Weerawat Charoensiri

Weerawat Charoensiri

Auto-generated profile, based on publicly available information

Weerawat Charoensiri

School of Electronic Engineering, Institute of Engineering, Suranaree University of Technology, Nakhon Ratchasima, Thailand

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 May 2025 in IEEE Access
Verified
Journal Article
Open access
Pisit JanpangngernPisit Janpangngern
Pisit Janpangngern
PCP. Changnam
P. Changnam
WCW. Charoensiri
W. Charoensiri
SSS. Samroeng
S. Samroeng
JPJariya Pakprom
Jariya Pakprom
SSSamran Santalunai
Samran Santalunai
This article presents a threat detection system for Unmanned Aerial Vehicles (UAVs) designed to enhance operational security in high-risk environments. The system employs Frequency Modulated Continuous Wave (FMCW) radar, optimized to detect UAVs with a radar cross section (RCS) as small as 0.01 m², exemplified by models such as the DJI Phantom 3 and Phantom 4. Operating at 2.45 GHz, the radar achieves a maximum detection range of 300 meters and is implemented on the USRP B210 Software Defined Radio (SDR) platform, with real-time signal processing enabled through GNU Radio and integrated GPU resources. The transmission module includes a 100-watt Power Amplifier (PA) and dual-parabolic unidirectional antennas, while the receiver employs a Band-Pass Filter (BPF) and a Low Noise Amplifier (LNA) with a gain of 20 dB to improve sensitivity to reflected signals. The USRP B210 handles signal acquisition and processing, applying two-dimensional Fast Fourier Transform (FFT) techniques to extract doppler shift information. The processed data is visualized as a range-doppler map, facilitating effective target tracking. The system's modular architecture and parallel processing capability enable precise and efficient detection of low-RCS UAVs, even in cluttered environments. This work demonstrates a practical, cost-effective radar solution for security-sensitive applications, offering advantages in performance, adaptability, and real-time capability over traditional radar systems.

9 August 2024 in Heliyon
Verified
Journal Article
Open access
SSSamroeng Santalunai
Samroeng Santalunai
JPJariya Pakprom
Jariya Pakprom
WCWeerawat Charoensiri
Weerawat Charoensiri
CTChanchai Thongsopa
Chanchai Thongsopa
TTThanaset Thosdeekoraphat
Thanaset Thosdeekoraphat
SSSamran Santalunai
Samran Santalunai
This research investigated the effectiveness of radio frequency (RF) heating as a treatment for lead-contaminated soil, assessing its impact through dielectric constant measurements. Using water-soluble lead (II) acetate trihydrate, the study analyzed the impact of RF heating on soil dielectric properties under various soil moisture conditions (high, medium, and low) and electric field strengths (112.5, 150, 225, and 450 kV/m). The results indicated that soil temperature increased with lead concentration, highlighting significant changes in soil thermodynamics. Under high-humidity conditions, temperature increases were more pronounced, suggesting that higher lead concentrations elevate soil temperatures. Moreover, RF heating consistently reduced the dielectric constant as lead concentration increased, which was especially evident at higher electric field strengths. The study found that the soil resistivity approached that of uncontaminated soil, particularly at 450 kV/m electric field strength, with the highest removal rate of 46.154%. This investigation provides valuable insights into the application of RF heating for soil quality improvement in lead-contaminated environments, demonstrating how dielectric properties can reflect those of uncontaminated soil.

9 September 2024 in IEEE Access
Verified
Journal Article
Open access
SSS. Samroeng
S. Samroeng
JPJariya Pakprom
Jariya Pakprom
WCW. Charoensiri
W. Charoensiri
CTC. Thongsopa
C. Thongsopa
TTThanaset Thosdeekoraphat
Thanaset Thosdeekoraphat
SSSamran Santalunai
Samran Santalunai
This research investigates the use of cold plasma technology, specifically negative corona discharge, for the efficient and cost-effective decomposition of carbon dioxide (CO 2 ) to reduce air pollution. Using specially designed copper electrodes with pointed triangular tips and an aluminum ground plate, the study evaluates CO 2 decomposition under varied states of electric field intensities (Glow, Streamer, and Electric Field Strength) and airflow rates. The experimental achieved a maximum CO 2 decomposition efficiency of 96.44% at the Electric Field Strength level with a 40 L/min airflow rate. However, this process also generated significant byproducts, notably ozone (O3) at 8.4 ppm and nitrogen oxides (NOx) at 34 ppm, illustrating the relationship between electric field intensity, CO 2 decomposition efficiency, and byproduct generation. Additionally, the study examines the impact of varying CO 2 concentrations on decomposition efficiency and byproduct formation at the Electric Field Strength state, finding that higher CO 2 concentrations increase decomposition efficiency and decrease byproduct levels. This research demonstrates the potential of corona discharge plasma, with its low-temperature operation and scalability, as a promising tool for advancing Carbon Capture, Utilization, and Storage (CCUS) technologies and mitigating air pollution.