Pierre-Allain Duvillard

Pierre-Allain Duvillard

Auto-generated profile, based on publicly available information

Pierre-Allain Duvillard

Université Grenoble Alpes Université Savoie Mont‐Blanc CNRS UMR 5204 EDYTEM Le Bourget‐du‐Lac France

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 November 2018 in Journal of Geophysical Research: Solid Earth
Verified
Journal Article
Open access
PDF file
PDP. A. Duvillard
P. A. Duvillard
Andre REVILAndre REVIL
Andre REVIL
YQY. Qi
Y. Qi
AAA. Soueid Ahmed
A. Soueid Ahmed
ACA. Coperey
A. Coperey
LRL. Ravanel
L. Ravanel
Three‐dimensional electrical resistivity and induced polarization data were collected on an unstable Alpine rock glacier in Val Thorens (Vanoise massif, France). In addition to these field data, we also performed induced polarization measurements during freeze and thaw using a soil sample and the poorly mineralized water, both from this site. In the tomograms, the electrical conductivity and the normalized chargeability show very distinctly the presence of the rock ice mixture. The chargeability itself is however quite constant over the entire investigated area with the exception of a small area associated with the presence of carboniferous rocks rich in graphite. The background chargeability is close to the dimensionless number R = 8 × 10−2, which is consistent with the prediction of the dynamic Stern layer model for the polarization of porous media. The theory implies that this dimensionless number R is independent on saturation and temperature in agreement with field observations. A main implication of this observation is that the classical Archie's law cannot be applied to describe the electrical conductivity in this type of environments with poorly mineralized pore water. Surface conductivity dominates the measured conductivity of the materials implying in turn that the electrical conductivity is related to both the water content and cation exchange capacity of the material. We propose new equations for both the electric conductivity and the normalized chargeability in this type of environments.

11 February 2019 in Regional Environmental Change
Verified
Journal Article
Closed access
PDF file
PDPierre-Allain Duvillard
Pierre-Allain Duvillard
LRLudovic Ravanel
Ludovic Ravanel
MMMarco Marcer
Marco Marcer
PSPhilippe Schoeneich
Philippe Schoeneich

15 May 2019 in Journal of Geophysical Research: Solid Earth
Verified
Journal Article
Open access
PDF file
ACA. Coperey
A. Coperey
Andre REVILAndre REVIL
Andre REVIL
FAF. Abdulsamad
F. Abdulsamad
BSB. Stutz
B. Stutz
PDP. A. Duvillard
P. A. Duvillard
LRL. Ravanel
L. Ravanel
We investigate the thermal dependence of the complex conductivity of nine porous materials in the temperature range +20 °C to −10 or −15 °C. The selected samples include three soils, two granites, three clay‐sands mixes, and one graphitic tight sandstone. A total of 12 experiments is conducted with one sample tested at three different salinities. Our goal is to use this database to extend the dynamic Stern layer polarization model in freezing conditions. We observe two polarization mechanisms, one associated with the effect of the change in the liquid water content and its salinity upon the polarization of the porous material. A second mechanism, at higher frequencies (>10 Hz), is likely associated with the polarization of ice. At low frequencies and above the freezing point, the in‐phase and quadrature conductivities depend on temperature in a predictable way. This dependence is due to the dependence of the mobility of the charge carriers with temperature. Below the freezing point, the in‐phase and quadrature conductivity follow a brutal decay with temperature. This dependence is modeled through an exponential freezing curve function. We were also able to determine how the (apparent) formation factor and surface conductivity change with temperature and water content below the freezing point. Our model is able to replicate the data at low frequencies and predicts correctly the fact that the ratio between the normalized chargeability and the surface conductivity is independent of the water content and temperature and equals a well‐defined dimensionless number R.

1 January 2020 in Permafrost and Periglacial Processes
Verified
Journal Article
Closed access
PDF file
MMMarco Marcer
Marco Marcer
SNSteffen Ringsø Nielsen
Steffen Ringsø Nielsen
CRCharles Ribeyre
Charles Ribeyre
MKMario Kummert
Mario Kummert
PDPierre‐Allain Duvillard
Pierre‐Allain Duvillard
KGKim Genuite
Kim Genuite

22 August 2019 in Journal of Geophysical Research: Solid Earth
Verified
Journal Article
Closed access
FAF. Abdulsamad
F. Abdulsamad
Andre REVILAndre REVIL
Andre REVIL
AGAhmad Ghorbani
Ahmad Ghorbani
VTV. Toy
V. Toy
MKM. Kirilova
M. Kirilova
LRL. Ravanel
L. Ravanel

11 July 2018 in Land Degradation & Development
Verified
Journal Article
Closed access
PDF file
LRLudovic Ravanel
Ludovic Ravanel
PDPierre‐Allain Duvillard
Pierre‐Allain Duvillard
Michel JaboyedoffMichel Jaboyedoff
Michel Jaboyedoff
CLChristophe Lambiel
Christophe Lambiel