, theoretical analysis signifies that the modified SFCLs can reduce the transient energy accumulation during the fault-feeding period, and increase the transient stability margin of the MMPS. Using MATLAB/Simulink, a benchmark IEEE 9-bus system with the SFCLs is modeled, and the simulation analysis of the generator rotor swing behaviors is carried out. Varying the resistive-inductive parameters and altering the positions of the SFCLs are considered, and the TEF method is applied to gain quantitative effects. The simulation findings in different scenarios testify the correctness of the theoretical analysis. The presence of the SFCLs can availably reduce the generator rotor oscillating and restrain the transient energy changing, and meanwhile, an extension of the critical clearance time is achieved for the MMPS.

14 December 2017 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
LCLei Chen
Lei Chen
HCHongkun Chen
Hongkun Chen
JYJun Yang
Jun Yang
HHHuiwen He
Huiwen He
YYYanjuan Yu
Yanjuan Yu
LRLi Ren
Li Ren
This paper suggests a small-scale superconducting magnetic energy storage (SMES) to enhance the transient behaviors of a 100 kW grid-connected photovoltaic (PV) system, and conducts the conceptual design and performance evaluation. Considering the PV system requirements, the stored energy of the SMES is 90 kJ, and the YBCO tapes are adopted to make a solenoid SMES magnet. Based on the genetic algorithm, the magnet parameters including critical current, tape length, parallel and perpendicular magnetic fields are optimized. Using simulation tools, the effects of the SMES on the PV system are assessed, and the electromagnetic properties, stress and loss of the SMES magnet are analyzed. The results prove that: 1) the SMES improves the fault-ride-through (FRT) capability and realizes an effective protection for the PV system. 2) A relatively large perpendicular magnetic field is found in both ends of the SMES magnet, and the maximum field is induced in the middle of the SMES magnet. 3) The maximum stress of the SMES magnet is acceptable, and the mechanical strength is satisfied. 4) The AC loss is crucial for voltage maintenance performance of the SMES at the fault. Under a short clearance time, the heat accumulation may have a moderate controllability.

9 January 2019 in The Journal of Engineering
Verified
Journal Article
Open access
PDF file
HHHuiwen He
Huiwen He
XLXiaolan Li
Xiaolan Li
YLYing Lou
Ying Lou
LWLei Wang
Lei Wang
PZPeihong Zhou
Peihong Zhou
The ±500 kV half‐bridge modular multilevel converter‐high‐voltage DC (MMC‐HVDC) grid project with overhead transmission line is under construction in China at present. For MMC‐HVDC grid, only one electrical grounding point is allowed and thus, the metal return lines on the same towers with positive and negative polar lines are necessary. However, current studies mainly focused on the control methods of MMC‐HVDC substation and few studies have been done on the transient overvoltage of overhead transmission line for the MMC‐HVDC project. This study analysed the main transient overvoltage types of metal return lines of ±500 kV half‐bridge MMC‐HVDC grid which transmit electric power by overhead lines and clear the grounding fault by DC breakers. Based on a ±500 kV MMC‐HVDC grid project, the simulation models were built using PSCAD and the possible transient overvoltage types were studied. The results showed that the most serious overvoltage was caused by the DC breaker clearing the grounding fault. Then the insulation coordination design for metal return lines was carried out. The recommended arcing horn clearances at different altitude were given. The research results provided support for the insulation design of the transmission line.

17 June 2016 in SpringerPlus
Verified
Journal Article
Open access
PDF file
LCLei Chen
Lei Chen
HCHongkun Chen
Hongkun Chen
JYJun Yang
Jun Yang
ZSZhengyu Shu
Zhengyu Shu
HHHuiwen He
Huiwen He
XSXin Shu
Xin Shu
The modified flux-coupling-type superconducting fault current (SFCL) is a high-efficient electrical auxiliary device, whose basic function is to suppress the short-circuit current by controlling the magnetic path through a high-speed switch. In this paper, the high-speed switch is based on electromagnetic repulsion mechanism, and its conceptual design is carried out to promote the application of the modified SFCL. Regarding that the switch which is consisting of a mobile copper disc, two fixed opening and closing coils, the computational method for the electromagnetic force is discussed, and also the dynamic mathematical model including circuit equation, magnetic field equation as well as mechanical motion equation is theoretically deduced. According to the mathematical modeling and calculation of characteristic parameters, a feasible design scheme is presented, and the high-speed switch’s response time can be less than 0.5 ms. For that the modified SFCL is equipped with this high-speed switch, the SFCL’s application in a 10 kV micro-grid system with multiple renewable energy sources are assessed in the MATLAB software. The simulations are well able to affirm the SFCL’s performance behaviors.