28 January 2025 in ACS Sensors
12 March 2024 in IEEE Sensors Journal
Prolonged use of electronic devices, especially with incorrect sitting and posture, may cause changes in spinal shape. These issues can affect the distribution of pressure on the soles of the feet. As postural diseases continue to rise in prevalence, wearable wireless plantar pressure monitoring is essential. This paper proposed a wearable plantar pressure antenna sensor based on electromagnetic bandgap (EBG) array operating in the 2.45 GHz Industrial, Scientific and Medical (ISM) band. To measure the pressure, the antenna sensor adopts a dual-substrate structure whose gap is filled with foam. Applying pressure to the antenna will cause the gap to shrink, resulting in shifts of the antenna’s resonant frequency. By remotely reading the resonant frequency, wireless monitoring of plantar pressure can be achieved. The sensitivity of the antenna sensor to pressure is 1.06 MHz/N. In the two separate h ranges of 4.5 mm – 3.25 mm and 3 mm – 1.5 mm, the 2 × 2 Electromagnetic Bandgap (EBG) array can increase the sensitivity of the antenna sensor by 35.4% and 39.3%, respectively. In addition, the EBG array can also reduce the specific absorption rate (SAR) of the antenna by approximately 95% and increase the gain from -0.8 dB to 6.6 dB. The simulated and measured results of the antenna sensor produced a good agreement.
17 February 2025 in Sensors and Actuators B: Chemical
11 November 2024 in International Journal of Microwave and Wireless Technologies
In this paper, a capsule endoscopy system with a sensing function is proposed for medical devices. A single-arm spiral antenna is designed for data transmission and is combined with the voltage controlled oscillator to achieve sensing capabilities. The designed antenna operates at a 900 MHz industrial scientific medical band. By establishing a three-layer cylindrical model of the stomach, it was concluded that the antenna in the stomach has a high peak gain of −1.1 dBi. Additionally, the antenna achieved a −10 dB impedance bandwidth of 5%. The capsule endoscopy was experimentally measured in both actual stomach and simulated environments. The maximum working distance of the capsule endoscope was measured to be 6.8 m. Additionally, the proposed capsule endoscope was tested for its sensing function using solutions with different dielectric constants. Finally, it was confirmed through link analysis that it has good communication capabilities. The results and analysis confirm that the proposed capsule endoscope can be used for examining gastric diseases.