Daniel Pajek

Daniel Pajek

Auto-generated profile, based on publicly available information

Daniel Pajek

Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada; Department of Medical Biophysics, University of Toronto, Toronto, Canada

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2014 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
DPDaniel Pajek
Daniel Pajek
ABAlison Burgess
Alison Burgess
YHYuexi Huang
Yuexi Huang
KHKullervo Hynynen
Kullervo Hynynen

17 July 2012 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
DPDaniel Pajek
Daniel Pajek
KHKullervo Hynynen
Kullervo Hynynen
High intensity focused ultrasound (HIFU) is capable of mechanically disintegrating blood clots at high pressures. Safe thrombolysis may require frequencies higher than those currently utilized by transcranial HIFU. Since the attenuation and focal distortion of ultrasound in bone increases at higher frequencies, resulting focal pressures are diminished. This study investigated the feasibility of using transcranial HIFU for the non-invasive treatment of ischemic stroke. The use of large aperture, 1.1-1.5 MHz phased arrays in targeting four clinically relevant vessel locations was simulated. Resulting focal sizes decreased with frequency, producing a maximum -3 dB depth of field and lateral width of 2.0 and 1.2 mm, respectively. Mean focal gains above an order of magnitude were observed in three of four targets and transducer intensities required to achieve thrombolysis were determined. Required transducer element counts are about an order of magnitude higher than what currently exists and so, although technically feasible, new arrays would need to be developed to realize this as a treatment modality for stroke.

19 November 2013 in Medical Physics
Verified
Journal Article
Open access
DPDaniel Pajek
Daniel Pajek
Kullervo HynynenKullervo Hynynen
Kullervo Hynynen
Purpose:: Transcranial focused ultrasound is an emerging therapeutic modality that can be used to perform noninvasive neurosurgical procedures. The current clinical transcranial phased array operates at 650 kHz, however the development of a higher frequency array would enable more precision, while reducing the risk of standing waves. However, the smaller wavelength and the skullˈs increased distortion at this frequency are problematic. It would require an order of magnitude more elements to create such an array. Random sparse arrays enable steering of a therapeutic array with fewer elements. However, the tradeoffs inherent in the use of sparsity in a transcranial phased array have not been systematically investigated and so the objective of this simulation study is to investigate the effect of sparsity on transcranial arrays at a frequency of 1.5 MHz that provides small focal spots for precise exposure control.Methods:: Transcranial sonication simulations were conducted using a multilayer Rayleigh‐Sommerfeld propagation model. Element size and element population were varied and the phased arrayˈs ability to steer was assessed.Results:: The focal pressures decreased proportionally as elements were removed. However, off‐focus hotspots were generated if a high degree of steering was attempted with very sparse arrays. A phased array consisting of 1588 elements 3 mm in size, a 10% population, was appropriate for steering up to 4 cm in all directions. However, a higher element population would be required if near‐skull sonication is desired.Conclusions:: This study demonstrated that the development of a sparse, hemispherical array at 1.5 MHz could enable more precision in therapies that utilize lower intensity sonications.

1 January 2012 in Acoustics Today
Verified
Journal Article
Closed access
DPDaniel Pajek
Daniel Pajek
KHKullervo Hynynen
Kullervo Hynynen

1 November 2013 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
Kullervo HynynenKullervo Hynynen
Kullervo Hynynen
ABAlison Burgess
Alison Burgess
MOMeaghan M. O’reilly
Meaghan M. O’reilly
RARyan Alkins
Ryan Alkins
DPDaniel Pajek
Daniel Pajek
AHAlec Hughes
Alec Hughes