Oscar Calderon Agudo

Oscar Calderon Agudo

Auto-generated profile, based on publicly available information

Oscar Calderon Agudo

Imperial College London (United Kingdom)

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 March 2020 in npj Digital Medicine
Verified
Journal Article
Open access
PDF file
LBLluis Guasch Batalla
Lluis Guasch Batalla
OAOscar Calderón Agudo
Oscar Calderón Agudo
MTMeng-Xing Tang
Meng-Xing Tang
PNParashkev Nachev
Parashkev Nachev
MWMichael Warner
Michael Warner
Magnetic resonance imaging and X-ray computed tomography provide the two principal methods available for imaging the brain at high spatial resolution, but these methods are not easily portable and cannot be applied safely to all patients. Ultrasound imaging is portable and universally safe, but existing modalities cannot image usefully inside the adult human skull. We use in silico simulations to demonstrate that full-waveform inversion, a computational technique originally developed in geophysics, is able to generate accurate three-dimensional images of the brain with sub-millimetre resolution. This approach overcomes the familiar problems of conventional ultrasound neuroimaging by using the following: transcranial ultrasound that is not obscured by strong reflections from the skull, low frequencies that are readily transmitted with good signal-to-noise ratio, an accurate wave equation that properly accounts for the physics of wave propagation, and adaptive waveform inversion that is able to create an accurate model of the skull that then compensates properly for wavefront distortion. Laboratory ultrasound data, using ex vivo human skulls and in vivo transcranial signals, demonstrate that our computational experiments mimic the penetration and signal-to-noise ratios expected in clinical applications. This form of non-invasive neuroimaging has the potential for the rapid diagnosis of stroke and head trauma, and for the provision of routine monitoring of a wide range of neurological conditions.

2 April 2024 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
RARehman Ali
Rehman Ali
TMTrevor M. Mitcham
Trevor M. Mitcham
TBThurston Brevett
Thurston Brevett
ÒAÒscar Calderón Agudo
Òscar Calderón Agudo
CMCristina Durán Martinez
Cristina Durán Martinez
NDNebojsa Duric
Nebojsa Duric
Ultrasound tomography is an emerging imaging modality that uses the transmission of ultrasound through tissue to reconstruct images of its mechanical properties. Initially, ray-based methods were used to reconstruct these images, but their inability to account for diffraction often resulted in poor resolution. Waveform inversion overcame this limitation, providing high-resolution images of the tissue. Most clinical implementations, often directed at breast cancer imaging, currently rely on a frequency-domain waveform inversion to reduce computation time. For ring arrays, ray tomography was long considered a necessary step prior to waveform inversion in order to avoid cycle skipping. However, in this paper, we demonstrate that frequency-domain waveform inversion can reliably reconstruct high-resolution images of sound speed and attenuation without relying on ray tomography to provide an initial model. We provide a detailed description of our frequency-domain waveform inversion algorithm with open-source code and data that we make publicly available.

3 July 2021 in Sensors
Verified
Journal Article
Open access
PDF file
TRThomas Robins
Thomas Robins
Jorge CamachoJorge Camacho
Jorge Camacho
OAOscar Calderon Agudo
Oscar Calderon Agudo
JHJOAQUIN L. HERRAIZ
JOAQUIN L. HERRAIZ
LBLluis Guasch Batalla
Lluis Guasch Batalla
Ultrasound breast imaging is a promising alternative to conventional mammography because it does not expose women to harmful ionising radiation and it can successfully image dense breast tissue. However, conventional ultrasound imaging only provides morphological information with limited diagnostic value. Ultrasound computed tomography (USCT) uses energy in both transmission and reflection when imaging the breast to provide more diagnostically relevant quantitative tissue properties, but it is often based on time-of-flight tomography or similar ray approximations of the wave equation, resulting in reconstructed images with low resolution. Full-waveform inversion (FWI) is based on a more accurate approximation of wave-propagation phenomena and can consequently produce very high resolution images using frequencies below 1 megahertz. These low frequencies, however, are not available in most USCT acquisition systems, as they use transducers with central frequencies well above those required in FWI. To circumvent this problem, we designed, trained, and implemented a two-dimensional convolutional neural network to artificially generate missing low frequencies in USCT data. Our results show that FWI reconstructions using experiment data after the application of the proposed method successfully converged, showing good agreement with X-ray CT and reflection ultrasound-tomography images.

14 March 2022 in Inverse Problems
Verified
Journal Article
Open access
OBOscar Bates
Oscar Bates
LBLluis Guasch Batalla
Lluis Guasch Batalla
GSGeorge Strong
George Strong
TRThomas Robins
Thomas Robins
OCOscar Calderon-Agudo
Oscar Calderon-Agudo
MTMengxing Tang
Mengxing Tang
Bayesian methods are a popular research direction for inverse problems. There are a variety of techniques available to solve Bayes’ equation, each with their own strengths and limitations. Here, we discuss stochastic variational inference (SVI), which solves Bayes’ equation using gradient-based methods. This is important for applications which are time-limited (e.g. medical tomography) or where solving the forward problem is expensive (e.g. adjoint methods). To evaluate the use of SVI in both these contexts, we apply it to ultrasound tomography of the brain using full-waveform inversion (FWI). FWI is a computationally expensive adjoint method for solving the ultrasound tomography inverse problem, and we demonstrate that SVI can be used to find a no-cost estimate of the pixel-wise variance of the sound-speed distribution using a mean-field Gaussian approximation. In other words, we show experimentally that it is possible to estimate the pixel-wise uncertainty of the sound-speed reconstruction using SVI and a common approximation which is already implicit in other types of iterative reconstruction. Uncertainty estimates have a variety of uses in adjoint methods and tomography. As an illustrative example, we focus on the use of uncertainty for image quality assessment. This application is not limiting; our variance estimator has effectively no computational cost and we expect that it will have applications in fields such as non-destructive testing or aircraft component design where uncertainties may not be routinely estimated.

12 August 2021 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
CCCarlos Cueto
Carlos Cueto
LGLluis Guasch
Lluis Guasch
JCJavier Cudeiro
Javier Cudeiro
OAOscar Calderon Agudo
Oscar Calderon Agudo
TRThomas Robins
Thomas Robins
MTMeng-Xing Tang
Meng-Xing Tang
Ultrasound computed tomography techniques have the potential to provide clinicians with 3-D, quantitative and high-resolution information of both soft and hard tissues such as the breast or the adult human brain. Their practical application requires accurate modeling of the acquisition setup: the spatial location, orientation, and impulse response (IR) of each ultrasound transducer. However, the existing calibration methods fail to accurately characterize these transducers unless their size can be considered negligible when compared with the dominant wavelength, which reduces signal-to-noise ratios below usable levels in the presence of high-contrast tissues such as the skull. In this article, we introduce a methodology that can simultaneously estimate the location, orientation, and IR of the ultrasound transducers in a single calibration. We do this by extending spatial response identification (SRI), an algorithm that we have recently proposed to estimate transducer IRs. Our proposed methodology replaces the transducers in the acquisition device with a surrogate model whose effective response matches the experimental data by fitting a numerical model of wave propagation. This results in a flexible and robust calibration procedure that can accurately predict the behavior of the ultrasound acquisition device without ever having to know where the real transducers are or their individual IR. Experimental results using a ring acquisition system show that SRI produces calibrations of significantly higher quality than standard methodologies across all transducers, both in transmission and in reception. Experimental full-waveform inversion (FWI) reconstructions of a tissue-mimicking phantom demonstrate that SRI generates more accurate reconstructions than those produced with standard calibration techniques.

18 December 2019 in Geophysical Journal International
Verified
Journal Article
Open access
ÒAÒscar Calderón Agudo
Òscar Calderón Agudo
NSNuno Vieira da Silva
Nuno Vieira da Silva
GSGeorge Stronge
George Stronge
MWMichael Warner
Michael Warner
SUMMARY: The potential of full-waveform inversion (FWI) to recover high-resolution velocity models of the subsurface has been demonstrated in the last decades with its application to field data. But in certain geological scenarios, conventional FWI using the acoustic wave equation fails in recovering accurate models due to the presence of strong elastic effects, as the acoustic wave equation only accounts for compressional waves. This becomes more critical when dealing with land data sets, in which elastic effects are generated at the source and recorded directly by the receivers. In marine settings, in which sources and receivers are typically within the water layer, elastic effects are weaker but can be observed most easily as double mode conversions and through their effect on P-wave amplitudes. Ignoring these elastic effects can have a detrimental impact on the accuracy of the recovered velocity models, even in marine data sets. Ideally, the elastic wave equation should be used to model wave propagation, and FWI should aim to recover anisotropic models of velocity for P waves (vp) and S waves (vs). However, routine three-dimensional elastic FWI is still commercially impractical due to the elevated computational cost of modelling elastic wave propagation in regions with low S-wave velocity near the seabed. Moreover, elastic FWI using local optimization methods suffers from cross-talk between different inverted parameters. This generally leads to incorrect estimation of subsurface models, requiring an estimate of vp/vs that is rarely known beforehand. Here we illustrate how neglecting elasticity during FWI for a marine field data set that contains especially strong elastic heterogeneities can lead to an incorrect estimation of the P-wave velocity model. We then demonstrate a practical approach to mitigate elastic effects in 3-D yielding improved estimates, consisting of using a global inversion algorithm to estimate a model of vp/vs, employing matching filters to remove elastic effects from the field data, and performing acoustic FWI of the resulting data set. The quality of the recovered models is assessed by exploring the continuity of the events in the migrated sections and the fit of the latter with the recovered velocity model.