1 April 2018 in Radiology
Dynamic contrast-enhanced MR imaging and the iterative decomposition of water and fat with echo asymmetry and least-squares estimation quantitation sequence can be used to quantitatively evaluate changes in vertebral microvascular permeability and vertebral fat deposition in alloxan-induced diabetic rabbits, which are highly associated with increasing vertebral fat deposition. Purpose To determine longitudinal relationships between lumbar vertebral bone marrow permeability and marrow adipose tissue in a rabbit diabetes model by using quantitative dynamic contrast agent–enhanced (DCE) magnetic resonance (MR) imaging and iterative decomposition of water and fat with the echo asymmetry and least-squares estimation quantitation (IDEAL IQ) sequence. Materials and Methods Twenty rabbits were randomly assigned to the diabetic (n = 10) or control (n = 10) group. All rabbits underwent sagittal MR imaging of the lumbar region at fixed time points (0, 4, 8, 12, and 16 weeks after alloxan injection). A linear mixed-effects model was used to analyze fat fraction (FF) and permeability parameter changes for 16 months after baseline. These parameters were compared between the two groups by using an independent-samples t test. Correlation of DCE MR imaging parameters with FF and with microvessel density (MVD) was analyzed by using the Spearman correlation coefficient. All statistical analyses w...
1 September 2021 in Radiology: Artificial Intelligence
“Just Accepted” papers have undergone full peer review and have been accepted for publication in Radiology: Artificial Intelligence. This article will undergo copyediting, layout, and proof review ...
4 April 2024 in IEEE Journal of Biomedical and Health Informatics
Magnetic resonance imaging (MRI)-based deep neural networks (DNN) have been widely developed to perform prostate cancer (PCa) classification. However, in real-world clinical situations, prostate MRIs can be easily impacted by rectal artifacts, which have been found to lead to incorrect PCa classification. Existing DNN-based methods typically do not consider the interference of rectal artifacts on PCa classification, and do not design specific strategy to address this problem. In this study, we proposed a novel Targeted adversarial training with Proprietary Adversarial Samples (TPAS) strategy to defend the PCa classification model against the influence of rectal artifacts. Specifically, based on clinical prior knowledge, we generated proprietary adversarial samples with rectal artifact-pattern adversarial noise, which can severely mislead PCa classification models optimized by the ordinary training strategy. We then jointly exploited the generated proprietary adversarial samples and original samples to train the models. To demonstrate the effectiveness of our strategy, we conducted analytical experiments on multiple PCa classification models. Compared with ordinary training strategy, TPAS can effectively improve the single- and multi-parametric PCa classification at patient, slice and lesion level, and bring substantial gains to recent advanced models. In conclusion, TPAS strategy can be identified as a valuable way to mitigate the influence of rectal artifacts on deep learning models for PCa classification.
1 March 2024 in Radiology: Artificial Intelligence
"Just Accepted" papers have undergone full peer review and have been accepted for publication in Radiology: Artificial Intelligence. This article will undergo copyediting, layout, and proof review before it is published in its final version. Please note that during production of the final copyedited article, errors may be discovered which could affect the content. Purpose To develop an MRI-based model for clinically significant prostate cancer (csPCa) diagnosis that can resist rectal artifact interference. Materials and Methods This retrospective study included 2203 male patients with prostate lesions who underwent biparametric MRI and biopsy between January 2019 and June 2023. A targeted adversarial training with proprietary adversarial samples (TPAS) strategy was proposed to enhance model resistance against rectal artifacts. The automated csPCa diagnostic models trained with and without TPAS were compared using multicenter validation datasets. The impact of rectal artifacts on diagnostic performance of each model at the patient and lesion levels was compared using the area under the receiver operating characteristic curve (AUC) and the area under the precision-recall curve (AUPRC). The AUC between models was compared using the Delong test, and the AUPRC was compared using the bootstrap method. Results The TPAS model exhibited diagnostic performance improvements of 6% at the patient level (AUC: 0.87 versus 0.81; P < .001) and 7% at the lesion level (AUPRC: 0.84 versus 0.77; P = .007) compared with the control model. The TPAS model demonstrated less performance decline in the presence of rectal artifact-pattern adversarial noise than the control model (ΔAUC: -17% versus -19%; ΔAUPRC: -18% versus -21%). The TPAS model performed better than the control model in patients with moderate (AUC: 0.79 versus 0.73; AUPRC: 0.68 versus 0.61), and severe (AUC: 0.75 versus 0.57; AUPRC: 0.69 versus 0.59) artifacts. Conclusion This study demonstrates that the TPAS model can reduce rectal artifact interference in MRI-based PCa diagnosis, thereby improving its performance in clinical applications. Published under a CC BY 4.0 license.
4 December 2024 in Cancer Research
The batch effect is a nonbiological variation that arises from technical differences across different batches of data during the data generation process for acquisition-related reasons, such as collection of images at different sites or using different scanners. This phenomenon can affect the robustness and generalizability of computational pathology- or radiology-based cancer diagnostic models, especially in multicenter studies. To address this issue, we developed an open-source platform, Batch Effect Explorer (BEEx), that is designed to qualitatively and quantitatively determine whether batch effects exist among medical image datasets from different sites. A suite of tools was incorporated into BEEx that provide visualization and quantitative metrics based on intensity, gradient, and texture features to allow users to determine whether there are any image variables or combinations of variables that can distinguish datasets from different sites in an unsupervised manner. BEEx was designed to support various medical imaging techniques, including microscopy and radiology. Four use cases clearly demonstrated the ability of BEEx to identify batch effects and validated the effectiveness of rectification methods for batch effect reduction. Overall, BEEx is a scalable and versatile framework designed to read, process, and analyze a wide range of medical images to facilitate the identification and mitigation of batch effects, which can enhance the reliability and validity of image-based studies. Significance: BEEx is a prescreening tool for image-based analyses that allows researchers to evaluate batch effects in multicenter studies and determine their origin and magnitude to facilitate development of accurate AI–based cancer models.
25 February 2025 in BMC Medical Imaging
To compare the influence of rectal susceptibility artifacts on the subjective evaluation and deep learning (DL) in prostate cancer (PCa) diagnosis. This retrospective two-center study included 1052 patients who underwent MRI and biopsy due to clinically suspected PCa between November 2019 and November 2023. The extent of rectal artifacts in these patients’ images was evaluated using the Likert four-level method. The PCa diagnosis was performed by six radiologists and an automated PCa diagnosis DL method. The performance of DL and radiologists was evaluated using the area under the receiver operating characteristic curve (AUC) and the area under the multi-reader multi-case receiver operating characteristic curve, respectively. Junior radiologists and DL demonstrated statistically significantly higher AUCs in patients without artifacts compared to those with artifacts (R1: 0.73 vs. 0.64; P = 0.01; R2: 0.74 vs. 0.67; P = 0.03; DL: 0.77 vs. 0.61; P < 0.001). In subgroup analysis, no statistically significant differences in the AUC were observed among different grades of rectal artifacts for both all radiologists (0.08 ≤ P ≤ 0.90) and DL models (0.12 ≤ P ≤ 0.96). The AUC for DL without artifacts significantly exceeded those with artifacts in both the peripheral zone (PZ) and transitional zone (TZ) (DLPZ: 0.78 vs. 0.61; P = 0.003; DLTZ: 0.73 vs. 0.59; P = 0.011). Conversely, there were no statistically significant differences in AUC with and without artifacts for all radiologists in PZ and TZ (0.08 ≤ P ≤ 0.98). Rectal susceptibility artifacts have significant negative effects on subjective evaluation of junior radiologists and DL. Not applicable.