Charlotte A. Scarff

Charlotte A. Scarff

Auto-generated profile, based on publicly available information

Charlotte A. Scarff

University of Leeds

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 May 2018 in Acta Crystallographica Section D Structural Biology
Verified
Journal Article
Open access
PDF file
IDIeva Drulyte
Ieva Drulyte
RJRachel M. Johnson
Rachel M. Johnson
EHEmma L. Hesketh
Emma L. Hesketh
DHDaniel Hurdiss
Daniel Hurdiss
CSCharlotte A. Scarff
Charlotte A. Scarff
RTRebecca F. Thompson
Rebecca F. Thompson
Cryo-electron microscopy (cryo-EM) can now be used to determine high-resolution structural information on a diverse range of biological specimens. Recent advances have been driven primarily by developments in microscopes and detectors, and through advances in image-processing software. However, for many single-particle cryo-EM projects, major bottlenecks currently remain at the sample-preparation stage; obtaining cryo-EM grids of sufficient quality for high-resolution single-particle analysis can require the careful optimization of many variables. Common hurdles to overcome include problems associated with the sample itself (buffer components, labile complexes), sample distribution (obtaining the correct concentration, affinity for the support film), preferred orientation, and poor reproducibility of the grid-making process within and between batches. This review outlines a number of methodologies used within the electron-microscopy community to address these challenges, providing a range of approaches which may aid in obtaining optimal grids for high-resolution data collection.

24 September 2008 in Rapid Communications in Mass Spectrometry
Verified
Journal Article
Closed access
PDF file
CSCharlotte A. Scarff
Charlotte A. Scarff
KTKonstantinos Thalassinos
Konstantinos Thalassinos
GHGillian R. Hilton
Gillian R. Hilton
JSJames H. Scrivens
James H. Scrivens

5 September 2019 in IUCrJ
Verified
Journal Article
Open access
PDF file
Dimitrios KontziampasisDimitrios Kontziampasis
Dimitrios Kontziampasis
DKDavid P. Klebl
David P. Klebl
MIMatthew G. Iadanza
Matthew G. Iadanza
CSCharlotte A. Scarff
Charlotte A. Scarff
FKFlorian Kopf
Florian Kopf
HWHoward D. White
Howard D. White
Structural biology generally provides static snapshots of protein conformations that can provide information on the functional mechanisms of biological systems. Time-resolved structural biology provides a means to visualize, at near-atomic resolution, the dynamic conformational changes that macromolecules undergo as they function. X-ray free-electron-laser technology has provided a powerful tool to study enzyme mechanisms at atomic resolution, typically in the femtosecond to picosecond timeframe. Complementary to this, recent advances in the resolution obtainable by electron microscopy and the broad range of samples that can be studied make it ideally suited to time-resolved approaches in the microsecond to millisecond timeframe to study large loop and domain motions in biomolecules. Here we describe a cryo-EM grid preparation device that permits rapid mixing, voltage-assisted spraying and vitrification of samples. It is shown that the device produces grids of sufficient ice quality to enable data collection from single grids that results in a sub-4 Å reconstruction. Rapid mixing can be achieved by blot-and-spray or mix-and-spray approaches with a delay of ∼10 ms, providing greater temporal resolution than previously reported mix-and-spray approaches.

1 February 2018 in Biochimica et Biophysica Acta (BBA) - Biomembranes
Verified
Journal Article
Open access
MPMayuriben Parmar
Mayuriben Parmar
SRShaun Rawson
Shaun Rawson
CSCharlotte A. Scarff
Charlotte A. Scarff
AGAdrian Goldman
Adrian Goldman
TDTimothy R. Dafforn
Timothy R. Dafforn
Vincent L. G. PostisVincent L. G. Postis
Vincent L. G. Postis
The field of membrane protein structural biology has been revolutionized over the last few years with a number of high profile structures being solved using cryo-EM including Piezo, Ryanodine receptor, TRPV1 and the Glutamate receptor. Further developments in the EM field hold the promise of even greater progress in terms of greater resolution, which for membrane proteins is still typically within the 4-7Å range. One advantage of a cryo-EM approach is the ability to study membrane proteins in more "native" like environments for example proteoliposomes, amphipols and nanodiscs. Recently, styrene maleic acid co-polymers (SMA) have been used to extract membrane proteins surrounded by native lipids (SMALPs) maintaining a more natural environment. We report here the structure of the Escherichia coli multidrug efflux transporter AcrB in a SMALP scaffold to sub-nm resolution, with the resulting map being consistent with high resolution crystal structures and other EM derived maps. However, both the C-terminal helix (TM12) and TM7 are poorly defined in the map. These helices are at the exterior of the helical bundle and form the greater interaction with the native lipids and SMA polymer and may represent a more dynamic region of the protein. This work shows the promise of using an SMA approach for single particle cryo-EM studies to provide sub-nm structures.

30 September 2014 in Analytical Chemistry
Verified
Journal Article
Closed access
JHJohanna Hofmann
Johanna Hofmann
WSWeston B. Struwe
Weston B. Struwe
CSCharlotte A. Scarff
Charlotte A. Scarff
JSJames H. Scrivens
James H. Scrivens
DHDavid J. Harvey
David J. Harvey
KPKevin Pagel
Kevin Pagel

2 December 2020 in Nature
Verified
Journal Article
Closed access
PDF file
CSCharlotte A. Scarff
Charlotte A. Scarff
GCGlenn Carrington
Glenn Carrington
DCDavid Casas-Mao
David Casas-Mao
JCJoseph M. Chalovich
Joseph M. Chalovich
PKPeter J. Knight
Peter J. Knight
MPMichelle Peckham
Michelle Peckham