KunHyuck Lee

KunHyuck Lee

Auto-generated profile, based on publicly available information

KunHyuck Lee

Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 March 2020 in Nature Medicine
Verified
Journal Article
Open access
PDF file
HCHa Uk Chung
Ha Uk Chung
ARAlina Y. Rwei
Alina Y. Rwei
AHAurélie Hourlier-Fargette
Aurélie Hourlier-Fargette
SXShuai Xu
Shuai Xu
KLKunHyuck Lee
KunHyuck Lee
John A. RogersJohn A. Rogers
John A. Rogers
Standard clinical care in neonatal and pediatric intensive-care units (NICUs and PICUs, respectively) involves continuous monitoring of vital signs with hard-wired devices that adhere to the skin and, in certain instances, can involve catheter-based pressure sensors inserted into the arteries. These systems entail risks of causing iatrogenic skin injuries, complicating clinical care and impeding skin-to-skin contact between parent and child. Here we present a wireless, non-invasive technology that not only offers measurement equivalency to existing clinical standards for heart rate, respiration rate, temperature and blood oxygenation, but also provides a range of important additional features, as supported by data from pilot clinical studies in both the NICU and PICU. These new modalities include tracking movements and body orientation, quantifying the physiological benefits of skin-to-skin care, capturing acoustic signatures of cardiac activity, recording vocal biomarkers associated with tonality and temporal characteristics of crying and monitoring a reliable surrogate for systolic blood pressure. These platforms have the potential to substantially enhance the quality of neonatal and pediatric critical care.

23 April 2021 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
PDF file
XNXiaoyue Ni
Xiaoyue Ni
WOWei Ouyang
Wei Ouyang
HJHyoyoung Jeong
Hyoyoung Jeong
JKJin-Tae Kim
Jin-Tae Kim
ATAndreas Tzavelis
Andreas Tzavelis
John A. RogersJohn A. Rogers
John A. Rogers
Significance: Continuous measurements of health status can be used to guide the care of patients and to manage the spread of infectious diseases. Conventional monitoring systems cannot be deployed outside of hospital settings, and existing wearables cannot capture key respiratory biomarkers. This paper describes an automated wireless device and a data analysis approach that overcome these limitations, tailored for COVID-19 patients, frontline health care workers, and others at high risk. Vital signs and respiratory activity such as cough can reveal early signs of infection and quantitate responses to therapeutics. Long-term trials on COVID-19 patients in clinical and home settings demonstrate the translational value of this technology.

18 October 2021 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
PDF file
HJHyoyoung Jeong
Hyoyoung Jeong
SKSung Soo Kwak
Sung Soo Kwak
SSSeokwoo Sohn
Seokwoo Sohn
JLJong Yoon Lee
Jong Yoon Lee
YLYoung Joong Lee
Young Joong Lee
John A. RogersJohn A. Rogers
John A. Rogers
Significance: Early detection of infant neuromotor pathologies is critical for timely therapeutic interventions that rely on early-life neuroplasticity. Traditional assessments rely on subjective expert evaluations or specialized medical facilities, making them challenging to scale in remote and/or resource-constrained settings. The results presented here aim to democratize these evaluations using wireless networks of miniaturized, skin-integrated sensors that digitize movement behaviors and vital signs of infants in a cost-effective manner. The resulting data yield full-body motion reconstructions in the form of deidentified infant avatars, along with a range of important cardiopulmonary information. This technology approach enables rapid, routine evaluations of infants at any age via an engineering platform that has potential for use in nearly any setting across developed and developing countries alike.

2 December 2020 in Research Square
Verified
Preprint
Open access
PDF file
John A. RogersJohn A. Rogers
John A. Rogers
XNXiaoyue Ni
Xiaoyue Ni
WOWei Ouyang
Wei Ouyang
HJHyoyoung Jeong
Hyoyoung Jeong
JKJin-Tae Kim
Jin-Tae Kim
SXShuai Xu
Shuai Xu
Capabilities in continuous monitoring of key physiological parameters of disease have never been more important than in the context of the global COVID-19 pandemic. Soft, skin-mounted electronics that incorporate high-bandwidth, miniaturized motion sensors represent a powerful class of technology for digital, wireless measurements of mechano-acoustic (MA) signatures of both core vital signs (heart rate, respiratory rate, and temperature) and underexplored biomarkers (coughing count) with high fidelity and immunity to ambient noises. Here, we introduce an effort that integrates such an MA sensor, a cloud data infrastructure and data analytics approaches based on digital filtering and convolutional neural networks for comprehensive monitoring of COVID-19 infections in sick and healthy individuals in a population, both in the hospital and the home. This hardware/software system extracts diverse signatures of health status in an automated fashion from a single device and time series data stream. Unique features are in quantitative measurements of coughing and other vocal events, as indicators of both disease and infectiousness. Systematic imaging studies demonstrate direct correlations between the time and intensity of coughing, speaking and laughing and the total droplet production, as an approximate indicator of the probability for disease spread. The sensors, deployed on COVID-19 patients along with healthy controls in both inpatient and home settings, record coughing frequency and intensity continuously, along with a comprehensive collection of other biometrics, with recording times for individuals of more than a month after disease diagnosis. These pilot studies include 3,111 hours of data spanning 363 days from 37 COVID-19 patients (20 females, 17 males) with 27,651 coughs detected in total along with continuous measurements of heart rate, respiratory rate, physical activity, and skin temperature. Manual labeling of randomly sampled 10,258 vocal events from 11 COVID-19 patients (6 females, 5 males) suggests a sensitivity of 85% and a specificity of 96% in cough detection using automated algorithms. The collective results indicate a decaying trend of coughing frequency and intensity through the course of disease recovery, but with wide variations across patient populations. The methodology also opens opportunities to study patterns in biometrics across individuals and among different demographic groups.