31 October 2024 in Journal of Lightwave Technology
Complete ensemble empirical mode decomposition with adaptive noise (CEEMDAN) addresses the incomplete decomposition problem in ensemble empirical mode decomposition (EEMD) during the ensemble averaging process, but the residual noise in intrinsic mode function (IMF) severely affect the decomposition results and the efficiency of the algorithm. To address the shortcomings of CEEMDAN, improved complete ensemble empirical mode decomposition with adaptive noise (ICEEMDAN) algorithm is presented. This method introduces pairs of Gaussian white noise with opposite amplitudes to assist in the decomposition of original signal. The final IMF is the ensemble of both the IMFs with positive and negative noises, where the introduced noise can be effectively neutralized. Simulation and experimental results indicate that ICEEMDAN has advantages in improving the efficiency and decomposition accuracy of the algorithm. The proposed approach was applied to signal denoising in fiber optic sensing, and the analysis results verified the effectiveness and superiority of the method.
5 June 2024 in Optics Express
In this paper, a fiber optic sensor with draw-tower-grating (DTG)-based Fabry-Perot interferometers (FPIs) are proposed to measure the temperature and salinity of seawater simultaneously. The sensing structure utilizes DTG as the reflector, and two adjacent gratings can be cascaded to compose an FPI. By employing moisture-sensitive materials to the surface of the optical fiber, the variation in salinity can be measured by the axial strain applied by the coating on the sensing optical fiber. The salinity altering causes swelling or shrinking actions of the coating through absorbing or releasing water. Two different moisture-sensitive materials are chosen to eliminate the cross-sensitivity of temperature and salinity. The experimental results show that the sensor exhibits linear response to temperature and salinity changes with good repeatability and stability, and the temperature and salinity sensitivities are 12308.65 rad/°C and 95.02 rad/‰, respectively. The optical path configuration of the DTG sensing array matching compensation interferometer provides the possibility for efficient distributed solutions, which has promising potential for application in marine engineering.
24 May 2024 in Optics & Laser Technology
23 July 2025 in Optics & Laser Technology
4 November 2025 in Journal of Lightwave Technology
In 3×3 coupler-based interferometric systems, the phase demodulation accuracy is affected by light source fluctuations and unequal coupler splitting ratios. Existing algorithms face challenges in simultaneously suppressing fluctuations in the light source and compensating for splitting ratio deviations in the coupler. To address this issue, an improved 3×3 coupler demodulation algorithm is proposed to achieve high-precision phase extraction. The algorithm employs ellipse fitting algorithm (EFA) to calibrate the direct current (DC) components and fringe visibility of the three interference signals. One interference signal is selected as the reference, and the remaining two signals are differentially processed against the reference to eliminate the influence of DC components. A system of equations is constructed to obtain a set of orthogonal components containing the desired phase signal, thus achieving effective compensation for asymmetries in the coupler's splitting ratio. The alternating current (AC) component coefficients in the orthogonal signals are effectively removed during the arctangent processing. Simulation results demonstrate that the orthogonal components obtains a Lissajous diagram characterized by a smooth, low-fluctuation, and highly uniform circular trajectory. The average relative error between the demodulated phase and the original signal is as low as 0.004%. Temperature sensing experiments confirm that the algorithm achieves an ultra-high sensitivity of 11,941 rad/°C with the coefficient of determination (R²) as high as 0.9992. Moreover, the average absolute error in temperature measurement is as low as 0.0055°C, demonstrating the outstanding precision and reliability of the proposed scheme. Owing to the high-precision and high-stability demodulation performance, the algorithm demonstrates significant application potential in interferometric systems based on 3×3 coupler.